AC/DC CLAMP METER CM4376 (Bluetooth®)

Easily Get Into Tight Spaces
Innovative Jaw Provides Remarkable Accessibility

Hioki clamp on meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. The CM4376 is a 1000A AC/DC True RMS clamp meter that features a uniquely designed slim jaw that lets you easily get into the narrow gaps between cables in crowded electrical distribution boxes without fear of damaging the cables or the clamp meter. The broad -25°C to 65°C operating temperature range and IP54 dustproof and waterproof enclosure to enable professionals to work quickly in challenging situations including the development, repair, and maintenance of equipment and devices such as electric vehicles. Additionally, the high-voltage DC measurement capability of up to 1700 V (*1) is ideal for the clamp maintenance inspections of electrical and solar power equipment. Finally, built-in Bluetooth wireless technology lets you send measured values to a smartphone or tablet, display waveforms in real time, and create reports right on site.

CAT IV 600 V, CAT III 1000 V

Made for Real-World Situations Uncompromising Design

Panel overcrowding is commonly found in many power distribution breakers and termination boxes. The newly designed thin sensor gets into even the most limited spaces. Eliminate the issues of trying to find the right wire or forcing the clamp around thick cables.

Key Features

  • Easily get into tight spaces between cables thanks to thin sensor structure
  • Measure DC voltages of up to 1700 V (*1) for open voltage inspections of solar panels
  • Simultaneously measure inrush current in RMS and crest values
  • Measure up to 1000 A
  • Automatic AC/DC function helps boost work efficiency
  • Expanded -25°C to 65°C operating temperature range
  • Send measured values to a smartphone or tablet using Bluetooth® wireless technology (CM4376)
  • *1:Your instrument can be used to measure voltages in excess of 1000 V DC if and only if both of the following conditions are satisfied:
  • 1. The circuit under measurement is isolated from the commercial power grid.
  • 2. The circuit under measurement is isolated from ground.
  • e.g.: When measuring the no-load voltage of an ungrounded PV panel
  • Do not use the instrument with circuits whose terminal-to-ground voltage exceeds 1000V. Doing so may result in electric shock.

Model No. (Order Code)

CM4376 Built in Bluetooth(R) wireless technology
For the latest information about countries and regions where wireless operation is currently supported, please see the "Specifications" tab.
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by HIOKI E.E. CORPORATION is under license.
Android, Google Play and the Google Play logo are trademarks of Google Inc.
iOS is a registered trademark of Cisco Technology, Inc. and/or its affiliates in the United States and certain other countries.
iPhone, iPad, iPad mini, iPad Pro and iPod touch are trademarks of Apple Inc.
Apple and the Apple logo are trademarks of Apple Inc. App Store is a service mark of Apple Inc.

Data can be downloaded to tablets and smartphones using Hioki’s dedicated free app "GENNECT Cross," available from the Google Play or App Store.

Instantly create reports by a free app (GENNECT Cross)

GENNECT Cross, a free app designed specifically for use with Hioki measuring instruments, lets you check and manage measurement results and create reports.
The software provides a range of functionality that helps manage data in the field, including photographing measurement sites, placing measurement results on photographs, and saving hand written memos.

Click here for details about GENNECT Cross

Damage-resistant jaws! Guaranteed for 30,000 open-close cycles

The new and improved design features stronger jaws (the current sensor portion of the instrument) and a dramatic boost in the duration of the warranty from 10,000 to 30,000 open-close cycles to ensure the instrument will provide even more years of reliable use. The CM4375, CM4376, CM4141 and CM4142 deliver the dual functionality of ease of clamping and resistance to damage.

Inrush (Rush current): Assess transient currents at motor startup

The CM4000 Series can simultaneously measure inrush current in RMS as well as maximum crest values at motor startup and for welding currents.
The clamp meters automatically detect the duration of the inrush current (which can range from several dozen milliseconds to several hundred milliseconds) and measure the current during that interval, enabling them to yield more accurate
measurements than standard clamp-on meters whose measurement interval is fixed to 100 ms.

Basic specifications

Accuracy guaranteed: 1 year
DC Current range 1000 A, (Max. display 999.9 A) , Basic accuracy: ±1.3% rdg. ±0.3 A (at 30.1 A - 999.9 A)
AC Current range 1000 A (Max. display 999.9 A, 10 Hz to 1 kHz, True RMS), Basic accuracy 45-66 Hz: ±1.3% rdg. ±0.3 A (at 30.1 A - 900.0 A)
Crest factor 1.5
DC+AC Current range 1000 A (DC, 10 Hz to 1 kHz, True RMS), Basic accuracy DC, 45-66 Hz: ±1.3% rdg. ±1.3 A (at 30.1 A - 900.0 A)
DC Power range 0.0 VA to 1700 kVA (Automatically switched based on voltage range), Basic accuracy: ±2.0% rdg. ±20 dgt.
DC Voltage range 600.0 mV to 1700 V (*1), 5 ranges, Basic accuracy: ±0.5% rdg. ±0.5 mV (at 600 mV)
AC Voltage range 6.000 V to 1000 V, 5 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy 45 - 66 Hz: ±0.9% rdg. ±0.013 V (at 6 V)
DC+AC Voltage range 6.000 V to 1000 V, 5 ranges, Basic accuracy DC, 45-66 Hz: ±1.0% rdg. ±0.023 V (at 6 V)
Resistance range 600.0 Ω to 600.0 kΩ, 4 ranges, Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)
Electrostatic capacity range 1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)
Frequency range 9.999 Hz to 999.9 Hz, 3 ranges, Basic accuracy: ±0.1% rdg. ±0.003 Hz (at 9.999 Hz)
Temperature (K) -40°C to 400°C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0°C
Other functions Automatic AC/ DC detection, DC current and DC voltage polarity detection function, MAX/ MIN/ AVG/ PEAK MAX/ PEAK MIN value display, Low-pass filter function, Display value hold, Auto hold, Backlight, Auto power save, Buzzer sound, Zero-adjustment
Dustproof, waterproof IP54 (Storage or measurement of current of an insulated conductor)
Interface Bluetooth® 4.0LE, Supported devices: iOS, Android™ smartphone/tablet
GENNECT Cross (free downloadable app) : display measured values and waveforms, or other
Power supply LR03 Alkaline battery ×2, Continuous use: 40 hr (Backlight OFF, Bluetooth® OFF), 20 hr (Backlight OFF, Bluetooth® ON)
Core jaw diameter φ34 mm (1.34 in)
Smallest dimension of jaw cross-section 9.5 mm (0.37 in) (Range value of 44 mm (1.73 in) from the tip of the jaw)
Dimensions and mass 65 mm (2.56 in) W × 242 mm (9.53 in) H × 35 mm (1.38 in) D mm, 330 g (11.6 oz)
Included accessories Test Lead L9207-10, Carrying Case C0203, LR03 Alkaline battery ×2, Instruction Manual ×1, CM4376: Precautions Concerning Use of Equipment that Emits Radio Waves ×1
  • *1:Your instrument can be used to measure voltages in excess of 1000 V DC if and only if both of the following conditions are satisfied:
  • 1. The circuit under measurement is isolated from the commercial power grid.
  • 2. The circuit under measurement is isolated from ground.
  • e.g.: When measuring the no-load voltage of an ungrounded PV panel
  • Do not use the instrument with circuits whose terminal-to-ground voltage exceeds 1000V. Doing so may result in electric shock.

Countries and regions where wireless operation is currently supported (CM4376)

Last update: October 2021
Countries and regions where wireless operation is currently supported Austria, Bangladesh, Belgium, Bulgaria, Canada, Chile, Colombia, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Georgia, Germany, Greece, Hong Kong, Hungary, Iceland, Ireland, Israel, Italy, Japan, Kenya, Latvia, Liechtenstein, Lithuania, Luxembourg, Macao, Malta, Myanmar, Netherlands, Norway, Peru, Poland, Portugal, Romania, Singapore, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey, United Kingdom, United States, Viet Nam
Note Use of devices that emit radio radiation requires approval in the country of use. Thus, use of the instrument in a country or region where they have not been approved may be subject to penalty as a violation of law.

Test leads (2)

L9207-10 is a bundled accessory

Options for Test leads (for the L9207-10, L9300) (2)

Attach L9207-10 with the cap removed.
Slide the guard of L9300 and attach as measurement category II.

Options for Test leads (for the L4930) (11)

Test Pin Set L4932 is required when using the Small Alligator Clip Set L4934

Temperature measurement (1)

Other options (1)

Bundled accessory