Home Products Search Results
Search
Keyword : "" 318 Result
Select
・Electrode for liquid samples
・Measure the resistivity of electrically guarded liquid samples ・Option for the SM7000 Series Super Megohmmeter
• Single range: 500 V/ 1000 MΩ • AC voltage testing
• Dedicated single-range meter with easy-to-read scale • LED backlight and battery indicator improve work efficiency
• PC software for use with HIOKI electrical safety testers • Inspect, record and save measurement data according to electrical safety standards controlling electrical safety measuring instruments • Test insulation, withstand voltage (hipot), protective continuity, and leakage current
• Pair with electrical safety testers to improve work efficiency and data management
・Shield box to aid in high insulation resistance measurement
・Prevent electromagnetic effects when measuring high resistance ・Option for the SM7000 Series Super Megohmmeters
• 2ch Analog + 4ch Logic • 1M-Sampling/s • Battery or AC-power
• Elevator maintenance, machine, motor and inverter fault analysis, testing and inspections • Record motor rush current • Measure CB timing • Analyze sequence controller issues
• 2ch logger, minimum 0.1 sec interval • Record pulse, rotation, and I/O signals • Transfer data wirelessly to mobile device or PC
• Perform pulse integration of vehicle speed or flow rate for equipment such as air conditioners • Applications in HVAC, automotive, co-generation, water, gas and petroleum industries
• Max. 54ch Analog to 112ch Logic • 20M-Sampling/s • 12-bit/16-bit A/D resolution
• Measure minute fluctuations in output from sensors in automobiles and other equipment • Identify voltage fluctuations in devices such as batteries at high levels of precision and resolution • Function generator, arbitrary waveform generator, and waveform measurement in a single device
• 600.0 mV to 1000 V DC/6.000 V to 1000 V AC • 6 A to 10 A DC and AC • Low-pass filter • 10 A direct input
• 6000 count general-purpose high-function DMM • For laboratory and research applications
• DC to 10MHz (−3dB), ±1.0% accuracy • Maximum 150 A rms • ±300 A peak (non-continuous)
• High S/N ratio • Directly connect to high impedance BNC input of oscilloscope or recorder • Ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers
• Constant DC V and DC A source • ±25 V, ±25 mA • Thermoelectric power generation, K, E, J, T, R,S, B, N thermocouple • Measure DC V and DC A
• DC voltage and current signal generator and tester for routine maintenance of standard devices • Perform maintenance or loop tests of instrumentation systems
• Non-metallic contact clip • For conductors with φ 2.4 to 17 mm core diameter • For use on 70 to 600 V lines (50/60 Hz)
• Safely and easily check phase direction with absolutely no metal contact with conductors
• For instrumentation • ±30mA DC current • 1 sec logging interval • 60000 data × 1ch memory
• Single-channel data logger for ±30mA DC instrumentation signals • Transfer data to PC while logging
• 6.8ms testing over 8ch simultaneously • Max. 1×10^15 Ω resistance testing • 1pA to 1mA current testing
• Test leak current on multi-layer ceramic capacitors (MLCC)
• DC to 50MHz (−3dB), ±1.0% accuracy • Maximum 30 A rms • ±50 A peak (non-continuous)
• Observe currents down to 10 mA • High S/N ratio • Ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers
• Direct-connection testing • Test SMDs with electrodes on the bottom • DC to 8MHz(Can be measured up to 10 MHz, when combined with the special order model IM3536-01) • Measurable sample sizes: Metric (Inch): 0402 (01005), 0603 (0201), 1005 (0402)
• High-precision 4-wire testing of advanced electronic components
• 4 channels for contact voltage signals • High-speed 100ns response
• Detect the presence of voltage or relay contact signals with Memory HiCorders at high speeds
• For up to 2 kV DC or 1 kV AC • Frequency bandwidth up to 10MHz
• Measure high voltage with Hioki Memory HiCorders • Analyze potential differences included in common mode voltages, such as IGBT • Inspect commercial power line waveforms, such as on 400V power lines
• 40Hz to 5kHz, ±0.3% accuracy • Rated 50 A AC, 10 mV/A output rate
• High accuracy AC current sensor with voltage output • Measure inverter devices or commercial power lines • Compact design fits in to narrow spaces
• 40Hz to 5kHz, ±0.3% accuracy • Rated 100 A AC, 1 mV/A output rate