Difference of average values between two clamp on meters

QI got different average values between the 3285 and CM4374.

A

The AVG value of the 3285 Clamp On HiTester is calculated using "(MAX value + MIN value)/2" as soon as REC starts. On the other hand the CM4370 AC/DC Clamp Meter series displays the average value of all measurement data obtained as soon as measurement starts.


[Applicable models]
3281, 3282, 3283, 3284, 3285, CM4371, CM4372, CM4373, CM4374, CM4375, CM4376, CM4141, CM4142