Evaluation of the Efficiency of Solar Inverters That Support High-Voltage Input
Issues
Energy losses can be reduced by transmitting power at high voltages. To boost the efficiency of power generation systems, the use of solar inverters that support high-voltage input is on the rise. It is necessary to measure high voltages to measure the efficiency of those devices.
Solutions
The VT1005 can be used with a power analyzer PW8001 to measure the efficiency of inverters that use SiC power devices.
High-Voltage Measurements
The VT1005 allows power analyzers to measure voltages of up to 5000 V.
Measurement Category
- 5000 V rms (±7100 Vpeak) No measurement category
- 2000 V rms CAT II
- 1500 V rms CAT III
Measurement of High-Frequency Components
The VT1005’s measurement band is DC to 4 MHz, allowing it to measure voltage from DC to high frequencies.In addition, the excellent flatness of the amplitude and phase characteristics in the measurement band enables highly accurate power measurement.