HIGH SPEED ANALOG UNIT U8976
High speed 200 MS/s, isolated input
Key Features
- High-speed sampling of 200 MS/s ensures catching high-speed phenomena
- Isolated 2 channel input
- Max. rated voltage to ground: 1000 V AC or DC (CAT II)
- High resolution measurement with 12 bit A/D
- For Memory HiCorder MR6000 only
Model No. (Order Code)
U8976 | For the MR6000 and similar products |
---|
Blazingly fast sampling that won't fail
The High Speed Analog Unit U8976 delivers a 30 MHz frequency band in addition to high-speed sampling at 200 MS/s. It has the performance needed to accurately capture switching waveforms during inverter testing, an application where high efficiency is critical. Adapted to the Memory HiCorder's direct input feature, it can accept inputs of up to 400 V DC.
Accurately measure inrush current with high-speed sampling
Combine the High-Speed Analog Unit U8976’s 30 MHz frequency band with the Current Probe CT6711 to measure inrush currents and minuscule currents.
Power can be supplied to current probes by using the Power Probe Unit Z5021 (MR6000 only).
List of Available Memory HiCorders
Please refer to the table here for the types of input units that can be used for each Memory HiCorder.
Basic specifications
Measurement functions | Number of channels: 2, for voltage measurement | |||||
---|---|---|---|---|---|---|
Input terminals | Isolated BNC terminal (Input impedance: 1 MΩ, Input capacitance: 22 pF) Max. rated voltage to earth: 1000 V AC or DC (with input isolated from the unit, the maximum voltage that can be applied between input channel and chassis and between input channels without damage) |
|||||
Measurement range | 100, 200, 400 mV f.s., 1, 2, 4, 10, 20, 40, 100, 200, 400 V f.s., 12 ranges (AC voltage for possible measurement/display using the memory function: 280 V rms) Low-pass filter: 5/500/5 k/1 MHz |
|||||
Measurement resolution | 1/1600 of measurement range (using 12-bit A/D conversion) | |||||
Highest sampling rate | 200 MS/s (2 channel simultaneous sampling) | |||||
Measurement accuracy | ±0.5% f.s. (with filter 5 Hz, zero position accuracy included) | |||||
Frequency characteristics | DC to 30 MHz -3 dB, with AC coupling: 7 Hz to 30 MHz -3dB | |||||
Input coupling | AC/DC/GND | |||||
Max. allowable input | 400 V DC (when direct input), 1000 V DC (when using the 9665) | |||||
Dimensions and mass | 106 mm (4.17 in) W × 19.8 mm (0.78 in) H × 196.5 mm (7.74 in) D, 280 g (9.9 oz) | |||||
Included accessories | None |
Use with these Products (1)
* Main products are listed below. For more information, please see each product page.
Voltage measurement Type A (4)
* Input voltage is limited to the specifications of the input modules in use
* Max. rated voltage to earth is limited to the specifications of the input modules in use
• Flexible φ 4.1 mm (0.16 in) thin dia.
• Cable allowing for up to 600 V input
• 1.8 m (5.91 ft) length
Red/black set attaches to the ends of the Connection Cord L9790
Red/black set attaches to the ends of the Connection Cord L9790
Red/black set attaches to the ends of the Connection Cord L9790
Voltage measurement Type B (1)
* Input voltage is limited to the specifications of the input modules in use
* Max. rated voltage to earth is limited to the specifications of the input modules in use
•φ 5.0 mm (0.20 in) dia.
•Cable allows for up to 300 V input
•1.7 m (5.58 ft) length
•Small alligator clip
Voltage measurement Type C (2)
* Input voltage is limited to the specifications of the input modules in use
* Max. rated voltage to earth is limited to the specifications of the input modules in use
•φ 5.0 mm (0.20 in) dia
•Cable allows for up to 600 V input
•1.8 m (5.91 ft) length
•Includes detachable large alligator clips
Attaches to the tip of the banana plug cable, Red/Black: 1 each, 185 mm (7.28 in.) length, CAT II 1000 V
Voltage measurement Type D (2)
* Max. rated voltage to earth is limited to the specifications of the input modules in use
* For a list of compatible Memory HiCorders, please see the product catalog