ANALOG UNIT 8966

Max. 20 MS/s, isolated input

Key Features

  • High 12-bit A/D resolution
  • Isolated 2 channel input
  • Max. rated voltage to ground: 300 V AC, DC
  • Reliably capture instantaneous waveforms using high speed 20 MS/s sampling and A/D converter

Model No. (Order Code)

8966 For MR6000, MR8847A, MR8827, and similar products
Note: This module must be used with the Memory HiCorder. Input cords are not included. Please purchase them separately.

List of Available Memory HiCorders

Please refer to the table here for the types of input units that can be used for each Memory HiCorder.

List of Available Memory HiCorders

Basic specifications

Accuracy guaranteed: 1 year
Measurement functions Number of channels: 2, for voltage measurement
Input connectors Isolated BNC connector (input impedance 1 MΩ, input capacitance 30 pF),
Max. rated voltage to earth: 300 V AC, DC (with input isolated from the unit, the maximum voltage that can be applied between input channel and chassis and between input channels without damage)
Measurement range 5 mV to 20 V/div, 12 ranges, full scale: 20 div, (AC voltage for possible measurement/display using the memory function: 280 V rms)
Low-pass filter: 5/50/500 Hz, 5 k/50 k/500 kHz
Measurement resolution 1/100 of measurement range (using 12-bit A/D conversion and when installed in the 8847)
Highest sampling rate 20 MS/s (simultaneous sampling across 2 channels)
Measurement accuracy ±0.5 % of full scale (with filter 5 Hz, zero position accuracy included)
Frequency characteristics DC to 5 MHz -3 dB, with AC coupling: 7 Hz to 5 MHz -3dB
Input coupling AC/DC/GND
Max. allowable input 400 V DC (the maximum voltage that can be applied across input pins without damage)
Dimensions and mass 106 mm (4.17 in) W × 19.8 mm (0.78 in) H × 196.5 mm (7.74 in) D, 250 g (8.8 oz)
Included accessories None

Voltage measurement Type A (4)

* Input voltage is limited to the specifications of the input modules in use

* Max. rated voltage to earth is limited to the specifications of the input modules in use

Voltage measurement Type B (1)

* Input voltage is limited to the specifications of the input modules in use

* Max. rated voltage to earth is limited to the specifications of the input modules in use

Voltage measurement Type C (2)

* Input voltage is limited to the specifications of the input modules in use

* Max. rated voltage to earth is limited to the specifications of the input modules in use

Voltage measurement Type D (2)

* Max. rated voltage to earth is limited to the specifications of the input modules in use

* For a list of compatible Memory HiCorders, please see the product catalog