Logger Utility/Wireless Logger Collector for Models 8423,8430-20,LR8400-20,LR8400-23,LR8401-20,LR8402-20,LR8410-20,LR8431-20,LR8512,LR8513,LR8514,LR8515,LR8520,LR8400-92,LR8400-93,LR8450,LR8450-01,LR8101 and LR8102
V1.99 (Logger Utility)/V1.08 (Wireless Logger Collector) Jul 11, 2024
The copyright to the executable program file and associated documents is owned by HIOKI E.E. CORPORATION.
This utility may not be bundled with software or other publications which are sold for profit without the express written permission of the copyright owner.
Further, this product may not be modified without the express written permission of the copyright owner.
HIOKI disclaims any and all responsibility for any consequences arising out of use of this software.
Application software (LoggerUtility_V199_V108E.zip) |
---|
Overview
Logger Utility
Compatible Measuring Instrument
8423, 8430, LR8400, LR8400-03, LR8401, LR8402, LR8410, LR8410-90, LR8431, LR8432, LR8512, LR8513, LR8514, LR8515, LR8520, LR8400-92, LR8400-93, LR8450, LR8450-01, LR8101, LR8102
1 You can control instruments as well as perform data collection.
* The real-time data collection of the LR8450 and LR8450-01 is limited by the recording interval and the maximum number of channels that can be measured.
* The real-time data collection of measured values from the CAN unit for LR8450 and LR8450-01 is not possible.
* The real-time data collection of the LR8101 and LR8102 is limited by the maximum number of channels that can be measured.
* The real-time data collection of measured values from the Power Measurement Module for LR8101 and LR8102 can collect data only 30 arbitrary items.
2. You can also display and print the waveform of a measurement file as well as print. Waveform data can also be converted to CSV using this application.
* The waveform file containing the measured values of the CAN unit for LR8450 and LR8450-01 cannot be opened. Please use Gennect One.
* The waveform file containing the measured values of the Power Measurement Module for LR8101 and LR8102 cannot be opened. Please use GENNECT One.
3. Please refer to the Logger Utility PDF manual for additional features and instructions on how to use it..
Wireless Logger Collector
Compatible Measuring Instrument
LR8512, LR8513, LR8514, LR8515, LR8520
1. You can set up the measurement settings for the wireless logger.
2. Measurement data can be retrieved from the wireless logger.
3. Measurement data can be viewed (using the Logger Utility) and converted to a CSV file.
4. Please refer to the PDF manual of the wireless logger for additional features and instructions on how to use it.
How to install
1. Decompress the download file.
2. Application software installation: Execute Setup.exe.
USB driver installation
1. For Windows 7 or Windows 8 execute "DriverSetupWin7Win8.msi".
2. For Windows 10 or Windows 11 execute "DriverSetupWin10Win11.msi".
Version Upgrade History
Logger Utility : V1.99 Wireless Logger Collector V1.08
Logger Utility
1. Added support for Power Measurement Module for LR8101 and LR8102.
2. Minor problems were fixed or improved.
Logger Utility : V1.98 Wireless Logger Collector V1.08
Logger Utility
1. Compatibility to Model LR8101 and Model LR8102.
2. Minor problems were fixed or improved.
Logger Utility : V1.97 Wireless Logger Collector V1.08
Logger Utility
1. Compatibility to Model U8556 and Model LR8536 Current Module.
2. Minor problems were fixed or improved.
Logger Utility : V1.96 Wireless Logger Collector V1.08
Logger Utility
1. Synchronous operation function of LR8450 and LR8450-01 is now supported.
2. Confirmation message is shown when starting/stopping measurement, sending/receiving settings, or deleting settings.
3. Channel comments can be copied and pasted on the channel setting list display.
4. Minor problems were fixed or improved.
Wireless Logger Collector
1. Confirmation message is shown when executing self-diagnosis.
Logger Utility : V1.95 Wireless Logger Collector V1.07
Logger Utility
1. Repaired bugs:
Fixed a bug that the position of the event mark in text conversion and event list printing could be shifted.
2. The binary file that contains the data of the CAN unit for LR8450 and LR8450-01 can also be converted to text by batch conversion.
3. Minor problems were fixed or improved.
Logger Utility : V1.94 Wireless Logger Collector V1.07
Logger Utility
1. Revised instruction manual (added note about CAN unit for LR8450 and LR8450-01).
Logger Utility : V1.94 Wireless Logger Collector V1.07
Logger Utility
1. Repaired bugs:
Fixed a bug that the external program does not start at the event when an alarm occurs.
2. Repaired bugs:
Fixed a bug in the batch conversion function where the decimal point character in the system locale would be converted to the wrong values if it was set to something other than a period.
3. Added support for selecting the semicolon and system locale setting character as the separator when converting text.
4. Minor problems were fixed or improved.
Wireless Logger Collector
1. Repaired bugs:
Fixed a bug that incorrect scaling was set when the decimal point character in the system locale was set to something other than a period.
2. Minor problems were fixed or improved.
Logger Utility : V1.93 Wireless Logger Collector V1.06
Logger Utility
Compatible with the wireless unit for LR8450-01.
* The maximum analog channel that can collect real-time data is limited to 600 channels.
Minor problems were fixed or improved.
Logger Utility : V1.92 Wireless Logger Collector V1.06
Logger Utility
Supports real-time data collection of LR8450 and LR8450-01 with recording interval of 10ms to 50ms.
* Recording interval is limited to 10ms to 1h.
Logger Utility : V1.91 Wireless Logger Collector V1.06
Logger Utility
Added support for LR8450, LR8450-01 real-time data collection.
* Recording interval is limited to 100ms to 1h.
Logger Utility : V1.90 Wireless Logger Collector V1.06
Logger Utility
・Compatibility to Model LR8450 and Model LR8450-01 waveform files.
・Added a function to enlarge numerical values.
・Added a monitor function.
・Added support for Excel template files.
・Added support for saving numerical calculation results to a file.
・A/B cursor value can be copied to clipboard.
・When only one gauge is displayed, detailed numerical values are displayed.
Wireless Logger Collector
・Improved so that the combination order does not change when combining and exporting multiple data files.
Operating Environment
Windows 7 (32-bit or 64-bit) , Windows 8 (32-bit or 64-bit), Windows10(32-bit or 64-bit), Windows11(64-bit)