POWER QUALITY ANALYZER PW3198
3-Phase 4-Wire Power Quality Analyzer Compliant to IEC61000-4-30 Class A Standards with Dynamic 1300V Range, Harmonic and Inter-harmonics Analysis Capabilities
Discontinued
Hioki portable power meters and analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy. The PW3198 is a power quality analyzer for monitoring and recording power supply anomalies, allowing their causes to be quickly investigated, and also for assessing power supply problems such as voltage drops, flicker, harmonics, and other electrical issues.
Product Video
Key Features
- Verify power problems in accordance with the IEC61000-4-30 Class A standard
- High accuracy and continuous gapless recording
(V: ±0.1% of nominal voltage, A and W: ±0.2% rdg. ±0.1% f.s.)
- CAT IV 600V - safe enough for incoming power lines
- Broadband voltage range lets you measure even high-order harmonic components of up to 80 kHz
- Wide dynamic range from low voltages up to 1300V (3P4W line-to-line voltage)
- Maximum 6000V transient overvoltage up to 700kHz
- LAN, USB and SD card interfaces
- Optional GPS BOX for synchronizing multiple devices
Model No. (Order Code)
PW3198 | Discontinued, Main unit, current sensor is sold separately |
---|---|
PW3198-90 | Discontinued, Kit includes software the 9624-50 |
Basic specifications
Measurement line type | Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra input channel (must be synchronized to reference channel during AC/DC measurement) | |||||
---|---|---|---|---|---|---|
Voltage ranges | Voltage measurement: 600.00 V rms Transient measurement 6.0000 kV peak |
|||||
Current ranges | 500.00 mA to 5.0000 kA AC (depends on current sensor in use) | |||||
Power ranges | 300.00 W to 3.0000 MW (determined automatically based on voltage and current range in use) | |||||
Basic accuracy | Voltage: ±0.1% of nominal voltage Current: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy Active power: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy |
|||||
Measurement items | 1. Transient over voltage : 2 MHz sampling 2. Frequency cycle : Calculated as one cycle, 40 to 70 Hz 3. Voltage (1/2) RMS: one cycle calculation refreshed every half cycle Current (1/2) RMS: half-cycle calculation 4. Voltage swell, Voltage dips, Voltage interruption 5. Inrush current 6. Voltage waveform comparison 7. Instantaneous flicker value: As per IEC61000-4-15 8. Frequency: Calculated as 10 or 12 cycles,40 to 70 Hz 9. 10-sec frequency: Calculated as the whole-cycle time during the specified 10 s period, 40 to 70 Hz 10. Voltage waveform peak, Current waveform peak 11. Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Reactive energy, Power factor, Displacement power factor, Voltage unbalance factor, Current unbalance factor (negative-phase, zero-phase) 12. High-order harmonic component (voltage/ current): 2 kHz to 80 kHz 13. Harmonic/ Harmonic phase angle (voltage/ current), Harmonic power: 0th to 50 th orders 14. Harmonic voltage-current phase angle: 1th to 50 th orders 15. Total harmonic distortion factor (voltage/ current) 16. Inter harmonic (voltage/ current): 0.5 th to 49.5 th order 17. K Factor (multiplication factor) 18. IEC Flicker, Δ V10 Flicker |
|||||
Record | 55 weeks (with repeated recording set to [1 Week], 55 iterations) 35 days (with repeated recording set to [OFF]) |
|||||
Interfaces | SD/SDHC memory card, RS-232C, LAN (HTTP server funtion), USB2.0 | |||||
Display | 6.5-inch TFT color LCD (640 × 480 dots) | |||||
Power supply | AC Adapter Z1002 (12 V DC, Rated power supply 100 V AC to 240 V AC, 50/60 Hz) Battery Pack Z1003 (Ni-MH 7.2 V DC 4500 mAh) |
|||||
Dimensions and mass | 300 mm (11.81 in) W × 211 mm (8.31 in) H × 68 mm (2.68 in) D (excluding protrusions), 2.6 kg (91.7 oz) (including battery pack) | |||||
Included accessories | Instruction manual ×1, Measurement guide ×1, Voltage cord L1000 ×1 set (Red/Yellow/Blue/Gray, each 1, Black ×4, Alligator clip ×8), Spiral tube ×20, Input Cable Labels ×1, AC adapter Z1002 ×1, Strap ×1, USB cable (1 m 3.28 ft length) ×1, Battery pack Z1003 ×1, SD memory card 2GB Z4001 ×1 |
Current input (8)
For power or load current measurement
(1 sensor necessary for single-phase measurements, and 2 or 3 sensors required for 3-phase measurements)
Connect with the 9695-02/ -03, Output BNC terminal, 3m (9.84ft) length
Leak current input (2)
Caution: Up to 5 A on Model PW3198
*Not capable of power measurement
Adapter (1)
AC/DC Current input (6)
*The AC/DC Auto-zero Current Sensor CT7731/CT7736/CT7742 cannot be used on its own with the PW3198. Be sure to use a set that includes the Display Unit CM7290, Output Cord L9095, and AC Adapter 9445-02 or 9445-03.
Connect to BNC terminal, 1.5 m (4.92 ft) length
For USA, 100 to 240 V AC, 9 V/ 1 A
Voltage input (6)
*The L1000 is bundled
Red/ Yellow/ Blue/ Gray each 1, Black 4, 3m (9.84ft) length, Alligator clip ×8
Attaches to the tip of the banana plug cable, Red/Black: 1 each, 185 mm (7.28 in.) length, CAT II 1000 V
When three-phase 3-wire connection, the voltage cord to be connected can be reduced from 6 to 3
When three-phase 4-wire connection, the voltage cord to be connected can be reduced from 6 to 4
Attaches to the tip of cord, red ×1, φ11 mm (0.43 in)
Attaches to the tip of cord, black ×1, φ11 mm (0.43 in)
Power supply (2)
*The Z1002, Z1003 are bundled
For main unit, 100 to 240 V AC
NiMH, Charges while installed in the main unit
Storage media (2)
*The Z4001 is bundled
SD Card Precaution
Use only the SD Card Z4001 sold by HIOKI. Compatibility and performance are not guaranteed for SD cards made by other manufacturers. You may be unable to read from or save data to such cards.
2 GB capacity
8 GB capacity
Cases (2)
Hard trunk type, Includes compartment for options
Bag type, Includes compartment for options
Other options (2)
To synchronize the PQ3198 / PW3198 clock to UTC
Straight Ethernet cable, supplied with straight-to-cross conversion adapter, 5 m (16.4 ft.)