Search Results
Results of search is 5172 hits.
-
Zero adjustment of an earth tester
https://www.hioki.com/us-en/support/faq/detail/id_314
My FT6031 displays "0Ω ADJ". Can I measure in this condition, or should I execute the zero adjustment?
-
LED lighting measurement using a lux meter
https://www.hioki.com/us-en/support/faq/detail/id_312
Can the FT3424 measure LED lighting?
-
ON/OFF of continuous measurement on the infrared temperature meter
https://www.hioki.com/us-en/support/faq/detail/id_307
The display on the FT3700 is not turning off. How do I cancel continuous measurment on the product?
-
Negative power display on the clamp on power meter
https://www.hioki.com/us-en/support/faq/detail/id_304
I got a negative (-) power value on my clamp on power meter.
What does it mean? -
Difference among MAX, MIN and AVG values in the power logger's time series graph
https://www.hioki.com/us-en/support/faq/detail/id_303
The time series data of the PW3360 has MAX, MIN, and AVG values for every interval.
How are they calculated? -
Comparing data before and after installing a power factor correction capacitor using the SF1001 software
https://www.hioki.com/us-en/support/faq/detail/id_302
I recorded power consumption data using the PW3360 before and after installing a power factor correction capacitor.
I would like to display both in one graph to compare the improvement on the SF1001. Is that possible? -
Power outage during logging (PW3360)
https://www.hioki.com/us-en/support/faq/detail/id_301
There was power outage while I was logging with the PW3360.
The power supply is already recovered, but what happens to the recorded data? -
Negative power factor value on a power meter
https://www.hioki.com/us-en/support/faq/detail/id_300
My power meter displays a negative power factor value. Why is the value negative?
-
Clamp on meters that use AC flexible sensors
https://www.hioki.com/us-en/support/faq/detail/id_299
Can I use an AC flexible sensor with the 3280-10?
-
Difference of average values between two clamp on meters
https://www.hioki.com/us-en/support/faq/detail/id_297
I got different average values between the 3285 and CM4374.
-
Impedance measurement method of coaxial cables
https://www.hioki.com/us-en/support/faq/detail/id_296
How to measure the impedance of coaxial cables using an LCR meter
-
Cannot measure current
https://www.hioki.com/us-en/support/faq/detail/id_294
The 3288 does not show the current value.
The current should be about 0.2A AC. -
The resistance value is decreasing
https://www.hioki.com/us-en/support/faq/detail/id_292
I'm measuring fuse resistance using the RM3544A.
However, the resistance value decreases gradually.
What is the cause? -
DMM for inverter output voltage measurement
https://www.hioki.com/us-en/support/faq/detail/id_289
Which DMM do you recommend to measure inverter output?
-
Communication command to use the DT4900-01
https://www.hioki.com/us-en/support/faq/detail/id_288
What are the communication commands to control the DT series using the DT4900-01?
-
DT series selection guide
https://www.hioki.com/us-en/support/faq/detail/id_287
There are many models in the DT series.
Is there any selection guide to understand the difference? -
Zero adjustment procedures of the DT4200 series
https://www.hioki.com/us-en/support/faq/detail/id_285
Please advise how to make zero adjustment of resistance measurement on the DT4281.
-
Clamp meter to measure output of secondary side inverters
https://www.hioki.com/us-en/support/faq/detail/id_284
Which clamp meters are recommended to measure the output of the secondary side inverters?
-
Measuring a DC signal with ripple
https://www.hioki.com/us-en/support/faq/detail/id_283
Which function should be used to measure a DC signal with ripple?
-
Logging interval of the CM4372
https://www.hioki.com/us-en/support/faq/detail/id_282
I want to log the current measured by the CM4372 on my smartphone.
What is the fastest logging interval?