AC/DC CLAMP METER CM4375-50

True RMS 1000 A AC/DC Clamp Meter
Easily Get Into Tight Spaces - Innovative Jaw Provides Remarkable Accessibility

CM4375-50 Product Introduction | 1000 A AC/DC Clamp Meter

Hioki clamp on meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. The CM4375-50 is a 1000 A AC/DC True RMS clamp meter that features a uniquely designed slim jaw that lets you easily get into the narrow gaps between cables in crowded electrical distribution boxes without fear of damaging the cables or the clamp meter. The broad IP54 dustproof and waterproof enclosure to enable professionals to work quickly in challenging situations including the development, repair, and maintenance of equipment and devices such as electric vehicles. Additionally, the high-voltage DC measurement capability of up to 2000 V (*1) is ideal for the clamp maintenance inspections of electrical and solar power equipment.

Key Features

  • CAT IV 600 V, CAT III 1000 V
    When using P2000: CAT III 2000 V, CAT IV 1000 V
  • Easily get into tight spaces between cables thanks to thin sensor structure
  • Measure DC voltages of up to 2000 V (*1) for open voltage inspections of solar panels
  • Automatic AC/DC function helps boost work efficiency, Measure up to 1000 A
  • Simultaneously measure inrush current in RMS and crest values
  • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (*2)
  • Harmonic analysis from 1st to 30th order with GENNECT Cross (*2)
  • *1:When using the optional DC High Voltage Probe P2000. The clamp meter itself is capable of measuring up to 1000 V DC.
  • *2:Wireless Adapter Z3210 is necessary.

Model No. (Order Code)

CM4375-50 Wireless Adapter Z3210 not included
CM4375-91 DC High Voltage Probe P2000 Kit

Data can be downloaded to tablets and smartphones using Hioki’s dedicated free app "GENNECT Cross," available from the Google Play or App Store.

Safe inspection of solar installations with high voltage

DC High V Probe Mode

- Enables high voltage measurement up to CAT III 2000 V
- Safely measure solar installations like the mega-solar without interrupting the grid by simply connecting the DC High Voltage Probe P2000 to compatible Hioki clamp meters and digital multimeters (DMMs)

See details about DC High Voltage Probe P2000

Wireless communication capability for even greater convenience

Wireless support

When the Wireless Adapter Z3210 is installed, Bluetooth® wireless communication is enabled. It transfers measurements to your smartphone or tablet and allows you to quickly create reports with field photos and drawings.

See details about Wireless Adapter Z3210

Excel® Direct Input Function (*1)

Boost work efficiency in the field by letting you directly transfer measurement data to (i.e., enter measured values directly into) templates created as Excel®.

  • *1:The optional Wireless Adapter Z3210 is required.

Helping personnel analyze issues in the field

Harmonic measurement

When combined with GENNECT Cross (*2), you can perform simple harmonic analysis. Applications include problem analysis of power supply systems.

See here for details about GENNECT Cross

Problems that can be caused by harmonics

  • Equipment burn-out and destruction due to overheating
  • Malfunctions of power control devices
  • Increased loss along with reduced service life and efficiency for power devices
  • *2:GENNECT Cross is an free app that lets you connect field measuring instruments to smartphones and tablets using Bluetooth® communications. Wireless Adapter Z3210 (sold separately) is required in order to pair the instrument with GENNECT Cross.

Uncompromising Design

Innovative jaw provides remarkable accessibility

Panel overcrowding is commonly found in many power distribution breakers and termination boxes. The newly designed thin sensor gets into even the most limited spaces. Eliminate the issues of trying to find the right wire or forcing the clamp around thick cables.

Damage-resistant jaws! Guaranteed for 30,000 open-close cycles

The new and improved design features stronger jaws (the current sensor portion of the instrument) and a dramatic boost in the duration of the warranty from 10,000 to 30,000 open-close cycles to ensure the instrument will provide even more years of reliable use. The CM4375siries deliver the dual functionality of ease of clamping and resistance to damage.

More recommended features

Inrush (Rush current): Assess transient currents at motor startup

Can simultaneously measure inrush current in RMS as well as maximum crest values at motor startup and for welding currents.

The clamp meters automatically detect the duration of the inrush current (which can range from several dozen milliseconds to several hundred milliseconds) and measure the current during that interval, enabling them to yield more accurate measurements than standard clamp-on meters whose measurement interval is fixed to 100 ms.

Use the inrush current feature for motor installation and maintenance to prevent circuit breakers from tripping, especially with high efficiency motors that have inrush current many times greater than the steady-state current of the motor.

Stop worrying about losing test lead caps

Test Lead L9300 incorporate integrated caps for greater convenience and safety. The design lets you change the measurement category simply by sliding the test lead’s protective finger guard. You no longer have to worry about losing caps!

3D View

Basic specifications

Accuracy guaranteed: 1 year
DC Current range 1000 A, (Max. display 999.9 A) , Basic accuracy: ±1.3% rdg. ±0.3 A (at 30.1 A - 999.9 A)
AC Current range 1000 A (Max. display 999.9 A, 10 Hz to 1 kHz, True RMS), Basic accuracy 45-66 Hz: ±1.8% rdg. ±0.3 A (at 30.1 A - 900.0 A)
Crest factor 1000 A range: 1.5
DC+AC Current range 1000 A (DC, 10 Hz to 1 kHz, True RMS), Basic accuracy DC, 45-66 Hz: ±1.3% rdg. ±1.3 A (at 30.1 A - 900.0 A)
DC Power range 0.000 kVA to 1000 kVA (When using P2000: 0 kVA to 2000 kVA) (Automatically switched based on voltage range), Basic accuracy: ±2.0% rdg. ±20 dgt.
DC Voltage range 600.0 mV to 1000 V (When using P2000: 600.0 V to 2000 V)
AC Voltage range 6.000 V to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy 45 - 66 Hz: ±0.9% rdg. ±0.003 V (at 6 V)
DC+AC Voltage range 6.000 V to 1000 V, 4 ranges, Basic accuracy DC, 45-66 Hz: ±1.0% rdg. ±0.013 V (at 6 V)
Resistance range 600.0 Ω to 6.000 MΩ, 5 ranges, Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)
Electrostatic capacity range 1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)
Frequency range 9.999 Hz to 999.9 Hz, 3 ranges, Basic accuracy: ±0.1% rdg. ±0.003 Hz (at 9.999 Hz)
Temperature (K) -40.0°C to 400.0°C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0°C
Harmonic levels [With Z3210 installed] Voltage/Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
*Harmonics can be displayed with our free app GENNECT Cross.
Other functions Continuity check, Diode check, Automatic AC/ DC detection, DC current and DC voltage polarity detection function, MAX/MIN/AVG/ PEAK MAX/PEAK MIN value display, Low-pass filter function, Display value hold, Auto hold, Backlight, Auto power save, Buzzer sound, Zero-adjustment
Dustproof, waterproof IP20 (Voltage measurement in a completely dry condition. When jaw closes)
IP54 (While in storage)
Power supply LR03 Alkaline battery ×2
Continuous use: approx. 40 hr (without Z3210 installed), approx. 20 hr. (with Z3210 installed and using wireless communications)
Other conditions: 100 A AC measurement, backlight off, 23°C reference value
Core jaw diameter φ34 mm (1.34 in)
Smallest dimension of jaw cross-section 9.5 mm (0.37 in) (Range value of 44 mm (1.73 in) from the tip of the jaw)
Dimensions and mass 65 mm (2.56 in) W × 242 mm (9.53 in) H × 35 mm (1.38 in) D mm, 350 g (12.3 oz)
Included accessories Test Lead L9300, Carrying Case C0203, LR03 Alkaline battery ×2, Instruction Manual ×2, Operating Precautions ×1

Test leads (3)

L9300 is a bundled accessory

Options for Test leads (for the L9207-10, L9300) (2)

Attach L9207-10 with the cap removed.
Slide the guard of L9300 and attach as measurement category II.

Options for Test leads (for the L4930) (11)

Test Pin Set L4932 is required when using the Small Alligator Clip Set L4934

Temperature measurement (1)

Carrying case (2)

C0203 is an included accessory


Related Products