MEMORY HiCORDER 8860, 8861

High-speed 16- or 32-channel Memory Recorders Offer Data Acquisition, Oscilloscope and Data Logger Functionality to Record Waveforms in Any Situation

Hioki Memory HiCorders are high-speed waveform monitoring and recording devices that can simultaneously measure multiple physical phenomena such as voltage, current, temperature, vibration, weight, acceleration and rotation due to complete isolation between channels and from each channel to the ground. More than just a digital oscilloscope, the 8860-50 and 8861-50 memory recorders accommodate plug-and-play input modules to meet applications such as monitoring commercial power supplies, fault analysis of electrical equipment, evaluating electric vehicle chargers, and analyzing conveyor belt speeds.

Key Features

  • Built-in 80GB hard drive (no PC card slot)
  • A faster CPU greatly enhances instrument operability and response.
  • Multi-channel logging on up to 64 or 128 channels (Use with the 8958)
  • 20 MS/s high-speed sampling (Use with the 8956)
  • Various interfaces built-in: LAN/USB/Hard disk drive
  • Supports the new high-voltage input module for measuring high voltage directly

Model No. (Order Code)

8860-50 Discontinued, Main unit only, input modules up to 4 units
8860-51 Discontinued, PC card slot less, built in HD unit
8861-50 Discontinued, Main unit only, input modules up to 8 units
8861-51 Discontinued, PC card slot less, built in HD unit
Note: The 8860-51 and 8861-51 cannot operate alone. You must install one or more optional input modules in the unit.
Note: Memory boards are not built-in as a standard feature. Choose one board for Model 8860-51, and two of the same capacity for the 8861-51, for factory pre-installation.

Basic specifications

Accuracy guaranteed: 1 year
  8860-51 8861-51
Number of input units Max. 4 units Max. 8 units
Number of channels Max. 16 analog channels (Max. 64 channels when using the 8958) + standard 16 logic channels Max. 32 analog channels (Max. 128 channels when using the 8958) + standard 16 logic channels
Measurement ranges (20 div full-scale) 5 mV to 20 V/div, 12 ranges (when using the 8956), Resolution : 1/100 of range 5 mV to 20 V/div, 12 ranges (when using the 8956), Resolution : 1/100 of range
Max. allowable input DC 400V (when using the 8956) DC 400V (when using the 8956)
Frequency characteristics DC to 10 MHz (-3dB, when using the 8956) DC to 10 MHz (-3dB, when using the 8956)
Time axis at memory function 5 µs to 5 min/div, 26 ranges, sampling period : 1/100 of range, external sampling, dual timebase possible
Measurement
functions
MEM (high-speed recording) REC (real-time recording) REC & MEM (realtime recording + high-speed recording) FFT (frequency analysis) Real-time Save (records directly to storage media)
Storage memory capacity 12-bits × 32M-words/ch (1ch at 8860-51, 2ch at 8861-51) to 2M-words/ch (16ch at 8860-51, 32ch at 8861-51)
*Memory capacity can be expanded 32 times. (Optional memory board)
Removable storage USB 2.0 memory ×3, Hard disk drive (80 GB, built in the main unit) ×1 (No PC card slot)
Recording paper [Built in optional printer unit] A4: 216 mm (8.50 in) × 30 m (98.43 ft), or A6: 112 mm (4.41 in) × 18 m (59.06 ft) selectable, thermal paper roll, Recording speed : Max. 25 mm (0.98 in)/sec
Display 10.4-inch SVGA-TFT color LCD (800 × 600 dots)
External interfaces USB 2.0, LAN, Monitor output (15 pin D-sub output), *GP-IB is Not Available
Power supply 100 to 240 V AC (50/60 Hz) (220 VA max. printer not used)
12 V DC (use the DC power unit 9684 : option, factory installation only)
100 to 240 V AC (50/60 Hz) (280 VA max. printer not used)
12 V DC (use the DC power unit 9684 : option, factory installation only)
Dimensions and mass 330 mm (12.99 in) W × 250 mm (9.84 in) H × 184.5 mm (7.26 in) D, 8 kg (282.2 oz) (printer not installed) 330 mm (12.99 in) W × 250 mm (9.84 in) H × 284.5 mm (11.20 in) D, 10.5 kg (370.4 oz) (printer not installed)
Included accessories Quick Start Manual × 1, Input Module Guide × 1, Instruction Manual × 1, Analysis and Communication Supplement × 1, Application Disk (WaveViewer Wv, communication commands table) × 1, Power cord × 1, Input cord label × 1, Ferrite clamp (for LAN cable) × 1

LabVIEW and MATLAB support

Compatible models LabVIEW MATLAB script
8860-50 Available Available
8861-50 Available Available

Printer options (2)

Factory-installed options (A) (1)

*Must specify when ordering

Note: Choose one memory board for Model 8860-51, and two of the same capacity for the 8861-51, 80-GB HD drive is factory pre-installation.

Factory options (B) (0)

*Must specify when ordering

* Only one of either the DC Power Unit 9684 or Probe Power Unit 9687 can be installed at any one time. Please contact your Hioki representative if concurrent installation is required.

Factory options (C) (0)

*Must specify when ordering

* Either the DC power unit 9684 or the probe power unit 9687 may be used. If you want to use both at the same time, consult us.

Input modules (1)

*Input cords are not included. Please purchase them separately. Install by inserting into the main unit. Can be replaced by user.

Input cable (A) (4)

*Voltage is limited to the specifications of the input modules in use

Input cable (B) (3)

*Voltage is limited to the specifications of the input modules in use

Input cord (C) (1)

Input cable (D) (2)

Custom cable (0)

*For P9000. Inquire with your Hioki distributor.

(1) Bus powered USB cable
(2) USB(A)- Micro B cable
(3) 3-prong cable

Input cable (E) (3)

*Voltage to ground is within this product's specifications.

*For powering the 9322, AC Adapter 9418-15 or the 9687/9248 are required separately.

Non-contact Voltage measuring (0)

Other options for Input (3)

Temperature sensor (0)

*For reference only. Please purchase locally.

Thermocouple

Up to 1000 A (High precision) (0)

Power supply (1)

Current sensors for the F/V Unit 8940 (4)

*To connect the current sensor via the conversion cable for the F/V Unit 8940, or using with the Power supply unit 9555-10.

*The 3274/3275/3276 cannot be used for the F/V Unit 8940.

100 A to 2000 A (Medium speed) B (0)

Leak Current (2)

*For commercial power lines, 50/60 Hz

Up to 2000 A (Curent meter) (0)

*Clamp sensor sold separately

PC Software (2)

* The 9335 supports 8860-50/8860, 8861-50/8861 series MEM, REC and REC&MEM data recorded using single-axis sampling only.

Cases (0)