WIRELESS CLAMP LOGGER LR8513
Measure Load Current and Leak Current Easily with Clamp Sensors
Hioki Memory HiLoggers are high-speed data loggers for recording multiple channels of voltage, temperature, resistance or humidity signals, some models providing complete isolation between channels and strong noise resistance. The Hioki LR8513 is a wireless, 2-channel AC/DC current input module that utilizes Bluetooth® technology to either send measured data to the Hioki LR8410 Wireless Logging Station or to an Android (TM) tablet.
Key Features
- Measure AC and DC load current and AC leak current
- Choose from many current sensors
- Place inside a distribution panel, close the cover, and monitor measured values from the outside
- Measure power easily—just set the voltage and power factor
- Compact, two-channel model fits where other devices don’t
- Download measurement data to a tablet or computer with Bluetooth® wireless technology or capture in real time with the LR8410
- Three-way power (AC adapter, AA alkaline batteries, or external 5 to 13.5 V power supply)
- Store 500,000 data points per channel
Model No. (Order Code)
LR8513 | 2 ch, sensor is sold separately |
---|
Precautions concerning use of the CT7731, CT7736, and CT7742 to measure AC/DC load current
The AC/DC Auto-zero Current Sensor CT7731/CT7736/CT7742 cannot be connected directly to the Wireless Clamp Logger LR8513.
The Display Unit CM7290 and Output Cord L9095 is required to connect those sensors to the LR8513.
Precautions concerning use of the CT7044, CT7045, and CT7046 to measure AC/DC load current
The AC Flexible Current Sensor CT7044/CT7045/CT7046 cannot be connected directly to the Wireless Clamp Logger LR8513.
The Display Unit CM7290 and Output Cord L9095 is required to connect those sensors to the LR8513.
QR Code link to Hioki’s Android app*
Scan this QR Code* with an Android device to access the Google Play download page directly
*Registered trademark of Denso Wave Incorporated.
A compact 2-channel clamp logger that’s ideal for simple measurements such as AC/DC load current or AC leakage current
For applications such as
- Assessing demand every 30 minutes (average value recording)
- Assessing peak leakage current (Maximum value recording)
- PV maintenance
- Automobile tests
- Forklifts
- Railroads
- Equipment maintenance
- Simple electrical measurement (set the voltage and power factor)
A wireless logger whose data can be captured by a smartphone or PC
Built-in Bluetooth(R) wireless technology.
Use your tablet or PC to collect data even as signals are being logged.
No matter what time during measurement you collect the data, data is automatically merged together into one single file.
Review data trends by observing waveforms and numerical values right there in the field.
*Pictured: LR8514
Real-time monitoring
By using the Hioki LR8410-20 to acquire data, you can view the waveforms in real time.
Furthermore, previous waveforms can be viewed while the device is taking measurements.
*Pictured: LR8514
A compact wireless logger that you can place anywhere
Pocket size for installation anywhere.
Use the optional MAGNETIC STRAP to hang it on a wall – solving all of your installation space problems.
Installing a data logger in a switchboard or control panel has never been easier.
Gone is the need to feed wiring through the panel-data collection is done wirelessly so you can close the panel door for safe measurements.
The loggers are also useful for measuring in difficult-to-wire locations, like high places or on moving machines.
Power with AA batteries or an AC adapter
The logger will operate for about 10 days on two AA-size alkaline batteries.
(Recording interval: 1 sec, with Bluetooth(R) ON)
Since the batteries will last longer the less time the Bluetooth(R) function is operating, the instrument features a power-saving function that automatically turns on the Bluetooth(R) circuit during predefined time periods.
While communications are disabled, data is reliably stored in the instrument’s large built-in memory, which can hold 500,000 data points per channel.
Use the AC adapter to record data over extended periods of time with peace of mind.
Basic specifications
Functionality | [Used as standalone product (Data collected manually) ] Windows PC or Windows tablet (CD-R with software included) Android smartphone or Android tablet terminal (Software can be downloaded free of charge from Google Play.) *Communication range varies with the performance of the computer or tablet (up to a line-of-sight distance of roughly 30 m) [Used as logging module (Real-time measurement) ] Device can be used as an LR8410 logging module to record and display data in real time and to control up to 7 units, Communication distance: 30 m |
|||||
---|---|---|---|---|---|---|
Number of channels | 2ch (common GND) | |||||
Measurement items | AC load current, DC load current, AC leak current (using current sensor) | |||||
Effective value calculation | Software calculates the true RMS value | |||||
Measurement range | 500.0 mA to 2000 A AC, 10.00 A to 2000 A DC (By current sensor) *Current and leak current that occur intermittently cannot be measured. |
|||||
Measurement accuracy | ±0.5% rdg.±5 dgt. (DC, AC 50/60 Hz) *Add the sensor’s accuracy when the current sensor is connected | |||||
Display items | Measurement value, date, time, number of recorded data, maximum value, minimum value, and average value | |||||
Functions | Alarm, Scaling, Recording operation hold function, Erroneous operation prevention, Comment recording function, Power saving function, Authentication function, Free run | |||||
Recording | [Capacity] 500,000 data items for each channel [Mode] Instantaneous value, average value, maximum value [Interval] 0.5 to 30 sec, 1 to 60 min, 14 selections | |||||
Power source | AC Adapter Z2003 (100 to 240 V AC, 50/60 Hz), AA alkaline batteries (LR6) ×2, External power 5 to 13.5 V DC (can also be supplied from USB bus power, with a conversion cable) | |||||
Continuous operating time ([Capacity] 500,000 data items for each channel) (23˚C) | 3 months (Recording interval of 1 min, Bluetooth® OFF), 10 days (Recording interval of 1 sec, Bluetooth® ON), 5 days (Recording interval of 0.5 sec, during real-time measurement with the LR8410) | |||||
Dimensions and mass | 85 mm (3.35 in) W × 75 mm (2.95 in) H × 38 mm (1.50 in) D, 130 g (4.6 oz) (excluding the battery) | |||||
Included accessories | CD-R ×1 (Instruction Manual, Logger Utility, Wireless Logger Collector), Measurement Guide ×1, Caution for Using Radio Waves × 1, AA alkaline batteries (LR6) ×2 |
Countries and regions where wireless operation is currently supported (LR8513)
Countries and regions where wireless operation is currently supported | Australia, Austria, Bangladesh, Belgium, Bulgaria, Canada, Chile, Colombia, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Georgia, Germany, Greece, Hong Kong, Hungary, Iceland, Indonesia, Ireland, Israel, Italy, Japan, Kenya, Latvia, Liechtenstein, Lithuania, Luxembourg, Macao, Malta, Myanmar, Netherlands, New Caledonia, New Zealand, Norway, Poland, Portugal, Romania, Saudi Arabia, Singapore, Slovakia, Slovenia, Spain, Sweden, Switzerland, Taiwan, Thailand, Turkey, United Kingdom, United States, Viet Nam | |||||
---|---|---|---|---|---|---|
Note | Use of devices that emit radio radiation requires approval in the country of use. Thus, use of the instrument in a country or region where they have not been approved may be subject to penalty as a violation of law. |
AC load current sensors (2)
Specifications listed are for the sensor itself alone. When combined with the Wireless Clamp Logger LR8513, the measurement range conforms to the specification of the LR8513. For details, please refer to the instruction manual.
• 40 Hz to 1 kHz bandwidth
• Primary: 500 A AC
• Secondary: 1mV AC/A
• Max. input of 600 A AC
• φ46 mm (1.81 in) dia.
AC load current sensors (2)
Specifications listed are for the sensor itself alone. When combined with the Wireless Clamp Logger LR8513, the measurement range conforms to the specification of the LR8513. For details, please refer to the instruction manual.
Connect with the 9695-02/ -03, Output BNC terminal, 3m (9.84ft) length
AC leak current sensors (2)
Specifications listed are for the sensor itself alone. When combined with the Wireless Clamp Logger LR8513, the measurement range conforms to the specification of the LR8513. For details, please refer to the instruction manual.
AC load current sensors (3)
- Specifications listed are for the sensor itself alone. When combined with the Wireless Clamp Logger LR8513, the measurement range conforms to the specification of the LR8513. For details, please refer to the instruction manual.
- The Display Unit CM7290 and the Output Cord L9095 (available separately) are required in order to use these current sensors.
Connect to BNC terminal, 1.5 m (4.92 ft) length
AC/DC load current sensors (5)
- Specifications listed are for the sensor itself alone. When combined with the Wireless Clamp Logger LR8513, the measurement range conforms to the specification of the LR8513. For details, please refer to the instruction manual.
- The Display Unit CM7290 and the Output Cord L9095 (available separately) are required in order to use these current sensors.
Connect to BNC terminal, 1.5 m (4.92 ft) length
Power supply or other (2)
100 V to 240 VAC
Extra strength