AC/DC CLAMP METER
CM4373
True RMS 2000 A AC/DC Clamp Meter for the Toughest Situations
Hioki clamp meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. The CM4373 is a 2000A True RMS clamp meter that features stronger jaws, broader -25℃ to 65℃ operating temperature range and IP54 dustproof and waterproof enclosure to enable professionals to work quickly in tough situations including the development, repair, and maintenance of equipment and devices such as electric vehicles. Additionally, the high-voltage DC measurement capability of up to 1700 V is ideal for the clamp maintenance inspections of electrical and solar power equipment. CAT IV 600 V, CAT III 1000 V
| CM4373 |
|---|
• Multiple measurement functions such as current, voltage, resistance, frequency, and voltage detection • Simultaneously measure inrush current in RMS and crest values • Damage-resistant jaws (current sensor) provide even more years of reliable use. • Expanded -25 °C to 65 °C operating temperature range • IP54 dustproof and waterproof enclosure *Jaws (current sensor portion): IP50 • Automatic AC/DC function helps boost work efficiency • Remain alert to hazards with a red backlight and beeping tone • Measure DC voltages of up to 1700 V
The Auto Hold feature is perfect in situations where the display is hard to read because the clamped wires are in hard to reach locations. With Auto Hold, measured results automatically freeze on the display until the next measurement starts, making testing and record taking a snap.
The tip of the current sensor of the CM4370 Series can also detect live voltages, eliminating the need for you to use a separate voltage detector. Energized lines are identified with a loud buzzer and red LED on the clamp meter.
| DC Current range | 600.0 A/2000 A, Basic accuracy: ±1.3% rdg. ±0.3 A (600 A range) |
|---|---|
| AC Current range | 600.0 A/2000 A (10 Hz to 1 kHz, True RMS), Basic accuracy: ±1.3% rdg. ±0.3 A (at 600 A) |
| Crest factor | 600.0 A range: 3 or less, 2000 A range: 2.84 or less |
| DC+AC Current range | 600.0 A/2000 A (10 Hz to 1 kHz, True RMS), Basic accuracy: ±1.3% rdg. ±1.3 A (at 600 A) |
| DC Voltage range | 600.0 mV to 1500 V, 5 ranges, Basic accuracy: ±0.5% rdg. ±3 dgt. |
| AC Voltage range | 6.000 V to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy: ±0.9% rdg. ±3 dgt. |
| DC+AC Voltage range | 6.000 V to 1000 V, 4 ranges, Basic accuracy: ±1.0% rdg. ±7 dgt. |
| Resistance range | 600.0 Ω to 600.0 kΩ, 4 ranges, Basic accuracy: ±0.7% rdg. ±5 dgt. |
| Capacitance range | 1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±5 dgt. |
| Frequency range | 9.999 Hz to 999.9 Hz, Basic accuracy: ±0.1% rdg. ±1 dgt. |
| Temperature (K) | -40.0 to 400.0 ˚C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0 ˚C |
| Voltage detection | Hi: 40 V to 600 V AC, Lo: 80 V to 600 V AC, 50/60 Hz |
| Other functions | Automatic AC/DC detection, Plus/Minus judgement function of DC A, DC V, Max/Min/Average/PEAK MAX/ PEAK MIN value display, Filter function, Display value hold, Auto hold, Back light, Auto-power save, Buzzer sounds, Zero-adjustment |
| Dustproof, waterproof | Grip: IP54 (when measuring an insulated conductor only), Jaw (the current sensor portion of the instrument)/ barrier: IP50 *Risk of electric shock from the conductor being measured increases when wet. |
| Power supply | LR03 Alkaline battery ×2, Continuous use 45 hr (Backlight OFF) |
| Core jaw diameter | 92 mm (3.62 in) W×18 mm (0.71 in) D, φ55 mm (2.17 in) |
| Dimensions and mass | 65 mm (2.56 in) W×250 mm (9.84 in) H×35 mm (1.38 in) D mm, 530 g (18.7 oz) |
| Accessories | TEST LEAD L9207-10, CARRYING CASE C0203, LR03 Alkaline battery ×2, Instruction Manual×1 |
Log into your myHioki account to access more technical documents and information where available.
| No results were found. |
|
|
Nov 6, 2019 - Nov 8, 2019 | |
|
|
Sep 18, 2019 - Sep 20, 2019 | |
|
|
May 29, 2019 - May 31, 2019 |
| Catalog: CLAMP ON HiTESTER Series | Download PDF [3MB] |
English |
| Catalog: AC/DC CLAMP METER AC CLAMP METER CM4000 series | Download PDF [6MB] |
English |
| No results were found. |
If you can not download, log into your myHioki account to access more technical documents and information where available.
| Instruction Manual |
English |
Ver.03 | |
| Instruction Manual |
Korean |
Ver.01 | |
| Instruction Manual |
English Spanish German French |
Ver.01 | |
| Instruction Manual |
Simplified Chinese |
Ver.03 |
If you can not download, log into your myHioki account to access more technical documents and information where available.
|
AC/DC CLAMP METER CM4373,CM4373-20,CM4373-21,CM4373-30,CM4373-31,CM4373-40 [146KB] |
Ver.02 |
|
AC/DC CLAMP METER CM4371,CM4372,CM4373,CM4374 [110KB] |
Ver.04 |
| No results were found. |
| Flyer: Usable temperature range Max.65°C Max.-25°C | Download PDF [1MB] |
English |
Options for the L9207-10 (L9207-10 is a bundled accessory)
CONTACT PIN SET L4933
Attaches to the tip of the Test Lead L9207-10/DT4911, L9206, 60V DC/ 30V AC
SMALL ALLIGATOR CLIP SET L4934
Attaches to the tip of the L4932, L9207-10/DT4911, L9206, CAT III 300V, CAT II 600V
TEST LEAD L9207-10
90 cm (2.95 ft) length
Options for the L4930, Test Pin Set L4932 is required when using the Small Alligator Clip Set L4934
GRABBER CLIP 9243
Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V
CONNECTION CABLE SET L4930
1.2 m (3.94 ft) length
EXTENSION CABLE SET L4931
Expands the length of the cable with banana plug, 1.5 m (4.92 ft) length
TEST PIN SET L4932
Attaches to the tip of the banana plug cable, CAT IV 600V, CAT III 1000V
SMALL ALLIGATOR CLIP SET L4934
Attaches to the tip of the L4932, L9207-10/DT4911, L9206, CAT III 300V, CAT II 600V
ALLIGATOR CLIP SET L4935
Attaches to the tip of the banana plug cable, CAT IV 600V, CAT III 1000V
BUS BAR CLIP SET L4936
Attaches to the tip of the banana plug cable, CAT III 600V
MAGNETIC ADAPTER SET L4937
Attaches to the tip of the banana plug cable, CAT III 1000V
TEST PIN SET L4938
Attaches to the tip of the banana plug cable, CAT III 600V
BREAKER PIN SET L4939
Attaches to the tip of the banana plug cable, CAT III 600V
THERMOCOUPLES(K) DT4910
K type, tip exposed, 0.3 mm (0.01 in) diameter, 80 cm (2.62 ft) length, -40 to 260 °C (-40 to 500 °F), tolerance ±2.5 °C
Bundled accessory
CARRYING CASE C0203