Calibration Certificate Issuance

1.Calibration Documents

Documents Certifying Instrument Traceability

If you require documents certifying the traceability of a measuring instrument, a set of three documents is applicable: an inspection certificate, a calibration certificate, and a traceability diagram.

Approach to inspection certificates and related accuracy guarantee

At Hioki, we ensure product quality through design verification during development and process control during production. The inspection certificate lists representative inspection items, but may not include every point a customer requests. Even in such cases, if the overall judgment is marked as “PASS,” the product meets all specified accuracy requirements for its full range, so no additional designation of inspection points is required.

Accuracy guarantee when using multiple products together

When using two or more products together (for example, a power meter and a clamp sensor), an overall judgment of “PASS” on each product’s inspection certificate indicates that the combined accuracy (the sum of each product’s accuracy) is guaranteed. Even without calibrating the combination as a set, individual calibration of each product ensures that the combination continues to meet accuracy specifications.

2.Available Documents

From October 1, 2025, the formats of calibration certificate and traceability chart have been updated, and both Japanese and English versions now use the same standardized format. For further details, please click here.

Test ReportSample(Japanese, English) (*1) PDF
  • *1:The calibration result value with "####..." in the inspection report is abnormal data like the out of the measurement range, etc.
Calibration CertificateSample(Japanese, English)PDF
Traceability Chart
Traceability Chart (overall)
  • Download available from here.
Standard calibration data set (Japanese only) Included documents:
  • Reference standard calibration data (*2) (Calibration documentation for Hioki’s primary standards traceable to external organizations’standards)
  • Intermediate standard calibration data (*3) (Calibration data of standards positioned between the utilized standards and the reference standards)
  • Utilized standard calibration data(Calibration data of standards used to calibrate Hioki products)
  • *2: Some reference standard calibration data may be obtained through general calibration procedure.
  • *3: Some products may not have intermediate standard calibration data.
Utilized standard calibration data (Japanese only)Calibration data of standards used to calibrate Hioki products
ISO/IEC17025(JCSS)Calibration CertificateSample(English)PDF

3. Provision Method

-1. Test Report, Calibration Certificate, Traceability Chart(Calibration Equipment)

The method of provision varies depending on whether the product is eligible for download or not.

Provision Method
Newly Purchased Products (Eligible for calibration document download)Download is available only from the website. For download procedures, please click here.
Newly Purchased Products (Not eligible for calibration document download) Please select one of the following options when placing your order.
a. Calibration documents "Set of three documents" (*4) will be provided in paper form (free of charge) (*5)
b. Calibration documents "Not included"
Repaired or Calibrated Products (Eligible for calibration document download)Download is available only from the website. For download procedures, please click here.
Repaired or Calibrated Products (Not eligible for calibration document download) Calibration documents "Set of three documents" (*4) will be provided in paper format (free of charge) (*5)

*4: From May 1, 2026, all calibration documents are provided as a "Set of Three Documents" (Calibration Certificate, Traceability Chart, and Test Report). Individual orders will no longer be accepted.

*5: Customer name and customer record number are not indicated on the calibration documentation for general calibration documents.Learn more.

Note

  • There are some products for which only the test report will be issued.
  • For products not eligible for calibration document download, issuance after delivery is available if requested within the specified period below. In such cases, a set of three calibration documents will be issued for a fee. However, please note that issuance may not be possible for certain products. For further details, please contact us.
    • Newly purchased products: Within 15 months from the production month
    • Repaired or calibrated products: Within 15 months from the calibration date
  • If you require printed calibration documents for products eligible for download, please contact us separately.

-2. Traceability Chart (overall)

As of May 1, 2026, the issuance of printed traceability chart (overall) has been discontinued. Please download from the link below.

JapanesePDF / EnglishPDF

-3. Other Documents

The following calibration documents can be issued in paper form for a fee. Please place an order if required.

  • Utilized standard calibration data (Japanese only)
  • ISO/IEC 17025 (JCSS) calibration certificates
  • Documents for products with a verification number label instead of a serial number label.
    Example:“21H000”
  • Custom-made calibration documents

4. Download Procedure (free)

After receiving the product, customers can download the calibration documents of the applicable product, free of charge.

Applicable Products

Applicable Calibration Documents

  • Test Report
  • Calibration Certificate
  • Traceability Chart(Calibration Equipment)

Service Capability Period

Within 5 years from the calibration date.

Download Procedure

my HIOKI

If you cannot download calibration certificate issuance, please verify the following:

  • Your device is authorized to download from the following sites
    https://cloud.gennect.net/
  • You use a supported browser for the Gennect Download Portal (Gennect Cloud)