CLAMP ON SENSOR 9272-05
Ideal for Measuring AC Current with Low Frequencies such as Inverter Control Devices
Hioki current sensors are best-in-class devices for use with power meters, Memory HiCorders and high performance oscilloscopes. The 9272-10/9272-05 are a 1 Hz to 100 kHz AC current sensor ideal for measuring low frequency equipment such as inverters.
CAT III 600 V
Use with an instrument with a high input impedance of 1 MΩ or higher.
Key Features
- Superior low frequency and phase characteristics suitable for testing the current and power of inverter control devices
- Wide 1 Hz to 100 kHz frequency bandwidth perfect for harmonic analysis, FFT analysis and waveform monitoring (AC only)
Model No. (Order Code)
9272-05 | 20/200 A AC, ME15W terminal |
---|---|
9272-10 | Discontinued, 20/200 A AC, PL23 terminal |
Basic specifications
Rated current | 20 A AC, or 200 A AC (selectable) | |||||
---|---|---|---|---|---|---|
Max. allowable input | 50 A rms (at 20 A range), 300 A rms (at 200 A range) | |||||
Frequency characteristics | 1 Hz (±2 % rdg. ±0.1 % f.s.) to 100 kHz (±30 % rdg. ±0.1 % f.s.) | |||||
Amplitude and Phase accuracy | Amplitude: ±0.3 % rdg. ±0.01 % f.s. Phase: ±0.2 ° (45 to 66 Hz) | |||||
Output voltage | 2 V/20 A or 2 V/200 A (This device outputs AC voltage via the Sensor Unit) |
|||||
Max. rated voltage to earth | 600 V rms (CAT III) | |||||
Core diameter | φ 46 mm (1.81 in) | |||||
Power supply | Power suppled via the Power Analyzer PW8001, PW6001, PW3390, Sensor Unit CT9555, CT9556, CT9557, or 3CH CURRENT UNIT U8977 | |||||
Power consumption | 5 VA Max. (when measuring 200 A) | |||||
Dimensions and mass | 78 mm (3.07 in) W × 188 mm (7.40 in) H × 35 mm (1.38 in) D, 430 g (15.2 oz), cord length: 3 m (9.84 ft) | |||||
Included accessories | Carrying case 9355 ×1, Instruction manual ×1, Mark bands ×6 |
Compatible models
Compatible models | 9272-10 (Discontinued product) | 9272-05 | ||||
---|---|---|---|---|---|---|
Power Analyzer PW3390 | △ (Requires CT9900) | OK | ||||
Power Analyzer 3390 | OK | △ (Requires CT9901) | ||||
Power HiTester 3193 series | OK | △ (Requires CT9901) | ||||
Current Unit 8971 | △ (Requires the 9318) | △ (Requires the 9318, CT9901) | ||||
F/V Unit 8940 | △ (Requires the 9318, 9705) | △ (Requires the 9318, 9705, CT9901) | ||||
3CH Current Unit U8977 | △ (Requires the CT9900) | OK |
Bundled accessories (1)
Options A (5)
Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length
Cord has metallic BNC connectors at both ends, use at metallic terminal, 1.5 m (4.92 ft) length
Options B (1)
Cannot be used in combination with the 9277, 9278, 9279
Convert PL23 (10-pin) terminal to ME15W (12-pin) terminal
Options C (2)
The CT9902 connects up to 2 cables in series (Accuracy addition required)
ME15W (12 pin) to PL23 (10 pin) connector
5 m (16.41 ft) length, ME15W (12 pin) - ME15W (12 pin) connector
Options D (1)
*The Clamp Sensor 9272-10 has different output wiring than the previous 9272. Both the 9318 and 9705 are required in order to connect to the F/V Unit 8940.
To connect the CT6841-6846, CT6865/63/62, 9709, 9272-10 to the 8971/40/51, 38 cm (14.96 in) length
- Versatile Instrument for Various UPS Operational Tests
- Comprehensive Evaluation of Inverter Motors
- Evaluation of Input and Output Characteristics of Inverters
- Testing System Interconnection Protection Function of Power Conditioners
- Evaluation of Input and Output Characteristics of Power Conditioners