NEW

AC CLAMP METER

CM4141

Innovative Current Sensor Design, Easily Get Into Tight Spaces

Hioki clamp on meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. The CM4141 is a 2000A AC True RMS clamp meter that features a uniquely designed slim jaw that lets you easily get into the narrow gaps between cables in crowded electrical distribution boxes without fear of damaging the cables or the clamp meter. The broad -25℃ to 65℃ operating temperature range and IP50 dustproof and waterproof enclosure to enable professionals to work quickly in crowded electrical distribution panels. The high current measurement capability makes it especially useful for industrial applications. CAT IV 600 V CAT III 1000 V Key Features • Easily get into tight spaces between cables thanks to thin sensor with a minimum cross-section span of 11 mm • Measure up to 2000 A AC • AC A, AC and DC V, DC+AC V, resistance, frequency, temperature, and more • Expanded -25 °C to 65 °C operating temperature range



Model No. (Order Code)

CM4141

For the latest information about countries and regions where wireless operation is currently supported, please visit the Hioki website.

Guarantee3years
TrueRMS
CE

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

AC Current range60.00 A to 2000 A, 3 ranges (45 Hz to 1 kHz, True RMS), Basic accuracy 45-66 Hz: ±1.5% rdg. ±0.08 A
Crest factorFor the 60.00 A range: 2.5 (greater than 50.00 A and less than or equal to 60.00 A) to 2000 A range: 1.5 (2000 A or less)
DC Voltage range600.0 mV to 1500 V, 5 ranges, Basic accuracy: ±0.5% rdg. ±0.5 mV (at 600 mV)
AC Voltage range6.000 V to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy 45-66 Hz: ±0.9% rdg. 0.003 V (at 6 V)
DC+AC Voltage range6.000 V to 1000 V, 4 ranges, Basic accuracy DC, 45-66 Hz: ±1.0% rdg. ±0.013 V (at 6 V)
Resistance range600.0 Ω to 600.0 kΩ, 4 ranges, Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)
Electrostatic capacity range1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)
Frequency rangeVoltage: 9.999 Hz to 999.9 Hz 3 ranges, Current: 99.99 Hz to 999.9 Hz 2 ranges, Basic accuracy: ±0.1% rdg. ±0.01 Hz (at 99.99 Hz)
Temperature (K)-40.0 to 400.0 ˚C, Basic accuracy: ±0.5% rdg. ±3.0 ˚C + temperature probe accuracy
Other functionsContinuity check, Diode check, Automatic AC/ DC detection (Voltage check only), Max/ Min/ AVG/ Peak waveform MAX/ Peak waveform MIN value display, Low-pass filter function, Display value hold, Backlight, Auto power save, Buzzer sound, Zero-adjustment, and other function
Dustproof, waterproofIP20 (Current measurement of voltage or hazardous live conductors under completely dry condition)
IP50 (When measuring or storing the resistance of a completely dry state or the current of an insulated conductor), However, dustproof and waterproof design equivalent to IP54 only on the handheld part and in a non-measurement state.
InterfaceN/A
Power supplyLR03 Alkaline battery ×2, Continuous use: 48 hr (Backlight OFF)
Core jaw diameterφ55 mm (2.17 in), Jaw dimension: 82 mm (3.23 in) W × 11 mm (0.43 in) D (D dimension is a range value of 44 mm (1.73 in) from the tip of the jaw)
Jaw cross-sectionMinimum dimension 11 mm (0.43 in) (Range value of 44 mm (1.73 in) from the tip of the jaw)
Dimensions and mass65 mm (2.56 in) W × 247 mm (9.72 in) H × 35 mm (1.38 in) D, 300 g (10.6 oz)
AccessoriesTEST LEAD L9207-10 ×1, CARRYING CASE C0203 ×1, LR03 Alkaline battery ×2, Instruction Manual ×1, Usage notes ×1

Log into your myHioki account to access more technical documents and information where available.

Seminar Videos On Demand

No results were found.

Seminar Schedule

No results were found.

Catalogs

Catalog: AC/DC CLAMP METER, AC CLAMP METER, CM4000 series Download PDF  [5MB] English

User Guides

No results were found.

Manuals

If you can not download, log into your myHioki account to access more technical documents and information where available.


No results were found.

Outline Drawings

If you can not download, log into your myHioki account to access more technical documents and information where available.


No results were found.

Technical Notes

No results were found.

Declaration of Conformity

No results were found.

Drivers, Firmware

No results were found.

Others

No results were found.

Options

Test leads

Options for the L9207-10 (L9207-10 is a bundled accessory)

TEST LEAD L9207-10

90 cm (2.95 ft) length

CONTACT PIN SET L4933

Attaches to the tip of the Test Lead L9207-10/DT4911, L9206, 60V DC/ 30V AC

SMALL ALLIGATOR CLIP SET L4934

Attaches to the tip of the L4932, L9207-10/DT4911, L9206, CAT III 300V, CAT II 600V

Options for Test leads

Options for the L4930, Test Pin Set L4932 is required when using the Small Alligator Clip Set L4934

CONNECTION CABLE SET L4930

1.2 m (3.94 ft) length

EXTENSION CABLE SET L4931

Expands the length of the cable with banana plug, 1.5 m (4.92 ft) length

TEST PIN SET L4932

Attaches to the tip of the banana plug cable, CAT IV 600V, CAT III 1000V

SMALL ALLIGATOR CLIP SET L4934

Attaches to the tip of the L4932, L9207-10/DT4911, L9206, CAT III 300V, CAT II 600V

ALLIGATOR CLIP SET L4935

Attaches to the tip of the banana plug cable, CAT IV 600V, CAT III 1000V

BUS BAR CLIP SET L4936

Attaches to the tip of the banana plug cable, CAT III 600V

MAGNETIC ADAPTER SET L4937

Attaches to the tip of the banana plug cable, CAT III 1000V

TEST PIN SET L4938

Attaches to the tip of the banana plug cable, CAT III 600V

BREAKER PIN SET L4939

Attaches to the tip of the banana plug cable, CAT III 600V

MAGNETIC ADAPTER 9804

Attaches to the tip of voltage cord, φ11 mm (0.43 in), compatible M6 pan screws

GRABBER CLIP 9243

Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V

Temperature measurement

THERMOCOUPLES(K) DT4910

K type, tip exposed, 0.3 mm (0.01 in) diameter, 80 cm (2.62 ft) length, -40 to 260 °C (-40 to 500 °F), tolerance ±2.5 °C

Other options

Bundled accessory

CARRYING CASE C0203

Applications