What are the differences between the 4-channel analog units?

QThere are two types of 4-channel analog units for the Memory HiCorders. What are the differences between U8975 4ch Analog Unit and U8978 4ch Analog Unit?

A

Please refer to the comparison table below for U8975 and U8978.
The U8975 supports input voltages up to 200 V. The U8978 supports up to 40 V, but offers higher resolution.
Please select the model according to your application.

U8975U8978
Input / Number of channelsVoltage / 4 chVoltage / 4 ch
Sampling rate5 MS/s5 MS/s
A/D resolution16 bit
(minimum resolution: 125 μV)
16 bit
(minimum resolution: 3.125 μV)
DC accuracy±0.1% f.s.±0.3% f.s.
Range configuration4 V f.s. to 200 V f.s.100 mV f.s. to 40 V f.s.
Maximum input voltage200 V DC40 V DC
Maximum rated voltage to ground300V AC, 300 V DC (CAT II)30 V AC, 60 V DC
Input couplingDC, GNDDC, GND
Compatible modelsMR8848, MR6000 series, MR8740TMR8848, MR6000 series, MR8740T