• AC, 1kHz testing source • Max 22 VDC, 0.1 mV resolution, ±0.01% accuracy • 300mΩ to 3Ω range
• High-speed internal resistance and battery voltage testing on high volume production lines of small secondary batteries used in mobile devices • Inspection during mass production of compact cells • Quick 3 ms response time
• DC, max 1A testing source • 2.2ms measurement speed • 10 mΩ to 1000 MΩ range, 0.01 μΩ resolution • Multiplexer option: 4-wire testing across 20 points
• R&D of advanced components including motors, transformers, power relays, switches, and connectors • Low-power resistance testing with max. 20mV open voltage
• 40Hz to 5kHz, ±1.0% accuracy • Rated 1000 A AC, 0.5 mV/A output rate
• High accuracy AC current sensor with voltage output • For inverter devices or commercial power lines
• |Z|, L, C, R testing • 1MHz to 1.3GHz • 0.5ms test speed, ±0.65% accuracy, 0.07% variability • Measure LCR and conduct frequency sweeps simultaneously
• For R&D and high volume production of ferrite chip beads and chip inductors • Comparator and Contact Check
• DC, max 100mA testing source • 0.9 ms fastest measurement speed • 100 mΩ to 1000 Ω range, 0.1 μΩ resolution
• Designed for automated lines • Inspect chip resistors and EMI components prior to shipping for quality control • Comparator, start delay, OVC, fault detection and many other automation functions
• 40Hz to 5kHz, ±0.3% accuracy • Rated 5 A AC, 10 mV/A output rate
• High accuracy AC current sensor with voltage output • For inverter devices or commercial power lines • For measuring the secondary side of 5A CTs
• 15ch logging module • Pair with Hioki LR8410 Wireless Logging Station
• Record voltage and temperature • Connect up to 7 units wirelessly for a maximum of 105 channels • 2-terminal M-3 mm screw connection
• 600.0 mV to 600.0 V DC/6.000 V to 600.0 V AC • Low-pass filter • No current or resistance measurements • Voltage detector
• 6000 count pocket DMM for general electrical work • Designed with no current measurements for dedicated voltage testing
• For the Memory HiCorder • Convert data, print and display waveforms
• Display waveform screens, X-Y graphs, and numerical results • Comprehensive search function
• 4 channels for contact voltage signals • 500ns response • Miniature terminal type
• Detect the presence of voltage or relay contact signals with Memory HiCorders
• 600.0 mV to 600.0 V DC/6.000 V to 600.0 V AC • Low-pass filter • Capacitance and diode testing
• 6000 count pocket-sized general-purpose DMM for laboratories and R&D applications • Designed with no current functions for dedicated voltage testing
• 419.9 mV to 500 V DC / 4.199 V to 500 V AC • Average rectified • Card-sized
• 4199 count card-style pocket DMM for general electrical maintenance and testing • Test leads wrap neatly in back
• 2 channels for CT6710 series or 4 channels for CT6700 and 3270 series • ±12 V output
• Power supply for wideband current probes for output to Memory HiCorders or oscilloscopes
• Testing of general-use electrical devices • Built-in support for networks other than medical-use electrical devices • Supports equipment with up to 20A rated current
• Leakage current tester for non-medical use equipment • Complies with Electrical Appliances and Materials Safety Act, JIS/IEC/UL standards
・Electrode for chip capacitor
・Measure the resistivity of the tips of capacitors effectively ・Option for the SM7000 Series Super Megohmmeter
• Max. 16ch Analog + 8ch Logic • 60ch scanner • 500k-Sampling/s
• Measure acceleration fluctuation in automobiles, transportation equipment and industrial robots • Performance and durability testing • Inverter and motor testing
• 10 Hz to 20 kHz, ±2% accuracy • Rated 5000 A/ 500 A AC
• Rogowski type AC sensors in 3 different loop diameter sizes from 100 to 254 mm • Battery or AC Adapter-powered to pair with any power meter or DAQ • Thin coil easy to use in confined spaces and with complicated wiring
• 1 GB capacity • PC card adapter bundled
Removable Compact Flash Cards for Storing Important Data and Transferring Measured Values to a PC