AC/DC CURRENT BOX PW9100
Direct Current Measurement Element that Delivers a Wide Bandwidth and Superior Accuracy
To Be Discontinued
Hioki benchtop power meters and power analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy. The PW9100 is a direct AC/DC current measurement option for the PW6001 and 3390 series Power Analyzers that delivers wide bandwidth and high accuracy testing across 3 or 4 channels of input. The option is ideal for applications requiring direct input connections when testing the power conversion efficiency of motors, primary and secondary side of inverters, hybrid and electric vehicles, and renewable energy equipment.
Key Features
- World-leading measurement bands and accuracy
- Wide-band DC to 3.5MHz, 50A AC/DC rated input
- ±0.04% power accuracy in combination with PW6001
- 120 dB CMRR (100 kHz)
- Full-rack size suitable for test/evaluation benches
- Current measurement option for PW6001, PW3390, 3390 Power Analyzers
Model No. (Order Code)
PW9100-03 | Discontinued, 3 ch |
---|---|
PW9100-04 | 4 ch |
The optimal device for testing inverters
For more reliable wideband high-accuracy measurements.
Delivering a direct-coupled type current testing tool that brings out the PW6001 POWER ANALYZER's maximum potential.The existing direct-input type power meter can be replaced easily.
Use two PW9100-03 devices (the 3ch models) for 6-channel measurements.
Basic specifications
Measurement line type | Isolated input, DCCT input | |||||
---|---|---|---|---|---|---|
Rated primary current | 50 A AC/DC | |||||
Number of input channels | PW9100-03: 3 channels PW9100-04: 4 channels |
|||||
Maximum input current | 60 A, within derating. However, up to ±200 A peak is allowable if within 20 ms (design value) | |||||
Amplitude and Phase accuracy | DC (±0.02 % rdg. ±0.007 % f.s.) 45 Hz < f ≤ 65 Hz (±0.02 % rdg. ±0.005 % f.s., Phase: ±0.1 deg.) Accuracy is defined to 1 MHz |
|||||
Output voltage | 2 V/50 A | |||||
Measurement terminals | Terminal block (with safety cover), M6 screws | |||||
Input resistance | 1.5 mΩ or less (50 Hz/60 Hz) | |||||
Input capacitance | Between measurement terminals and case (secondary side), 40 pF or less, defined at 100 kHz | |||||
Operating temperature and humidity | Temperature: 0°C to 40°C (32°F to 104°F), Humidity: 80% RH or less (no condensation) | |||||
Power supply | Power supply from PW6001, PW3390 | |||||
Dimensions and mass | 430 mm (16.93 in) W × 88 mm (3.46 in) H × 260 mm (10.24 in) D, Cable length: 0.8 m (2.62 ft) PW9100-03: 3.7 kg (130.5 oz), PW9100-04: 4.3 kg (151.7 oz) |
|||||
Included accessories | Instruction Manual ×1 |
Option A (1)
ME15W (12 pin) to PL23 (10 pin) connector
Option B (1)
Only 1 unit of CT9902 can be used at any one time.
5 m (16.41 ft) length, ME15W (12 pin) - ME15W (12 pin) connector
Option C (0)
Rack mount hardware
Made-to-order, for EIA/JIS
Contact your local Hioki distributor for more information