INSULATION / WITHSTANDING HiTESTER 3159
0 to 0.2 kV/5 kV AC Insulation and Hipot Tester
Key Features
- Continuous testing of insulation (500 V/1000 V) and withstand voltage (500 VA transformer capacity)
- Insulation to withstand series test or withstand to insulation series test in auto mode, or individual test in manual mode
- Save up to 10 test settings each for the withstanding and insulation testing modes
- External I/O, RS-232C interface, Status output (relay contacts)
Basic Specifications
Accuracy guaranteed: 1 year
Monitor function | Output voltage, detected current, insulation resistance, Refresh rate: 2 times/s | |||||
---|---|---|---|---|---|---|
Power supply | 100 V AC, (50/60 Hz), 800 VA max. | |||||
Dimensions and mass | 320 mm (12.60 in) W × 155 mm (6.10 in) H × 330 mm (12.99 in) D, 21.5 kg (758.4 oz) |
|||||
Included accessories | H.V. Test Lead 9615 (high voltage side and return, 1 each) ×1, Power cord ×1, Instruction manual ×1, Spare fuse ×1 |
[Withstanding test]
Testing voltage | 0 to 2.5 kV / 0 to 5.0 kV AC, 2 range configuration 500 VA (30 minutes rated) | |||||
---|---|---|---|---|---|---|
Voltage setting | Manual setting | |||||
Waveform/Frequency | Same as the power supply waveform, synchronized with the power supply | |||||
Current measurement | 0.01 mA to 120 mA, True RMS rectified (digital display) | |||||
Voltage meter | Accuracy: ±1.5 % f.s. (digital), ±5 % f.s. (analog, f.s.=5 kV) | |||||
Current measurement | 0.01 mA to 120 mA, (Average value rectified, effective value digital display) | |||||
Measurement range | 2 mA/8 mA (0.01 mA resolution), 32 mA (0.1 mA resolution), 120 mA (1 mA resolution) | |||||
Voltage meter | Digital, Accuracy: ±1.5 % rdg. (f.s.=5.00 kV) | |||||
Judgment function | Window comparator method (Digital setting) |
[Insulation test]
Testing voltage | 500 V DC, 1000 V DC, Unloaded voltage: 1 to 1.2 times rated voltage | |||||
---|---|---|---|---|---|---|
Rated testing current | 1 to 1.2 mA, Shorted current: 4 to 5 mA (at 500 V), 2 to 3 mA (at 1000 V) | |||||
Measurement range/accuracy | 0.5 MΩ to 999 MΩ (at 500 V), and 1 MΩ to 999 MΩ (at 1000 V): ±4 % rdg., 1000 MΩ to 2000 MΩ: ±8 % rdg. |
|||||
Judgment function | Window comparator method (Digital setting) |
[Timer]
Setting range | 0.5 to 999 s | |
---|---|---|
-- | -- |
Input/Output cords (4)

REMOTE CONTROL BOX (SINGLE) 9613
For start/stop control, one-handed, 1.5 m (4.92 ft) cord length

REMOTE CONTROL BOX (DUAL) 9614
For start/stop control, double-handed, 1.5m (4.92 ft) cord length

H.V. TEST LEAD 9615
Red, Black each 1, 1.5 m (4.92 ft) length

RS-232C CABLE 9637
9 pin - 9 pin, cross, 1.8 m (5.91 ft) length