DIFFERENTIAL PROBE P9000
Easily Connect to Hioki Memory HiCorders and HiLoggers for High Voltage Testing
Key Features
- Compact probe for CAT III 1000 V environments
- Wave mode: Observe instantaneous waveforms
- RMS mode: Observe RMS value waveforms
- Principal areas of use (*1)
- *1:List of principal areas of use
- 1. High-voltage battery circuits in EVs, HEVs, and other automobiles
- 2. High-voltage circuits in energy-related equipment such photovoltaic cells
- 3. Commercial power line circuits (480 V rms, etc.)
- 4. High-voltage surge noise from inverters, motors, solenoids, etc.
Model No. (Order Code)
P9000-01 | For the Memory HiCorder series, Wave only |
---|---|
P9000-02 | For the Memory HiCorder series, Wave/RMS |
Basic specifications
P9000-01 | P9000-02 | |||||
Measurement functions | Waveform monitor output only Frequency characteristics: DC to 100 kHz, -3 dB |
Waveform monitor output/AC RMS value output (switchable) Wave mode frequency characteristics: DC to 100 kHz, -3 dB RMS mode frequency characteristics: 30 Hz to 10 kHz; response time: 300 ms (rising) or 500 ms (falling) |
||||
Division ratio | 1000:1 or 100:1 (user selectable) | |||||
DC amplitude accuracy | ±0.5% f.s. (f.s. = 1.0 V; voltage division ratio: 1000:1) (f.s. = 3.5 V; voltage division ratio: 100:1) | |||||
RMS amplitude accuracy | n/a | ±1% f.s. (30 Hz to 1 kHz non-inclusive, sine wave), ±3% f.s. (1 kHz to 10 kHz, sine wave) | ||||
Input resistance, capacity | Between H and L: 10.5 MΩ, 5 pF or less (at 100 kHz) | |||||
Max. allowable input | 1000 V AC/DC | |||||
Max. rated voltage to earth | 1000 V AC/DC (CAT III) | |||||
Operating temperature | -40˚C (-40˚F) to 80˚C (176˚F) | |||||
Power supply | (1) AC Adapter Z1008 (100 to 240 V AC, 50/60 Hz), 6 VA (including AC adapter) or 0.9 VA (probe only) (2) USB bus power (5 V DC, USB Micro-B receptacle), 0.8 VA To prevent an electric shock, when supplying power from the USB-microB terminal, please supply from a device which USB's GND terminal of the source device is grounded. (3) External power supply (2.7 V to 15 V DC) |
|||||
Dimensions and mass | 128 mm (5.04 in)W × 36 mm (1.42 in)H × 22 mm (0.87 in)D, 170 g (6.0 oz), Cord length: Input: 70 cm (2.30 ft) ; output: 1.5 m (4.92 ft) | |||||
Included accessories | Instruction manual ×1, alligator clips ×2, carrying case ×1 |
Number of P9000 probes that can be used when power is supplied from the standard USB terminal of the Memory HiCorder
Main unit | Number of the P9000-01, P9000-02 connections | |||||
---|---|---|---|---|---|---|
MR8880 | 1 | |||||
MR8875 | 1 | |||||
MR8847A | 1 | |||||
MR8827 | 2 | |||||
MR8740 | 2 | |||||
MR8741 | 2 | |||||
MR8740T | 8 | |||||
MR6000, MR6000-01 | 6 (The USB terminal in the media box of MR6000 cannot be used) |
Power supplies (1)
100 V to 240 V AC
Input cable options (9)
Test Pin Set L4932 is required when using the Small Alligator Clip Set L4934.
Expands the length of L4930/4940, 1.5 m (4.92 ft) length
Attaches to the tip of the L4930/4940, CAT IV 600 V, CAT III 1000 V
Attaches to the tip of the L4932, L9207-10/DT4911, L9206, CAT III 300 V, CAT II 600 V
Attaches to the tip of the L4930/4940, CAT IV 600 V, CAT III 1000 V
Attaches to the tip of the L4930/4940, CAT III 600 V
Attaches to the tip of the L4930/4940, CAT III 1000 V
Attaches to the tip of the L4930/4940, CAT III 600 V
Attaches to the tip of the L4930/4940, CAT III 600 V
Attaches to the tip of the banana plug cable, Red/Black: 1 each, 185 mm (7.28 in.) length, CAT II 1000 V
Output cables (2)
30 cm (0.98 ft) length, covert BNC to wire
2.4 m (7.87 ft) length, covert BNC to wire