Features
・Multi-instrument data integration in a unified workspace
・Up to 30 measuring instruments can be connected to a single PC via LAN.
・Number of channels: Up to 3,000 channels
・Time-synchronized measurement, video, and GPS data
・High-speed data acquisition with 1 ms sampling resolution
Supported measurement instruments
LR8101, LR8102, LR8450, PW4001, PW8001
Sample data
This sample data is designed to let you experience the features and operability of GENNECT Space SF4300.
・Post-downloaded steps
Step 1: Extract the ZIP File
Right-click on the ZIP file.
Select [Extract All...] from the menu.
After selecting the destination, click the [Extract] button.
Step 2: Import the sample data
Launch GENNECT Space, and then go to [File] - [Import] on the menu bar to load the sample data.
・Dataset overview
Sample data 1: EV real-world driving test (measured data, camera, and map)
Sample data 2: Motor durability test (measured data, camera, and thermal camera)
Sample data 3: Simultaneous power and temperature measurement via data logger (measured data only)
Version upgrade history
V1.50 (Aug, 2026)
- Fixed an issue that rarely caused the application to freeze when navigating to the Channel Selection screen in the Logging Settings screen.
- Added support for importing instrument data files.
Supported instruments: LR8101, LR8102, LR8450, PW4001, PW8001, MR6000
- Added support for exporting data in MDF file format.
- Added Level Bar, Analog Meter, Stats, and Event panels.
- Expanded the power recording interval settings for Power Analyzers.
- Added other new features and various improvements.
V1.02 (Mar. 2026)
Fixed an issue where closing the settings screen while configuring the measuring device in the app could cause a discrepancy between the scaling values in the app and the device. If logging measurement was started in that state, incorrect measurement values could be displayed or output.
Fixed an issue where, after changing the measurement unit in the app’s device settings, the updated unit might not be reflected when navigating to the channel settings screen.
Fixed an issue where the firmware for LR8450 and LR8450-01 could not be updated to the latest version (V3.00) from the app.
V1.01 (Mar. 2026)
First release
Operating Environment
・OS: Windows 11, Windows 10 (64 bit, 21H2 or later)
・Processor: Intel Core i7 10th generation (or equivarent) or better
・Memory: 32 GB or more
・Storage: SSD