WIRELESS ADAPTER Z3210

Get connected to create and share graphical reports in a flash!

Easy! Just connect the Z3210 Wireless Adapter to your Hioki compatible instrument, to make it Bluetooth® ready.

Easy! Just connect the Z3210 to a Hioki compatible instrument!

Wirelessly connect Hioki-compliant instruments with a simple connection. Transmit measured values to your tablet or smartphone.

Key Features

  • Increase your work efficiency, by eliminating human errors from manual reporting
  • Transfer readings on instruments to easy-to-read graphical reports to prove integrity
  • Increase your work productivity & save costs!
  • Provide additional new functions for Hioki instruments such as waveform display & more!
  • Compliance with wireless regulations in more than 50 countries and regions

Model No. (Order Code)

Z3210
Note) Z3210 cannot be used by itself. Wireless communication will be possible by connecting to a compatible measuring instrument.

Data can be downloaded to tablets and smartphones using Hioki’s dedicated free app "GENNECT Cross," available from the Google Play or App Store.

Easily transfer measurement data to an Excel® file

Measurement data can be directly transferred and input to file forms created by Excel®.
(Available in Ver. 2.10 and later)

Excel® Direct Input function allows you to input measurement values directly and automatically into an Excel® file once the instrument's auto-hold function is activated.

Please download and try using our sample forms (demo sheets) from the [Downloads] tab.

Instantly create reports by a free app (GENNECT Cross)

GENNECT Cross, a free app designed specifically for use with Hioki measuring instruments, lets you check and manage measurement results and create reports.
The software provides a range of functionality that helps manage data in the field, including photographing measurement sites, placing measurement results on photographs, and saving hand written memos.

Click here for details about GENNECT Cross

Supports labor savings by preventing transcription errors

Previously, measured values were recorded by hand and then they were typed at the office.
By making measurements wireless, it will prevent transcription errors from paper to PC, save labor and reduce the work hours.

Compliance with wireless regulations in more than 50 countries and regions

Even wireless technologies with low signal strength must meet the regulations of each country.
Z3210 complies with wireless regulations in more than 50 countries and regions and does not violate the regulations when it is used at the countries and regions.

Compatible products

Compatible products will be gradually increased.
See "Options" for the latest information of supported instruments.

For those who are developing apps

For communication commands, please contact us from below.

Contact Form

Basic specifications

Operating environment Indoors, pollution degree 2, operable at an altitude
specified in specifications of each measuring instrument to which the adapter is attached
Operating temperature and humidity
(Storage temperature and humidity)
-30℃ (-22℉) to 70℃ (158℉), 90% RH or less (no condensation)
Standards ・Safety: EN61010
・RF: EN300 328
・RF EMC: EN301 489-1, EN301 489-17
・Exposure: EN62479
Maximum attaching/detaching count 5000 times (Can be switched between compatible measuring instruments)
GENNECT Cross App confirmed compatible OSs iOS 13 or later, Android 9 or later, Bluetooth® 4.0 or later
Excel® Direct Input confirmed compatible OSs Windows 10, iOS 13 or later, Android 9 or later, Bluetooth® 4.0 or later
Bluetooth® communication distance About 10 m (line-of-sight distance)
Product warranty period 3 years (depending on your tablet/smartphone, you may not be able to connect)
Dimensions and mass Approx. 16.4 mm (0.65in)W × 6.7 mm (0.26in)H × 15.6 mm (0.61in)D, 1.5 g (0.05 oz.)
Included accessory Instruction manual

Countries and regions where wireless operation is currently supported (Z3210)

Last update: April 2024
Countries and regions where wireless operation is currently supported Argentina, Australia, Austria, Bangladesh, Belgium, Brazil, Bulgaria, Canada, Chile, China, Colombia, Croatia, Cyprus, Czech Republic, Denmark, Ecuador, Egypt, El Salvador, Estonia, Fiji, Finland, France, Georgia, Germany, Greece, Hong Kong, Hungary, Iceland, India, Indonesia, Ireland, Israel, Italy, Japan, Kenya, Korea, Kuwait, Latvia, Liechtenstein, Lithuania, Luxembourg, Macao, Malaysia*, Malta, Mexico*, Myanmar, Netherlands, New Caledonia, New Zealand, Norway, Oman*, Pakistan, Peru, Philippines, Poland, Portugal, Romania, Saudi Arabia, Singapore, Slovakia, Slovenia, Spain, Sweden, Switzerland, Taiwan, Thailand, Turkey, United Arab Emirates (UAE), United Kingdom, United States, Viet Nam

* The approval is valid for specific distributor or importer only. Please contact your authorized Hioki distributor or reseller for details.
Note Use of devices that emit radio radiation requires approval in the country of use. Thus, use of the instrument with the adapter attached in a country or region where they have not been approved may be subject to penalty as a violation of law.

Compatible products (18)