AC/DC AUTO-ZERO CURRENT SENSOR CT7736
Accurate, Long-term Recording and Easy Output Settings
Hioki clamp on meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. The CT7736 is a 600 A AC/DC Current Sensor that pairs with the detachable Display Unit CM7290 or CM7291 for convenient field testing, while delivering an extended temperature range and auto-zero adjustment to minimize drift due to wide temperature changes that occur during long-term testing.
Further extend the functionality of this system by connecting the Display Unit with a Hioki memory recorder or logger.
CAT IV 600 V
Key Features
- Accurately measure and record even when the temperature changes
- Ideal for site inspections by using detachable Display Unit
- Four output formats to output data to loggers or other devices (via Display Unit): WAVE, RMS, PEAK, Hz
Model No. (Order Code)
CT7736 | 600 A AC/DC, φ33 mm (1.30 in) |
---|
Connect to Recorders, Data loggers, and Oscilloscopes
Must be paired with the Display Unit CM7290 or CM7291 to operate as a standalone unit. Add an output cord to deliver signals to a data logger or Memory HiCorder for the following types of output:
• A DC or AC (up to 5 kHz/10 kHz) current waveform as-is (using WAVE mode for waveform output)
• An analog signal generated by converting the input waveform to a series of RMS values (using RMS mode for RMS output)
• An analog signal generated by detecting the current waveform’s peak value (using PEAK mode for peak output
• An analog waveform generated by detecting the frequency of the current waveform (using FREQ mode for frequency output)
Broad temperature range
A wide operating temperature range of -25°C to 65°C (-13°F to 149°F) lets you use the sensor even in sub-freezing temperatures and on hot summer days.
Take measurements without shifts in the zero-point, even during extended recording with temperature variations
Because temperature variations cause the zero-point to shift when using a conventional DC current sensor to measure DC current, it is necessary to perform zero-adjustment periodically when recording data over an extended period of time with such a sensor. This shortcoming is caused by the effects of the Hall element that conventional DC current sensors use to to detect current. Hioki’s new auto-zero current sensors incorporate a new switching-based offset cancellation circuit developed to address this problem. The new design minimizes zero-point shift, making it possible to record DC current values over an extended period of time without the need for periodic zero-adjustment.
Transfer data wirelessly using Bluetooth(R) to GENNECT Cross mobile app
Pair with the CM7291 Display Unit to send measurement data to a smartphone or tablet using Bluetooth® wireless technology. Use the GENNECT Cross dedicated app to display and review measured values and waveforms in real time.
Basic specifications
Rated measurement current | 600 A AC/DC | |||||
---|---|---|---|---|---|---|
Max. measurement current | 600 A (requires derating at frequency) |
|||||
Max. allowable peak input | 900 A peak | |||||
Bandwidth | DC to 5 kHz (-3dB) (When used in combination with CM7290 or CM7291: DC 3 Hz to 1 kHz) |
|||||
Typical phase accuracy | ±1.8 deg. (DC < f ≤ 66 Hz) | |||||
Output rate | 1 mV/A | |||||
Max. rated voltage to earth | AC/DC 600 V (CAT IV) AC/DC 1000 V (CAT III) |
|||||
Core diameter | φ 33 mm (1.30 in) or less | |||||
Output connectors | HIOKI PL 14 | |||||
Operating temperature range | -25 °C to 65 °C (-13 °F to 149 °F) | |||||
Dimensions and mass | 64 mm (2.52 in)W × 160 mm (6.30 in)H × 34 mm (1.34 in)D, 320 g (11.3 oz), Cable length 2.5 m (8.20 ft) | |||||
Included accessories | None |
Display, Output (9)
2 m (6.56 ft) length
5 m (16.41 ft) length
10 m (32.81 ft) length
20 m (65.62 ft) length
30 m (98.43 ft) length
50 m (164.06 ft) length
100 m (328.11 ft) length
Case (2)
For storing sensor ×1, CM7290 ×1, AC adapter ×1, and output cord
For storing sensor ×3, CM7290 ×1, AC adapter ×1, output cord, and 30 m extension cable
Output cord (2)
Connect to BNC terminal, 1.5 m (4.92 ft) length
Connect to terminal block, 1.5 m (4.92 ft) length
- On-site Inverter Measurement
- Measure Transient Voltage Waveforms
- Measure Periodical Instantaneous Voltage Drops
- Inspect the Stress on Factory UPS Caused by Voltage Dips
- Measure the High-Order Harmonic Voltage and Current of Power Lines
- Power Quality Survey of Solar Power Generation Systems
- Measure the Transient Voltage in Glowing Fluorescent Lights
- Measure Lightning-induced Voltage Dips in a Low-Voltage Circuit
- Measure Voltage Drop Caused by Wiring Impedance
- Verify the Energy Savings Created By Photovoltaic (PV) Systems
- Evaluate the Input/Output Characteristics of a Power Conditioner for Mega Solar Power Generation