GENNECT ONE SF4000
Get Results from the Job Site in Real-Time & Capture Data on the PC while Testing Remotely
GENNECT ONE is a free PC software for Windows operating systems that lets you log data in real-time, import data and files, configure instrument settings, export native data as a CSV file and create reports with select Hioki measuring instruments.
Remote measurement is also possible by connecting to the GENNECT Cloud.
GENNECT ONE Special WEB site
A special website introducing the charm of GENNECT ONE has been released.
We will continue to provide useful information such as functions, application examples, and technical information in the field.
Key Features
- Connect measuring instruments to a PC via a LAN cable
- Acquire measurement values from multiple measuring instruments at regular intervals and display them on a graph in real time. (*1)
- Lay out measurement values on the image and able to check graphically (*1)
- Operate measuring instruments connected via LAN from a PC (*2)
- Automatically transfer files saved on a LAN-connected measuring instrument to a PC (*3)
- List MAX, MIN and AVG values (Display time of MAX & MIN data)
- Real-time calculation of measurement values of arbitrary measurement items (calculation between channels)
- Automatically output measurement data to daily/weekly/monthly report or CSV file
- Enable remote measurement by connecting to GENNECT Cloud
- *1:Max. number of connections: 30 units, The measurement value (current location) displayed by the instrument is acquired at a fixed interval (minimum 1 second) by the PC timer.
- *2:Max. number of connections: 30 units
- *3:Max. number of connections: 15 units.
Model No. (Order Code)
SF4000 | Application for Windows |
---|
Enable remote measurement by connecting to GENNECT Cloud
You can connect GENNECT One to GENNECT Cloud, the cloud service designed specifically for Hioki's GENNECT series. Users can access GENNECT One via GENNECT Cloud anytime, from anywhere.
Integration with GENNECT Cloud
Functions | - Upload measurement data on the local PC to the cloud for sharing and management - Receive measurement values from remotely connected instruments, retrieve instrument data files, or control instruments remotely(*1) (Remote measurement mode) - Upload threshold information of battery testers BT3554, BT3554-01, BT3554-50 and profile information of BT3554-50 to the cloud for sharing and management (*2) (*1) Remote instrument control is only available with the Standard/Pro plans of GENNECT Cloud. (*2) Available only with GENNECT Cloud's Standard/Pro plans. |
---|---|
Storage size | Trial: 512MB, Free: 5GB, Standard: 50GB, Pro: 500GB |
Supported models (Remote measurement mode) |
PQ3100, PQ3198, PW3335, PW3336, PW3337, PW3360, PW3365, PW3390, PW6001, PW8001, LR8410, LR8416, LR8450, LR8450-01, MR6000 (*1) LR8410 and LR8416 do not support remote control via cloud. (*2) PW3335, PW3336, PW3337, PW3390, and PW6001 do not support data file downloading in remote measurement mode. |
Max. number of units that can be connected (Remote measurement mode) |
Trial: 1 unit, Free: 3 units, Standard: 8 units, Pro: 8 units |
Max. number of channels selectable per unit (Remote measurement mode) |
Trial: 10, Free: 30, Standard: 30, Pro: 100 |
Logging
Functions | • Generate monitor, graph, and list displays of measured values from LAN-connected instruments in real time. * • Real-time calculation of measurement values of arbitrary measurement items (calculation between channels) • Automatically output measurement data to daily/weekly/monthly report or CSV file * Acquire measured values (current values) displayed on instruments at a set interval (as short as 1 sec.) using the computer’s timer. * Max. 32 items when simultaneously displaying graphs |
|||||
---|---|---|---|---|---|---|
Logging intervals | 1, 2, 5, 10, 30 sec. 1, 2, 5, 10, 30 min. 1 hour |
|||||
Measured parameters | • PW8001, PW6001, PW3390: Basic Measurement items, Harmonic measurement items (Instantaneous value per interval) • PW3335, PW3336, PW3337: Basic Measurement items (Instantaneous value per interval) • PQ3100, PQ3198, PW3365, PW3360: Voltage, Current, Power (Instantaneous value per interval, MAX, MIN, AVE values between intervals) • LR8400, LR8401, LR8402, LR8410, LR8450, LR8450-01, MR6000: Various measurement items such as Temperature, Analog input, etc. (Instantaneous value per interval) • Calculation between channels (up to 16 items) |
|||||
Number of items able to monitor and log | Max. 512 items + 16 items (calculation between channels) | |||||
Recording time | Recording time: Continuous measurement,set time File segmentation: 1 day, 1 hour Logging stops when the storage capacity of the PC is below 512 MB |
|||||
Max. number of connections | 30 units |
Dashboard
Functions | • Monitor measured values in real time from LAN-connected instruments.* • Display alarms in real time when a measured value exceeds a threshold.* • Display measured values on a user-selected image. • Real-time calculation of measurement values of arbitrary measurement items (calculation between channels) • Automatically output measurement data to daily/weekly/monthly report or CSV file * Acquire measured values (current values) displayed on instruments at a set interval (as short as 1 sec.) according to the computer’s timer. |
|||||
---|---|---|---|---|---|---|
Monitoring intervals | 1, 2, 5, 10, 30 sec. 1, 2, 5, 10, 30 min. 1 hour |
|||||
Measured parameters | • PW8001, PW6001, PW3390: Basic Measurement items, Harmonic measurement items (Instantaneous value per interval) • PW3335, PW3336, PW3337: Basic Measurement items (Instantaneous value per interval) • PQ3100, PQ3198, PW3365, PW3360: Voltage, Current, Power (Instantaneous value per interval, MAX, MIN, AVE values between intervals) • LR8400, LR8401, LR8402, LR8410, LR8450, LR8450-01, MR6000: Various measurement items such as Temperature, Analog input, etc. (Instantaneous value per interval) • Calculation between channels (up to 16 items) |
|||||
Number of stored parameters | Max. 512 items + 16 items (calculation between channels) | |||||
Recording time | Recording time: Continuous measurement File segmentation: 1 day, 1 hour Logging stops when the storage capacity of the PC is below 512 MB |
|||||
Max. number of connections | 30 units |
Remote control
Functions | Control LAN-connected instruments from a computer | |||||
---|---|---|---|---|---|---|
Number of simultaneous operation | 30 unit at a time |
File transfer (Manual)
Interface | LAN, USB (USB only for BT3554-50, BT3554, 3554) | |||||
---|---|---|---|---|---|---|
Functions | Acquire files stored in LAN-connected instruments from a PC The BT3554-50 series can be acquired via USB. |
|||||
Compatible instruments | PQ3100, PQ3198, PW3360, PW3365, PW3390, PW6001, PW8001, LR8400, LR8401, LR8402, LR8410, LR8416, LR8450, LR8450-01, MR6000, BT3554-50, BT3554, 3554 |
|||||
Number of simultaneous operation | 1 unit at a time |
File transfer (Automatic)
Functions | Automatically send files saved by LAN-connected instruments to a computer. |
---|---|
Compatible instruments | PQ3100, PQ3198, PW3360, PW3365, PW8001, LR8400, LR8401, LR8402, LR8410, LR8416, LR8450, LR8450-01, MR6000 |
Max. number of connections | 15 units |
Other functions
Files loading | • Data file obtained by GENNECT Cross for iOS/Android *Logging, General Measurement, image and battery formats only *No direct Bluetooth® connection is possible, please use the smartphone app for Bluetooth® data collection • Data file obtained by GENNECT Remote • Measurement data folder (PQ3100, PQ3198, PW3360, PW3365) • Measurement data file (LR8400 series, LR8410, LR8416, LR8450, MR6000, LR5000 series, PW3390, PW6001, PW8001) |
|||||
---|---|---|---|---|---|---|
Instrument clock synchronization |
Set the clocks of measuring instruments connected via LAN to the PC (manual, automatic) | |||||
CSV output | Logging data, time-series measurement data, waveform files of instruments supporting time-series viewer, data files acquired by GENNECT Cross (standard measurement, battery) | |||||
Report creation | PDF, Word and Excel formats |
System requirements
Supported operating systems | Windows 10 (32bit / 64bit) Windows 11 |
|||||
---|---|---|---|---|---|---|
Software environment | Microsoft .NET Framework 4.6.2 or later | |||||
CPU | Clock speed: 2 GHz or greater | |||||
RAM | 4 GB or more | |||||
Display | 1366 × 768 or better resolution | |||||
Hard drive | 1 GB or more available space |
LAN : Logging, Dashboard, Clock synchronization(Auto/Manual), Remote control,File Acquisition(Manual), File transfer(Auto) (9)
Last update: June 2020 (Support devices will be added sequentially!)