MEMORY HiCORDER MR8847-01 MR8847-02 MR8847-03 8847

V3.25 Nov 07, 2019

If you are unable to download software, please check the following:
  • Please register a my HIOKI account and then use it to log in to the my HIOKI service.
  • Product firmware (product upgrades) and computer application software can only be downloaded for products you have registered on the my HIOKI service.
Firmware (8847V325.zip)
Procedure on how to update the firmware (8847VUPE.pdf)

・All software provided the best version currently available.
・If the problems or errors during this download and install lead to malfunction, please contact your dealer or Hioki representative.
・The ownership, intellectual right and all other associated rights relating to the firmware provided here belong to Hioki E.E. Corporation.


If you have read and understand the information above and wish to proceed then please download the designated files.
As for version upgrade procedure, please download ”Procedure on how to update the firmware” which describes the preparation and procedure for upgrading firmware after downloading the files.
The upgradefile is common to MR8847-01, MR8847-02, MR8847-03 and 8847.

Precaution when updating firmware:
・To conduct the version upgrade, USB memory stick is required.
・During the version upgrade process, don’t turn off the power to the MR8847-01, MR8847-02, MR8847-03 and 8847 or don’t remove the USB memory stick from the slot.

Firmware for the Model MR8847-01, MR8847-02, MR8847-03 and 8847

The current newest firmware versions are shown below. A version update is highly recommended if you are running older firmware.

・Firmware Version: V3.25

How to check the version number

The version numbers of firmware can be checked by viewing the bottom left portion of the startup window when the 8847 is turned on.
When selecting ”System Information” from Self-Test checks on System screen, the currently running firmware version numbers will appear at the bottom.

Version Upgrade History

V3.25  (November 2019)  Newest Version
Resolved bugs
・Fixed a bug when AAF is turned on and the sampling speed is set to a speed higher than 1ms/div the accuracy may not be satisfied.
Improvement
・Increased mouse models.
・The setting state of the save channel when saving the waveform file is retained.
   
V3.24  (August 2019)
Added functions
・CT6865 has been added to the sensor that can be used in the 8971 current unit.
・The sensor types CT6700, CT6701, CT6710 and CT6711 have been added to the "clamp" of scaling.
Improvement
・When the measurement is interrupted while waiting for the trigger, the numerical result is also preserved when the waveform data remains.
Resolved bugs
・Fixed a bug when the measurement of maximum, minimum and peak value is set by numerical calculation, the calculation result displayed when stopping measurement is incorrect may be incorrect.

V3.23 (January 2018)
Resolved bugs
・Fixed a bug that the value obtained using the communication command ": MEMory: GETReal;: VREAl?" for the 12-bit measurement unit is slightly larger than the correct value.
・Other minor bugs were resolved.
Improvement
・Variable setting is automatically changed after changing the scaling setting value of the strain unit.
・The automatic balancing method of the strain unit was improved and the accuracy was improved.

V3.22 (October 2016)
Resolved bugs
・After the display check or key check in the self-check screen, or after displaying the once system information, it is displayed without the mounting unit again to display the system information.

V3.21 (August 2016)
Resolved bugs
・When the auto-saving to PC connected via LAN is stoppded、during measurement by the recorder function or roll mode,Unreadable file is created.

V3.20 (February 2016)
Added functions
・HIGH VOLTAGE UNIT is available.
Resolved bugs
・Fixed a bug that High/Low calculation is wrong value when the number of data is small.
・Fixed a bug that STOP input of the external terminal does not work, when the setting of  the external control terminal was to START & STOP.
・Other minor bugs were resolved.

V3.11 (May 2015)
Resolved bugs
・Fixed an issue where the communication command ”:SYSTem:SaveKind” can not change the save type. Only 8847.
・Fixed the communication command function and the FTP client function.
・When the main operation in the HMR Terminal, if you change the range during the measurement in the time-axis range is 100ms / div following slow time axis, Fixed an issue in which the waveform of the HMR Terminal will no longer be updated.
Improvement
・Fixed save kind of when you switch the function.
・Fixed the range setting display of waveform screen.
・Fixed remote control in 9333.

V3.10 (December 2014)
Added functions
Corresponding to the HMR Terminal Ver.2.
Improvement
On Internet Explorer (Windows7 or later), when you download the waveform data by pressing the [To MS Excel], the file extension was set to be CSV.
Resolved bugs
1. When performing a waveform evaluation from the communication command, executing the evaluation immediately after the waveform display is ON, resulting in running the decision on the previous image to redraw the waveform.
2. Communication command ”: FDISK: CHDIR” using, it is not possible to move to the directory in the root directory.
3.Other minor bugs were resolved.

V3.07 (March 2014)
Added functions
Communication function with 9333 LAN communicator.

V3.06 (December 2013)
Resolved bugs
1.When the timebase is set to 1min/DIV or slower, if the display of a time value is set to the [date] and measurement is started, the date displayed on the lower part of a waveform screen will be garbled, or when the worst, a system error will be started and it will hang-up.
2.If each setup of variable, scaling, and auto scale is set to ON when setting up a strain unit, even if it changes rated capacity, the upper and lower limit value of a variable will not be changed automatically.
 
V3.05 (November 2013)
Improvement
The time display of a waveform screen in case there is no waveform data is displayed with the value of the present time-axis setup.
Resolved bugs
1.When the current clamps of the time of saving a setting file and the present differed, and the setting file was read, the fault in which the measured value of a current unit makes a mistake was corrected.
2.The fault the kind of temperature sensor is not saved at a setting file was corrected.
3.Other minor bugs were resolved.
 
V3.04 (June 2013)
Resolved bugs
1.The measurement processing after power activation was resolved.
2.Other minor bugs were resolved.

V3.03 (October 2011)
Added functions
1.Added [Hex] to [Format] item.
Resolved bugs
1.When you change the [Format] setting of X-Y recorder function, its printing format cannot be changed.(Applies only to units with firmware version 3.02)
2.Other minor bugs were resolved.

V3.02 (June 2011)
Added functions
1.The Roll mode function for X-Y waveform.
Resolved bugs
1.Problems with auto-saving data or auto-printing data while using the memory division feature.
2.Other minor bugs were resolved.

V2.07 (February 2011)
Added functions
1.Chinese display screen

V2.06 (December 2010)
Resolved bugs
1.Fixed an error in regard to end code of BMP compressed file.
2.Other minor bugs were resolved.

V2.05 (June 2010)
Resolved bugs
1.When the speed of LAN communication is in 10BASE(or the speed of LAN communication is low), during FTP file transfer, communication may stop and some of the transferred data may be corrupted (MAC address and measurement data).

V2.04 (March 2010)
Added functions
1.The batch copy function to copy Unit related settings.
2.Now you can select from two file sizes to save Waveform image data.
Resolved bugs
1.When displaying the ”XYSingle” or ”XYQuad” format for the Memory function, if you printed or saved the waveform data after stopping measurement, there were cases when a non-existent data extra was included.
2.Other minor bugs were resolved.

V2.03 (February 2010)
Resolved bugs
1.When copying the scaling setting values to another channel on the scaling screen, if the variable function is enabled on the copy destination channel, the upper and lower limits can not be set correctly, so that the size of the waveform is not displayed correctly.
2.Other minor bugs were resolved.

V2.02 (January 2010)
Resolved bugs
1.When performing a time difference calculation or a phase contrast calculation, if the channel of the phenomenon A was set by the waveform calculation number and the channel of the phenomenon B was set as analog channel, the level value for the phenomenon B was automatically replaced by the level value for the phenomenon A.
2.Other minor bugs were resolved.

V2.01 (August 2009)
Added functions
1.FFT Function
2.Memory Division Function
3.Waveform Calculation Function
4.8970/8971units are now applicable
5.Some numerical calculations were added: Time difference calculation, Phase contrast calculation, High/Low level calculation
6.Trigger search function
Resolved bugs
1.When the units configuration of the loaded file was different from the currently installed units configuration, the setting file was found not to be loaded correctly.
2.When performing Pen up/down operation 1000 times or more and then printing waveforms with line interpolation function, the portion that should not be interpolated was found to be interpolated.
3.Other minor bugs were resolved.

V1.06 (February 2009)
Improvement
1.The multiple maker’s internal memory chips are now applicable.
*This version upgrade will not affect the performance of your 8847.

V1.05 (December 2008)
Resolved bug
1.When the waveforms of 9 channels or more was printed manually at a print speed set to ”Fast”, the printing was found to stop halfway.

V1.04 (December 2008)
Resolved bug
1.When turning on the power, checksome error for the unit not being installed was found to appear rarely.

V1.03 (November 2008)
Resolved bug
1.When a trigger event occurred by Standard logic signal if the waveform changed faster than the sampling interval, the waveform change at the point of triggering was found not to be displayed on the screen.
2.Other minor bugs were resolved.

V1.02 (October 2008)
Added function
1.Korean display screen
Resolved bugs
1.When the units configuration of the loaded file was different from the currently installed units configuration, the waveform data was found not to be displayed correctly on the screen.
2.Other minor bugs were resolved.