AC/DC CURRENT SENSOR 9709
High Precision DC to 100 kHz/500A AC/DC Pass-through Current Sensor with ±0.05% Basic Accuracy
Discontinued
Conversion cable is required depending on the compatible product.
Hioki pass-through AC/DC current sensors are best-in-class devices for use with power meters, Memory HiCorders and high performance oscilloscopes. The 9709 is a DC to 100 kHz/500 A sensor, ideal for capturing current signals from switching power supplies, inverters, power conditioners, etc.
CAT III 1000 V
Key Features
- Super high precision, ±0.05% amplitude accuracy, ±0.2° phase accuracy
- DC to 100 kHz bandwidths with excellent frequency characteristics
- Ideal for evaluation of solar power generation and fuel cells to measure battery charge and discharge and the secondary side of inverters
- For observing waveforms to be used with the oscilloscopes or Memory HiCorders (use with SENSOR UNIT)
Model No. (Order Code)
9709 | Discontinued, 500 A AC/DC, PL23 terminal |
---|
Basic specifications
Rated current | 500 A AC/DC | |||||
---|---|---|---|---|---|---|
Max. allowable input | 700 Arms (1000 Apeak, requires derating at frequency) |
|||||
Frequency characteristics | Amplitude: DC to 100 kHz Phase: DC to 100 kHz |
|||||
Amplitude and Phase accuracy | DC (±0.05 % rdg. ±0.01 % f.s.) 45 Hz ≤ f ≤ 66 Hz (±0.05 % rdg. ±0.01 % f.s., Phase: ±0.2°) Defined to 100 kHz |
|||||
Output voltage rate | 2 V /rated current value (voltage output with the Sensor Unit, use with a device having a 1 MΩ input resistance or higher) |
|||||
Max. rated voltage to earth | 1000 V AC/DC (50/60 Hz, CAT III) | |||||
Core diameter | φ 36 mm (1.42 in) | |||||
Operating temperature, humidity | 0°C to +50°C (32°F to 122°F) 80% rh or less (with no condensation) |
|||||
Power supply | ±11 V to ±15 V DC (Power suppled via the Sensor Unit, which supports 100 to 240 V AC) | |||||
Power consumption | 5 VA max. (at 500 A/55 Hz, ±12 V power requirement) |
|||||
Dimensions and mass | 160 mm (6.30 in)W × 112 mm (4.41 in)H × 50 mm (1.97 in)D, 850 g (30.0 oz), cord length: 3 m (9.84 ft) | |||||
Accessories | Instruction manual ×1, Mark bands ×6 |
Compatible models: 9709, 9709-05
Compatible models | 9709 | 9709-05 | ||||
---|---|---|---|---|---|---|
Power Analyzer PW6001, PW3390 |
△ (Requires CT9900) | OK | ||||
Power Analyzer 3390 |
OK | △ (Requires CT9901) | ||||
Power HiTester 3193 series |
OK | △ (Requires CT9901) | ||||
Current Unit 8971 |
△ (Requires the 9318) | △ (Requires the 9318, CT9901) | ||||
F/V Unit 8940 |
△ (Requires the 9318, 9705) | △ (Requires the 9318, 9705, CT9901) |
Options A (5)
Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length
Cord has metallic BNC connectors at both ends, use at metallic terminal, 1.5 m (4.92 ft) length
Options B (1)
The CT9903 connects up to 2 cables in series, Cannot be used in combination with the 9277 to 9279
Convert PL23 (10-pin) terminal to ME15W (12-pin) terminal
Options C (2)
The CT9902 connects up to 2 cables in series
ME15W (12 pin) to PL23 (10 pin) connector
5 m (16.41 ft) length, ME15W (12 pin) - ME15W (12 pin) connector
Options D (1)
For connecting to the F/V Unit 8940 or Current Unit 8971
To connect the CT6841-6846, CT6865/63/62, 9709, 9272-10 to the 8971/40/51, 38 cm (14.96 in) length