AC/DC CURRENT SENSOR CT6875
Beyond High-Accuracy Measurement
Discontinued
Hioki pass-through AC/DC current sensors are best-in-class devices for use with power analyzers, Memory HiCorders and high performance oscilloscopes. The CT6875 is a DC to 2 MHz/500 A sensor, ideal for testing inverter efficiency, inverter output power, reactor or transformer loss.
The sensor uses flux gate detection within the zero flux method to deliver outstanding linear properties, enabling it to maintain high precision even at low current levels.
CAT III 1000 V
Use with an instrument with a high input impedance of 1 MΩ or higher.
Key Features
- Combined accuracy with HIOKI power analyzer PW8001, PW6001 and PW3390 is specified. For details of combined accuracy, refer to the instruction manual.
- Strengthened shield improves noise resistance to accurately measure current buried in noise
- Flat frequency characteristics and CMRR performance to achieve high accuracy measurement
- More enhanced environmental resistance performance than ever before with operating temperature range of -40 to 85°C
- Good frequency characteristics over wide band of DC to 2 MHz (amplitude) and DC to 1 MHz (phase)
- Ideal for advanced fields such as photovoltaics and fuel cells to evaluate the charge / discharge of batteries and secondary side of inverters
- Connect with oscilloscopes or Hioki Memory HiCorders (using SENSOR UNIT) to monitor waveforms
Model No. (Order Code)
CT6875 | 500 A AC/DC, ME15W terminal, 3 m (9.84 ft) cable length |
---|---|
CT6875-01 | 500 A AC/DC, ME15W terminal, 10 m (32.81 ft) cable length |
Basic specifications
Rated current | 500 A AC/DC | |||||
---|---|---|---|---|---|---|
Max. allowable input | Within the derating range, up to ±1500 Apeak (design value) allowed at 40°C or less for 20 ms or less | |||||
Frequency bandwidth | Amplitude: DC to 2 MHz (CT6875A), DC to 1.5 MHz (CT6875A-1) Phase: DC to 1 MHz |
|||||
Basic accuracy | (DC, 45 Hz ≤ f ≤ 66 Hz) Amplitude: ±0.04 % rdg. ±0.008 % f.s., Phase: ±0.08° | |||||
Output voltage rate | 4 mV / A rated (This device outputs AC+DC voltage via the Sensor Unit) | |||||
Max. rated voltage to earth | 1000 V AC/DC (50/60 Hz, CAT III ) | |||||
Core diameter | φ 36 mm (1.42 in) | |||||
Operating temperature, humidity | -40°C to +85°C (-40°F to 185°F), 80% RH or less (with no condensation) | |||||
Power supply | Power suppled via the Power Analyzer PW8001, PW6001, PW3390, Sensor Unit CT9555, CT9556, CT9557, or 3CH CURRENT UNIT U8977 | |||||
Max. rated power | 7 VA max. (at 500 A/55 Hz) | |||||
Dimensions and mass | 160 mm (6.30 in)W × 112 mm (4.41 in)H × 50 mm (1.97 in)D, CT6875A: 850 g (30 oz), cable length 3 m (9.84 ft), CT6875A-1: 1150 g (40.6 oz), cable length 10 m (32.81 ft) | |||||
Included accessories | Instruction Manual ×1, Mark bands ×6, Operating Precautions ×1 |
Compatible models
Compatible models | CT6875A | |||||
---|---|---|---|---|---|---|
Power Analyzer PW8001, PW6001, PW3390 |
Ok | |||||
Power Analyzer 3390 |
Attention (Requires CT9901) | |||||
Power HiTester 3193 series |
Attention (Requires CT9901) | |||||
Current Unit 8971 |
Attention (Requires the 9318, CT9901) |
External power supply, Connection cord (5)
Compatible products PW3335, PW3336, PW3337, MR6000, MR8847A, MR8827, MR8740T, MR8740, MR8741, MR8870, MR8880, MR8875
Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length
Cord has metallic BNC connectors at both ends, use at metallic terminal, 1.5 m (4.92 ft) length
Conversion/Extension cables (2)
The CT9902 connects up to 2 cables in series
ME15W (12 pin) to PL23 (10 pin) connector
5 m (16.41 ft) length, ME15W (12 pin) - ME15W (12 pin) connector