FLYING PROBE TESTER FA1815-20
Improved efficiency and reliability take board production to the next level
NEW
With remarkable progress in IT technology driving the semiconductor industry forward, reliability and productivity have become indispensable. Flying probe testers have long been the industry standard tool for PCB inspection. However, as inspection demands grow more stringent, the FA1815-20 emerges as the next-generation flying probe tester, ready to meet the challenges of precision and speed head-on. Moreover, this tester introduces an innovative approach to insulation resistance inspection that minimizes some cautious users’ concern about board damage with high-voltage testing in high-resistance inspections. This advancement represents Hioki's commitment to providing market-leading solutions that contribute to societal progress.
Model No. (Order Code)
FA1815-20 |
---|
Specifications Overview
Number of arms | 4 (2 each, top and bottom) | |
---|---|---|
Compatible probes | 1172 series, CP1072 series, CP1073 series | |
Number of test steps | Max. 4,000,000 steps | |
Test parameters and measurement ranges | DC constant-current continuity measurement | 400.0 mΩ to 1.000 kΩ |
DC constant-current resistance measurement | 40.00 μΩ to 400.0 kΩ | |
DC constant-voltage resistance measurement | 4.000 Ω to 40.00 MΩ | |
Insulation resistance measurement | 1.000 kΩ to 100.0 GΩ | |
Low voltage insulation resistance measurement | 1.000 MΩ to 100.0 GΩ | |
AC constant-voltage capacitance measurement | 100.0 fF to 10.00 μF | |
Leakage current measurement | 1.000 μA to 100.0 mA | |
High-voltage resistance measurement | 1.000 kΩ to 100.0 GΩ | |
Capacitor insulation measurement | 1.000 kΩ to 250.0 MΩ | |
Open measurement | 4.000 Ω to 4.000 MΩ | |
Short measurement | 400.0 mΩ to 40.00 kΩ | |
Test parameters and measurement for component-embedded board tests | LSI connection test | 0.000 V to 12.00 V |
AC constant-voltage resistance measurement | 10.00 Ω to 10.00 kΩ | |
AC constant-voltage capacitance measurement | 10.00 pF to 100.0 μF | |
AC constant-voltage inductance measurement | 1.000 μH to 1.000 mH | |
Judgment range | -99.9% to +999.9% or absolute value | |
Movement resolution | XY: 0.1 μm/pulse; Z: 1 μm/pulse | |
Minimum pad pitch | Top surface: 34 μm (with CP1075-09) Bottom surface: 44 μm (with CP1075-09) |
|
Minimum pad size | Top surface: 4 μm square (with CP1075-09) Bottom surface: 14 μm square (with CP1075-09) |
|
Measurement speed | Max. 100 points/sec. (0.15 mm movements, 4-arm simultaneous probing, capacitance measurement) | |
Testable board size | Thickness : 1 mm (0.04 in.) to 12 mm (0.47 in.) Outer dimensions : 50 mm (1.97 in.) W × 50 mm (1.97 in.) D to 340 mm (13.39 in.) W × 340 mm (13.39 in.) D |
|
Maximum testable area | 340 mm (13.39 in.) W × 340 mm (13.39 in.) D | |
Clamp method | Flexible Fixture Vacuum Unit for Capacitance Test (Options) |
|
Air requirements | Primary-side pressure: 0.5 MPa to 0.99 MPa (dry air) Maximum consumption: 0.3 L/min. (ANR) |
|
Power supply | 200 V, 220 V, 230 V, 240 V AC single-phase (specified at time of order); 50/60 Hz; maximum power consumption: 5 kVA |
|
Dimensions and weight | 1355 mm (53.35 in.) W × 1190 mm (46.85 in.) H × 1265mm (49.8 in.) D(excluding protruding parts); 1100 kg ±50 kg (38800 oz. ±1763 oz.) |