F/V UNIT 8940
Frequency, Rotation, Pulse, and Current waveforms measurement
Discontinued
Key Features
- Frequency, Integration, Pulse duty ratio, Voltage, and Current measurement (using with optional current sensor)
- 12-bit A/D resolution measurement
- Pulse counting for the encoder
- For the motor rotation, pules integration, duty ratio, and pulse width measurement
Model No. (Order Code)
8940 | For the 8860-50, 8861-50, and similar products |
---|
Note: This module must be used with the Memory HiCorder. Input cords and current sensors are not supplied. Please purchase the appropriate sensors for the intended application.
Basic specifications
Accuracy guaranteed: 1 year
Measurement functions | Number of channels: 2, for voltage input based frequency measurement, integration, pulse duty ratio, current (with optional clamp-on sensor), and voltage measurement | |||||
---|---|---|---|---|---|---|
Input connectors | Metallic BNC connector (input impedance 1MΩ, input capacitance 60pF), sensor connector (dedicated connector for clamp-on sensor via conversion cable, common ground with recorder), Max. rated voltage to earth: 30Vrms or 60V DC (with input isolated from the unit, the maximum voltage that can be applied between input channel and chassis and between input channels without damage) | |||||
Compatible current sensors | 9270, 9271, 9272, 9277, 9278, 9279, 3273, 3273-50 | |||||
Measurement range | Frequency: DC to 100kHz, with 0.05Hz to 5kHz/DIV, 11 ranges, 5 (r/min) to 500 (r/min)/DIV, 5ranges, P50Hz (40 to 60Hz), P60Hz (50 to 70Hz) * Power line frequency measurement requires the DIFFERENTIAL PROBE 9322 or PT 9303, Accuracy: ±0.2% of full scale (except 5kHz/DIV range), ±0.7% of full scale (5kHz/DIV range), ±0.032Hz (P50Hz, P60Hz range) Integration: DC to 90kHz, with 5counts to 500kcounts/DIV, 11 ranges Pulse duty ratio: 10Hz to 100kHz, with 100% of full scale, 1 range, Accuracy: ±1% of full scale (10Hz to 10kHz) Threshold: -10 to +10V (settable in 0.2V steps) Full scale: 20DIV, Max. allowable input: 30Vrms or 60V DC (the maximum voltage that can be applied across input pins without damage) |
|||||
Measurement range | Voltage: 0.5mV to 2V/DIV, 12 ranges Current: 5mA to 100A/DIV, 10 ranges, using current sensor (powered from the 8940, max. 4 sensors total) DC amplitude accuracy: ±0.4% of full scale, zero position ±0.15% of full scale (current measurement accuracy dependent on sensor accuracy/characteristics) Frequency characteristics: DC to 400kHz ±3dB Full scale: 20DIV, Max. allowable input: 30Vrms or 60V DC (the maximum voltage that can be applied across input pins without damage) |
|||||
Measurement resolution | 1/80 of measurement range (installed in 8860 series, excluding current range when using 9279) | |||||
Highest sampling rate | 1MS/s (2-channel simultaneous sampling), (frequency/duty ratio measurement: 1.125μs cycle) | |||||
Other functions | Voltage input pull-up: ON (10kΩ)/OFF, input coupling: DC, GND, AC (voltage/current), DC (others), low-pass filter: 5Hz/500Hz/5kHz/100kHz | |||||
Dimensions and mass | 170 mm (6.69 in)W × 20 mm (0.79 in)H × 148.5 mm (5.85 in)D, 300 g (10.6 oz) | |||||
Included accessories | None |