GENNECT ONE SF4000

Get Results from the Job Site in Real-Time & Capture Data on the PC while Testing Remotely

GENNECT ONE is a free PC software for Windows operating systems that lets you log data in real-time, import data and files, configure instrument settings, export native data as a CSV file and create reports with select Hioki measuring instruments.

GENNECT ONE Special WEB site

A special website introducing the charm of GENNECT ONE has been released.
We will continue to provide useful information such as functions, application examples, and technical information in the field.

Click here for GENNECT ONE special site

Key Features

  • Connect measuring instruments to a PC via a LAN cable (*1)
  • Display acquired data as graphs and simultaneously monitor all data in real-time (*2)

  • Monitor display that indicates measured values in real time (*2)
  • Operate measuring instruments connected via LAN from a PC
  • Automatically transfer files saved on a LAN-connected measuring instrument to a PC
  • List MAX, MIN and AVG values (Display time of MAX & MIN data)
  • Real-time calculation of measurement values of arbitrary measurement items (calculation between channels)
  • Automatically output measurement data to daily report or CSV file
  • *1:Operation guaranteed for up to 15 units. Please contact your nearest Hioki distributor for connections exceeding 15.
  • *2:The measured value (present value) displayed by the measuring instrument is obtained at a certain interval (minimum 1s interval) according to the timer on the PC.

Model No. (Order Code)

SF4000 Application for Windows

Logging

Functions • Generate graph and list displays of measured values from LAN-connected instruments in real time. *
• Real-time calculation of measurement values of arbitrary measurement items (calculation between channels)
• Automatically output measurement data to daily report or CSV file

* Acquire measured values (current values) displayed on instruments at a set interval (as short as 1 sec.) using the computer’s timer.
Logging intervals 1, 2, 5, 10, 30 sec.
1, 2, 5, 10, 30 min.
1 hour
Measured parameters • PW6001, PW3390: Basic Measurement items, Harmonic measurement items (Instantaneous value per interval)
• PQ3100, PQ3198, PW3365, PW3360: Voltage, Current, Power (Instantaneous value per interval, MAX, MIN, AVE values between intervals)
• LR8400, LR8401, LR8402, LR8410, LR8450, LR8450-01, MR6000: Various measurement items such as Temperature, Analog input, etc. (Instantaneous value per interval)
• Calculation between channels (up to 16 items)
Number of items able to monitor and log Max. 512 items + 16 items (calculation between channels)

* Max. 32 items when simultaneously displaying graphs
Recording time Recording time: Continuous measurement,set time
File segmentation: 1 day, 1 hour
Stop logging when the storage capacity of the PC drops below 512 MB

Dashboard

Functions • Monitor measured values in real time from LAN-connected instruments.*
• Display alarms in real time when a measured value exceeds a threshold.*
• Display measured values on a user-selected image.
• Real-time calculation of measurement values of arbitrary measurement items (calculation between channels)
• Automatically output measurement data to daily report or CSV file

* Acquire measured values (current values) displayed on instruments at a set interval (as short as 1 sec.) according to the computer’s timer.
Monitoring intervals 1, 2, 5, 10, 30 sec.
1, 2, 5, 10, 30 min.
1 hour
Measured parameters • PW6001, PW3390: Basic Measurement items, Harmonic measurement items (Instantaneous value per interval)
• PQ3100, PQ3198, PW3365, PW3360: Voltage, Current, Power (Instantaneous value per interval, MAX, MIN, AVE values between intervals)
• LR8400, LR8401, LR8402, LR8410, LR8450, LR8450-01, MR6000: Various measurement items such as Temperature, Analog input, etc. (Instantaneous value per interval)
• Calculation between channels (up to 16 items)
Number of measured parameters Max. 512 items + 16 items (calculation between channels)
Recording time Recording time: Continuous measurement
File segmentation: 1 day, 1 hour
Stop logging when the storage capacity of the PC drops below 512 MB

Remote control

Functions Control LAN-connected instruments from a computer
Number of simultaneous operation 1 unit at a time

File transfer (Manual)

Interface LAN, USB (USB only for BT3554-50, BT3554, 3554)
Functions Acquire files stored in LAN-connected instruments from a PC
The BT3554-50 series can be acquired via USB.
Compatible instruments PQ3100, PQ3198, PW3360, PW3365, PW3390, PW6001,
LR8400, LR8401, LR8402, LR8410, LR8416, LR8450, LR8450-01, MR6000, BT3554-50, BT3554, 3554

File transfer (Automatic)

Functions Automatically send files saved by LAN-connected instruments to a computer.
Compatible instruments PQ3100, PQ3198, PW3360, PW3365, LR8400, LR8401, LR8402, LR8410, LR8416, LR8450, LR8450-01, MR6000

Other functions

Files loading • Data file obtained by GENNECT Cross for iOS/Android
*Logging, General Measurement, image and battery formats only
*No direct Bluetooth® connection is possible, please use the smartphone app for Bluetooth® data collection
• Data file obtained by GENNECT Remote SF4101, SF4102
• Measurement data folder (PQ3100, PQ3198, PW3360, PW3365)
• Measurement data file (LR8400 series, LR8410, LR8416, LR8450, MR6000, LR5000 series)
Instrument clock
synchronization
Set the clocks of measuring instruments connected via LAN to the PC (manual, automatic)
CSV output Output 512 + 16 items at once (logging function, dashboard function)
Report creation PDF, Word and Excel formats

System requirements

Supported operating systems Windows 7 (32bit / 64bit)
Windows 8.1 (32bit / 64bit)
Windows 10 (32bit / 64bit)
Software environment Microsoft .NET Framework 4.6.2 or later
CPU Clock speed: 2 GHz or greater
RAM 4 GB or more
Display 1366 × 768 or better resolution
Hard drive 1 GB or more available space

Compatible products A (8)

Compatible products C (0)

Models whose data can be loaded (via USB), Clock synchronization (USB)