SD card sold in commercial stores
https://www.hioki.com/sg-en/support/faq/detail/id_210
Why are the SD cards sold in commercial stores not recommended for use with HIOKI products?
-
Cannot open the data from clamp-on power meter on the SF1001.
https://www.hioki.com/sg-en/support/faq/detail/id_208
The SF1001 software cannot open the data measured by the clamp-on power meter after opening it on a PC.
-
Record for a long time using Power Quality Analyzer PQ3198/PW3198 (Repeat function)
https://www.hioki.com/sg-en/support/faq/detail/id_207
I want to record for long time using my power quality anlyzer. Is the repeat function effective?
-
How is voltage measured using non-metallic contact?
https://www.hioki.com/sg-en/support/faq/detail/id_206
I heard that you have a power meter that can measure voltage without making contact to metallic terminals.
What is the measurement principle?
-
Negative power displayed on a Clamp-on Power Logger
https://www.hioki.com/sg-en/support/faq/detail/id_205
I measured the power trend using a Clamp-on Power Logger, but the power value is negative. Why does this happen?
-
Wiring check on Clamp-on Power Meters
https://www.hioki.com/sg-en/support/faq/detail/id_204
The wiring check of the Clamp-on Power HiTESTER 3169 does not give "OK", though the wiring is correct. Is it OK to measure under this condition?
-
Convert the 3196's text mode data to binary data
https://www.hioki.com/sg-en/support/faq/detail/id_203
I measured power quality in text mode of the 3196 by mistake. Is there any way to convert the data to binary data to analyze on the PQA HiVEW Pro 9624-50?
-
How to read "Status" data of the 3197
https://www.hioki.com/sg-en/support/faq/detail/id_202
How do I read the Status data in the 3197's TIME PLOT data (97intvl.csv)?
-
The 3197 Application displays "Cannot open the file."
https://www.hioki.com/sg-en/support/faq/detail/id_201
The 3197 Application displays the message "Cannot open the file."
-
3196 and 9624-50 Compatibility
https://www.hioki.com/sg-en/support/faq/detail/id_197
Is the 9624-50 PQA HiView Pro compatible with the discontinued 3196 Power Quality Analyzer?
-
PW3198 and 9624-10 Compatibility
https://www.hioki.com/sg-en/support/faq/detail/id_196
Is the discontinued 9624-10 PQA HiView Pro software compatible with PW3198 Power Quality Analyzer?
-
What communications commands are available when using the DT4900-01 to communicate with a computer?
https://www.hioki.com/sg-en/support/faq/detail/id_195
What communications commands are available when using the DT4900-01 to communicate with a computer?
-
Can the two units that are included with the LR8400 be removed?
https://www.hioki.com/sg-en/support/faq/detail/id_193
Can the two units that are included with the LR8400 be removed?
-
Is it possible to measure the leakage current of a 3-phase/3-wire or 3-phase/4-wire device?
https://www.hioki.com/sg-en/support/faq/detail/id_191
Is it possible to measure the leakage current of a 3-phase/3-wire or 3-phase/4-wire device?
-
I’m seeing voltage measured values that are lower than the nominal voltage.
https://www.hioki.com/sg-en/support/faq/detail/id_190
I’m seeing voltage measured values that are lower than the nominal voltage.
-
Is the following connection method correct: OUTPUT terminal + coaxial cable + 50 Ω terminating resistor + measuring instrument?
https://www.hioki.com/sg-en/support/faq/detail/id_189
Is the following connection method correct: OUTPUT terminal + coaxial cable + 50 Ω terminating resistor + measuring instrument?
-
Can I change the full-scale value by changing the CT ratio? Will the accuracy and resolution change as a result?
https://www.hioki.com/sg-en/support/faq/detail/id_188
Can I change the full-scale value by changing the CT ratio? Will the accuracy and resolution change as a result?
-
What is the smallest current value that can be measured with wideband current probes?
https://www.hioki.com/sg-en/support/faq/detail/id_186
What is the smallest current value that can be measured with Hioki wideband current probes?
-
What is two-point (two-pole) method of Earth Tester?
https://www.hioki.com/sg-en/support/faq/detail/id_n1021221
What is the 2-point (2-pole) measurement method of Earth Tester FT6031-50?
-
Is it possible to measure power in multiple circuits using the same voltage circuit?
https://www.hioki.com/sg-en/support/faq/detail/id_185
Is it possible to measure power in multiple circuits using the same voltage circuit?