CLAMP ON SENSOR 9694
For measuring load current, voltage output sensor 5 A AC
Hioki current sensors are best-in-class devices for use with power meters and PQAs. The 9694 is a 5A AC clamp sensor with voltage output for measuring load current.
CAT III 300V
Key Features
- For inverter devices or commercial power lines
- For measuring the secondary side of 5A CTs
- Fits in narrow spaces due to compact design
Model No. (Order Code)
9694 | For the PW3360/65, 3169, PW3198 and similar products |
---|
Note: Supports power quality analyzers, power meters and other data acquisition equipment with voltage input
Basic specifications
Accuracy guaranteed: 1 year
Rated measurement current | 5 A AC | |||||
---|---|---|---|---|---|---|
Max. measurement current | Continuous 50 A (45 to 66 Hz) | |||||
Output rate | 10 mV AC/ A | |||||
Amplitude accuracy (45 to 66 Hz) |
±0.3 % rdg. ±0.02 % f.s. | |||||
Phase accuracy | ±2° (45 Hz to 5 kHz) | |||||
Amplitude frequency characteristics | Within ±1% at 40 Hz - 5 kHz (deviation from amplitude accuracy) | |||||
Max. rated voltage to earth | 300 V AC rms or less | |||||
Measurable conductor diameter | φ 15 mm (0.59 in) or less | |||||
Operating temperature and humidity | 0°C to 50°C (32°F to 122°F), 80% RH or less (no condensation) | |||||
Dustproofness and waterproofness | N/A | |||||
Dimensions and mass | 46 mm (1.81 in)W × 135 mm (5.31 in)H × 21 mm (0.83 in)D, 230 g (8.1 oz) Cord length 3 m (9.84 ft), Output terminal: BNC |