AC/DC CLAMP METER CM4376 (Bluetooth®)
Easily Get Into Tight Spaces
Innovative Jaw Provides Remarkable Accessibility
Discontinued
Hioki clamp on meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. The CM4376 is a 1000A AC/DC True RMS clamp meter that features a uniquely designed slim jaw that lets you easily get into the narrow gaps between cables in crowded electrical distribution boxes without fear of damaging the cables or the clamp meter. The broad -25°C to 65°C operating temperature range and IP54 dustproof and waterproof enclosure to enable professionals to work quickly in challenging situations including the development, repair, and maintenance of equipment and devices such as electric vehicles. Additionally, the high-voltage DC measurement capability of up to 1700 V (*1) is ideal for the clamp maintenance inspections of electrical and solar power equipment. Finally, built-in Bluetooth wireless technology lets you send measured values to a smartphone or tablet, display waveforms in real time, and create reports right on site.
CAT IV 600 V, CAT III 1000 V
Made for Real-World Situations Uncompromising Design
Panel overcrowding is commonly found in many power distribution breakers and termination boxes. The newly designed thin sensor gets into even the most limited spaces. Eliminate the issues of trying to find the right wire or forcing the clamp around thick cables.
Key Features
- Easily get into tight spaces between cables thanks to thin sensor structure
- Measure DC voltages of up to 1700 V (*1) for open voltage inspections of solar panels
- Simultaneously measure inrush current in RMS and crest values
- Measure up to 1000 A
- Automatic AC/DC function helps boost work efficiency
- Expanded -25°C to 65°C operating temperature range
- Send measured values to a smartphone or tablet using Bluetooth® wireless technology (CM4376)
- *1:Your instrument can be used to measure voltages in excess of 1000 V DC if and only if both of the following conditions are satisfied:
- 1. The circuit under measurement is isolated from the commercial power grid.
- 2. The circuit under measurement is isolated from ground.
- e.g.: When measuring the no-load voltage of an ungrounded PV panel
- Do not use the instrument with circuits whose terminal-to-ground voltage exceeds 1000V. Doing so may result in electric shock.
Model No. (Order Code)
CM4376 | Built in Bluetooth(R) wireless technology |
---|
Instantly create reports by a free app (GENNECT Cross)
GENNECT Cross, a free app designed specifically for use with Hioki measuring instruments, lets you check and manage measurement results and create reports.
The software provides a range of functionality that helps manage data in the field, including photographing measurement sites, placing measurement results on photographs, and saving hand written memos.
Damage-resistant jaws! Guaranteed for 30,000 open-close cycles
The new and improved design features stronger jaws (the current sensor portion of the instrument) and a dramatic boost in the duration of the warranty from 10,000 to 30,000 open-close cycles to ensure the instrument will provide even more years of reliable use. The CM4375, CM4376, CM4141 and CM4142 deliver the dual functionality of ease of clamping and resistance to damage.
Inrush (Rush current): Assess transient currents at motor startup
The CM4000 Series can simultaneously measure inrush current in RMS as well as maximum crest values at motor startup and for welding currents.
The clamp meters automatically detect the duration of the inrush current (which can range from several dozen milliseconds to several hundred milliseconds) and measure the current during that interval, enabling them to yield more accurate
measurements than standard clamp-on meters whose measurement interval is fixed to 100 ms.
Basic specifications
DC Current range | 1000 A, (Max. display 999.9 A) , Basic accuracy: ±1.3% rdg. ±0.3 A (at 30.1 A - 999.9 A) |
---|---|
AC Current range | 1000 A (Max. display 999.9 A, 10 Hz to 1 kHz, True RMS), Basic accuracy 45-66 Hz: ±1.3% rdg. ±0.3 A (at 30.1 A - 900.0 A) |
Crest factor | 1.5 |
DC+AC Current range | 1000 A (DC, 10 Hz to 1 kHz, True RMS), Basic accuracy DC, 45-66 Hz: ±1.3% rdg. ±1.3 A (at 30.1 A - 900.0 A) |
DC Power range | 0.0 VA to 1700 kVA (Automatically switched based on voltage range), Basic accuracy: ±2.0% rdg. ±20 dgt. |
DC Voltage range | 600.0 mV to 1700 V (*1), 5 ranges, Basic accuracy: ±0.5% rdg. ±0.5 mV (at 600 mV) |
AC Voltage range | 6.000 V to 1000 V, 5 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy 45 - 66 Hz: ±0.9% rdg. ±0.013 V (at 6 V) |
DC+AC Voltage range | 6.000 V to 1000 V, 5 ranges, Basic accuracy DC, 45-66 Hz: ±1.0% rdg. ±0.023 V (at 6 V) |
Resistance range | 600.0 Ω to 600.0 kΩ, 4 ranges, Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω) |
Electrostatic capacity range | 1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF) |
Frequency range | 9.999 Hz to 999.9 Hz, 3 ranges, Basic accuracy: ±0.1% rdg. ±0.003 Hz (at 9.999 Hz) |
Temperature (K) | -40°C to 400°C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0°C |
Other functions | Automatic AC/ DC detection, DC current and DC voltage polarity detection function, MAX/ MIN/ AVG/ PEAK MAX/ PEAK MIN value display, Low-pass filter function, Display value hold, Auto hold, Backlight, Auto power save, Buzzer sound, Zero-adjustment |
Dustproof, waterproof | IP54 (Storage or measurement of current of an insulated conductor) |
Interface | Bluetooth® 4.0LE, Supported devices: iOS, Android™ smartphone/tablet GENNECT Cross (free downloadable app) : display measured values and waveforms, or other |
Power supply | LR03 Alkaline battery ×2, Continuous use: 40 hr (Backlight OFF, Bluetooth® OFF), 20 hr (Backlight OFF, Bluetooth® ON) |
Core jaw diameter | φ34 mm (1.34 in) |
Smallest dimension of jaw cross-section | 9.5 mm (0.37 in) (Range value of 44 mm (1.73 in) from the tip of the jaw) |
Dimensions and mass | 65 mm (2.56 in) W × 242 mm (9.53 in) H × 35 mm (1.38 in) D mm, 330 g (11.6 oz) |
Included accessories | Test Lead L9207-10, Carrying Case C0203, LR03 Alkaline battery ×2, Instruction Manual ×1, CM4376: Precautions Concerning Use of Equipment that Emits Radio Waves ×1 |
- *1:Your instrument can be used to measure voltages in excess of 1000 V DC if and only if both of the following conditions are satisfied:
- 1. The circuit under measurement is isolated from the commercial power grid.
- 2. The circuit under measurement is isolated from ground.
- e.g.: When measuring the no-load voltage of an ungrounded PV panel
- Do not use the instrument with circuits whose terminal-to-ground voltage exceeds 1000V. Doing so may result in electric shock.
Countries and regions where wireless operation is currently supported (CM4376)
Countries and regions where wireless operation is currently supported | Austria, Bangladesh, Belgium, Bulgaria, Canada, Chile, Colombia, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Georgia, Germany, Greece, Hong Kong, Hungary, Iceland, Ireland, Israel, Italy, Japan, Kenya, Latvia, Liechtenstein, Lithuania, Luxembourg, Macao, Malta, Myanmar, Netherlands, Norway, Peru, Poland, Portugal, Romania, Singapore, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey, United Kingdom, United States, Viet Nam | |||||
---|---|---|---|---|---|---|
Note | Use of devices that emit radio radiation requires approval in the country of use. Thus, use of the instrument in a country or region where they have not been approved may be subject to penalty as a violation of law. |
Test leads (2)
L9207-10 is a bundled accessory
Cable length: 90 cm (2.95 ft.)
Cable length 95 cm (37.4 in.), Integrated cap and protective finger guard
Options for Test leads (for the L9207-10, L9300) (2)
Attach L9207-10 with the cap removed.
Slide the guard of L9300 and attach as measurement category II.
Attaches to the tip of the Test Lead L9207-10/DT4911, L9206, 60V DC/ 30V AC
Attaches to the tip of the L4932, L9207-10/DT4911, L9206, CAT III 300 V, CAT II 600 V
Options for Test leads (for the L4930) (11)
Test Pin Set L4932 is required when using the Small Alligator Clip Set L4934
1.2 m (3.94 ft) length, CAT IV 600 V, CAT III 1000 V
Expands the length of L4930/4940, 1.5 m (4.92 ft) length
Attaches to the tip of the L4930/4940, CAT IV 600 V, CAT III 1000 V
Attaches to the tip of the L4932, L9207-10/DT4911, L9206, CAT III 300 V, CAT II 600 V
Attaches to the tip of the L4930/4940, CAT IV 600 V, CAT III 1000 V
Attaches to the tip of the L4930/4940, CAT III 600 V
Attaches to the tip of the L4930/4940, CAT III 1000 V
Attaches to the tip of the L4930/4940, CAT III 600 V
Attaches to the tip of the L4930/4940, CAT III 600 V
Attaches to the tip of the banana plug cable, Red/Black: 1 each, 185 mm (7.28 in.) length, CAT II 1000 V
Attaches to the tip of voltage cord, φ11 mm (0.43 in), compatible M6 pan screws
Temperature measurement (1)
K type, tip exposed, 0.5 mm (0.02 inch) diameter, 80 cm (2.62 ft) length, -40°C to 260°C (-40°F to 500°F), tolerance ±2.5 °C
Other options (1)
Bundled accessory