AC/DC CURRENT SENSOR 9709-05

High Precision DC to 100 kHz/500 A AC/DC Pull-through Current Sensor with ±0.05% Basic Accuracy

Discontinued

Conversion cable is required depending on the compatible product.

Hioki pull-through AC/DC current sensors are best-in-class devices for use with power meters, Memory HiCorders and high performance oscilloscopes. The 9709 is a DC to 100 kHz/500 A sensor, ideal for capturing current signals from switching power supplies, inverters, power conditioners, etc.

CAT III 1000 V

Key Features

  • Super high precision, ±0.05% amplitude accuracy, ±0.2° phase accuracy
  • DC to 100 kHz bandwidths with excellent frequency characteristics
  • Ideal for evaluation of solar power generation and fuel cells to measure battery charge and discharge and the secondary side of inverters
  • For observing waveforms to be used with the oscilloscopes or Memory HiCorders (use with SENSOR UNIT)

Model No. (Order Code)

9709 Discontinued, 500 A AC/DC, PL23 terminal
9709-05 Discontinued, 500 A AC/DC, ME15W terminal

Basic specifications

Accuracy guaranteed: 6 months
Rated input current 500 A AC/DC
Max. allowable input 700 Arms (1000 Apeak, requires derating at frequency)
Frequency characteristics Amplitude: DC to 100 kHz
Phase: DC to 100 kHz
Amplitude and Phase accuracy DC, 45 Hz ≤ f ≤ 66 Hz
(±0.05 % rdg. ±0.01 % f.s. (Phase: ±0.2°) )Defined to 100 kHz
Output voltage rate 2 V /rated current value
(voltage output with the Sensor Unit, use with a device having a 1 MΩ input resistance or higher)
Max. rated voltage to earth AC/DC 1000 V (50/60 Hz, CAT III )
Core diameter φ 36 mm (1.42 in)
Operating temperature, humidity 0°C to +50°C (32°F to 122°F)
80% rh or less (with no condensation)
Power supply ±11 V to ±15 V DC (Power suppled via the Sensor Unit, which supports 100 to 240 V AC)
Power consumption 5 VA max. (at 500 A/55 Hz, ±12 V power requirement)
Dimensions and mass 160 mm (6.30 in)W × 112 mm (4.41 in)H × 50 mm (1.97 in)D, 850 g (30.0 oz), cord length: 3 m (9.84 ft)
Included accessories Instruction manual ×1, Mark bands ×6

Compatible models: 9709, 9709-05

Compatible models 9709 9709-05
Power Analyzer
PW6001, PW3390
△ (Requires CT9900) OK
Power Analyzer
3390
OK △ (Requires CT9901)
Power HiTester
3193 series
OK △ (Requires CT9901)
Current Unit
8971
△ (Requires the 9318) △ (Requires the 9318, CT9901)
F/V Unit
8940
△ (Requires the 9318, the 9705) △ (Requires the 9318, the 9705, CT9901)

Options A (5)

Options B (1)

The CT9903 connects up to 2 cables in series, Cannot be used in combination with the 9277 to 9279

Options C (2)

The CT9902 connects up to 2 cables in series

Options D (1)

For connecting to the F/V Unit 8940 or Current Unit 8971


Related Products