CommandDataExplanationL
C
R
C
O
N
T
I
N
U
O
U
S

Common Commands

*CLSClearing the status byte register and related queues (except the output queue)
*ESE<Mask value>Reading and writing the standard event status enable register (SESER)
*ESE?
*ESR?Reading and clearing the standard event status register (SESR)
*IDN?Querying the instrument ID (Identification Code)
*OPCSetting OPC of SESR after all of the actions being executed are finished
*OPC?Sending response of ASCII 1 after all of the actions being executed are finished
*RSTInitializing the instrument
*SRE<Mask value>Writing and reading the service request enable register (SRER)
*SRE?
*STB?Reading the Status Byte Register
*TRGRequesting a Sample
*TST?Executing self tests and querying results
*WAIExecuting following command after command processing is finished

Event Registers

:ESE0<Mask value>Writing and reading event status enable register 0
:ESE0?
:ESE1<Mask value>Writing and reading event status enable register 1
:ESE1?
:ESE2<Mask value>Writing and reading event status enable register 2
:ESE2?
:ESE3<Mask value>Writing and reading event status enable register 3
:ESE3?
:ESR0?Reading event status register 0
:ESR1?Reading event status register 1
:ESR2?Reading event status register 2
:ESR3?Reading event status register 3

Measurement Mode

:MODE<LCR/CONTinuous>Setting and querying measurement mode
:MODE?

Measurement Frequency

:FREQuency<Frequency>Setting and querying the Measurement Frequency
:FREQuency?

Measurement Range

:RANGe<Range No.>Setting and querying the measurement range
:RANGe?
:RANGe:AUTO<ON/OFF>Automatically setting and querying the measurement range
:RANGe:AUTO?
:RANGe:AUTO:LIMit<RST/lower limit range>,<upper limit range>Setting and querying the AUTO range limit function
:RANGe:AUTO:LIMit?
:RANGe:JSYNc<ON/OFF>Setting and querying the JUDGE synchronization setting
:RANGe:JSYNc?
:RANGe:LOWZ<ON/OFF>Setting and querying low Z high accuracy mode
:RANGe:LOWZ?
:RANGe:SYNC<ON/OFF>Setting and querying the range synchronization function
:RANGe:SYNC?
:RANGe:SYNC:AVERaging<ALL/Range No.>,<OFF/number of averaging times>Setting and querying the number of measurement averaging time for the range synchronization function
:RANGe:SYNC:AVERaging?<Range No.>
:RANGe:SYNC:SPEEd<ALL/Range No.>,<FAST/MEDium/SLOW/SLOW2>Setting and querying the measurement speed for the range synchronization function
:RANGe:SYNC:SPEEd?<Range No.>
:RANGe:SYNC:TRIGger:DELay<ALL/Range No.>,<Trigger delay time>Setting and querying the trigger delay time for the range synchronization function
:RANGe:SYNC:TRIGger:DELay?<Range No.>
:RANGe:SYNC:SSOurce<ALL/Range No.>,<ON/OFF>Setting and querying the trigger synchronous output function for the range synchronization function
:RANGe:SYNC:SSOurce?<Range No.>
:RANGe:SYNC:SSOurce:WAIT<ALL/Range No.>,<Wait time>Setting and querying the wait time of the trigger synchronous output function for the range synchronization function
:RANGe:SYNC:SSOurce:WAIT?<Range No.>

Measurement Signal Level

:LEVel<V/CV/CC>Setting and querying the measurement signal level
:LEVel?

Constant current level

:LEVel:CCURRent<Constant current level>Setting and querying the constant current level value
:LEVel:CCURRent?

Constant voltage level

:LEVel:CVOLTage<Constant voltage level>Setting and querying the constant voltage level
:LEVel:CVOLTage?

Open-circuit voltage level

:LEVel:VOLTage<Open-circuit voltage level>Setting and querying the open-circuit voltage level
:LEVel:VOLTage?

Measurement Speed

:SPEEd<FAST/MEDium/SLOW/SLOW2>Setting and querying the measurement speed
:SPEEd?

Limit Function of Measurement Signal Level

:LIMiter<ON/OFF>Setting and querying the limit function
:LIMiter?
:LIMiter:CURRent<Current limit value>Setting and querying the current limit value
:LIMiter:CURRent?
:LIMiter:VOLTage<Voltage limit value>Setting and querying the voltage limit value
:LIMiter:VOLTage?

Average Function

:AVERaging<OFF/ number of averaging times>Setting and querying measurement averaging
:AVERaging?

DC bias function

:DCBias<ON/OFF>Setting and querying ON/ OFF of DC bias function
:DCBias?
:DCBias:LEVel<DC bias level>Setting and querying the DC bias level
:DCBias:LEVel?

Trigger

:TRIGger<INTernal/EXTernal>Setting and querying the trigger mode
:TRIGger?
:TRIGger:DELay<Trigger delay time>Setting and querying the trigger delay time
:TRIGger:DELay?

Trigger Synchronous Output Function

:SSOurce<ON/OFF>Setting and querying the trigger synchronous output function
:SSOurce?
:SSOurce:WAIT<Wait time>Setting and querying the wait time of trigger synchronous output
:SSOurce:WAIT?

DC Resistance Measurement Function

:DCResistance:RANGe<Range No.>Setting and querying the measurement range for when DC resistance measurement
:DCResistance:RANGe?
:DCResistance:RANGe:AUTO<ON/OFF>Automatically setting and querying the measurement range for when DC resistance measurement
:DCResistance:RANGe:AUTO?
:DCResistance:RANGe:AUTO:LIMit<RST/lower limit range>,<upper limit range>Setting and querying the AUTO range limit function during DC resistance measurement
:DCResistance:RANGe:AUTO:LIMit?
:DCResistance:RANGe:LOWZ<ON/OFF>Setting and querying low Z high accuracy mode for when DC resistance measurement
:DCResistance:RANGe:LOWZ?
:DCResistance:RANGe:JSYNc<ON/OFF>Setting and querying the JUDGE synchronization setting during DC resistance measurement
:DCResistance:RANGe:JSYNc?
:DCResistance:RANGe:SYNC:AVERaging<ALL/Range No.>,<OFF/number of averaging times>Setting and querying the number of measurement averaging time for the range synchronization function during DC resistance measurement
:DCResistance:RANGe:SYNC:AVERaging?<Range No.>
:DCResistance:RANGe:SYNC:SPEEd<ALL/Range No.>,<FAST/MEDium/SLOW/SLOW2>Setting and querying the measurement speed for the range synchronization function during DC resistance measurement
:DCResistance:RANGe:SYNC:SPEEd?<Range No.>
:DCResistance:SPEEd<FAST/MEDium/SLOW/SLOW2>Setting and querying the measurement speed for when DC resistance measurement
:DCResistance:SPEEd?
:DCResistance:AVERaging<OFF/ number of averaging times>Setting and querying averaging for when DC resistance measurement
:DCResistance:AVERaging?
:DCResistance:ADJust<ON/OFF>Setting and querying the DC offset for when DC resistance measurement
:DCResistance:ADJust?
:DCResistance:ADJust:DEMandAcquiring DC offset for when DC resistance measurement
:DCResistance:ADJDelay<Adjustment Delay time>Setting and querying the adjustment delay time during DC resistance measurement
:DCResistance:ADJDelay?
:DCResistance:DCDelay<DC Delay time>Setting and querying the DC delay time during DC resistance measurement
:DCResistance:DCDelay?
:DCResistance:LFRequency<Line Frequency>Setting and querying the line frequency during DC resistance measurement
:DCResistance:LFRequency?

Judgment Function

:JUDGmentSetting and querying the judgment function
:JUDGment?

Comparator Function

:COMParator<OFF/ON>Setting and querying ON/ OFF of comparator function
:COMParator?
:COMParator:FLIMit:ABSolute<OFF/ lower value>,<OFF/ upper value>Setting and querying the upper and lower limit values of the first parameter of the comparator function (absolute value mode)
:COMParator:FLIMit:ABSolute?
:COMParator:FLIMit:DEViation<Reference value>,<OFF/ Lower limit values>,<OFF/ Upper limit values>Setting and querying the reference value and the upper and lower limit values of the first parameter of the comparator function (deviation percentage (Ģ%) mode)
:COMParator:FLIMit:DEViation?
:COMParator:FLIMit:MODE<ABSolute/PERcent/DEViation>Setting and querying the judgment mode of the first parameter of the comparator function
:COMParator:FLIMit:MODE?
:COMParator:FLIMit:PERcent<Reference value>,<OFF/ Lower limit values>,<OFF/ Upper limit values>Setting and querying the reference value and the upper and lower limit values of the first parameter of the comparator function (percentage (%) mode)
:COMParator:FLIMit:PERcent?
:COMParator:SLIMit:ABSolute<OFF/ lower value>,<OFF/ upper value>Setting and querying the upper and lower limit values of the third parameter of the comparator function (absolute value mode)
:COMParator:SLIMit:ABSolute?
:COMParator:SLIMit:DEViation<Reference value>,<OFF/ Lower limit values>,<OFF/ Upper limit values>Setting and querying the reference value and the upper and lower limit values of the SUB parameter of the comparator function (deviation percentage (Ģ%) mode)
:COMParator:SLIMit:DEViation?
:COMParator:SLIMit:MODE<ABSolute/PERcent/DEViation>Setting and querying the judgment mode of the third parameter of the comparator function
:COMParator:SLIMit:MODE?
:COMParator:SLIMit:PERcent<Reference value>,<OFF/ Lower limit values>,<OFF/ Upper limit values>Setting and querying the reference value and the upper and lower limit values of the third parameter of the comparator function (percentage mode)
:COMParator:SLIMit:PERcent?

BIN Function

:BIN<OFF/ON>Setting and querying ON/ OFF of BIN function
:BIN?
:BIN:FLIMit:ABSolute<BIN number>,<OFF/ lower value>,<OFF/ upper value>Setting and querying the upper and lower limit values of the first parameter of the BIN function (absolute value mode)
:BIN:FLIMit:ABSolute?<BIN number>
:BIN:FLIMit:DEViation<BIN number>,<OFF/ lower value>,<OFF/ upper value>Setting and querying the upper and lower limit values of the first parameter of the BIN function (deviation percentage (Ģ%) mode)
:BIN:FLIMit:DEViation?<BIN number>
:BIN:FLIMit:MODE<ABSolute/PERcent/DEViation>Selecting and querying the mode of the first parameter of the BIN function
:BIN:FLIMit:MODE?
:BIN:FLIMit:PERcent<BIN number>,<OFF/ lower value>,<OFF/ upper value>Setting and querying the upper and lower limit values of the first parameter of the BIN function (percentage (%) mode)
:BIN:FLIMit:PERcent?<BIN number>
:BIN:FLIMit:REFerence<Reference value>Setting and querying the reference value of the first parameter of the BIN function (percentage (%) mode and deviation percentage (Ģ%) mode)
:BIN:FLIMit:REFerence?
:BIN:SLIMit:ABSolute<BIN number>,<OFF/ lower value>,<OFF/ upper value>Setting and querying the upper and lower limit values of the third parameter of the BIN function (absolute value mode)
:BIN:SLIMit:ABSolute?<BIN number>
:BIN:SLIMit:DEViation<BIN number>,<OFF/ lower value>,<OFF/ upper value>Setting and querying the upper and lower limit values of the third parameter of the BIN function (deviation percentage (Ģ%) mode)
:BIN:SLIMit:DEViation?<BIN number>
:BIN:SLIMit:MODE<ABSolute/PERcent/DEViation>Selecting and querying the mode of the third parameter of the BIN function
:BIN:SLIMit:MODE?
:BIN:SLIMit:PERcent<BIN number>,<OFF/ lower value>,<OFF/ upper value>Setting and querying the upper and lower limit values of the third parameter of the BIN function (percentage (%) mode)
:BIN:SLIMit:PERcent?<BIN number>
:BIN:SLIMit:REFerence<Reference value>Setting and querying the reference value of the third parameter of the BIN function (percentage (%) mode and deviation percentage (Ģ%) mode)
:BIN:SLIMit:REFerence?

Measurement Value Output

:MEASure?Querying measurement data
:MEASure:OUTPut:AUTO<ON/OFF>Setting and querying the measurement value automatic output function
:MEASure:OUTPut:AUTO?
:MEASure:VALid<Setting value>Setting and querying the response data of the measurement acquisition query
:MEASure:VALid?
:MEASure:ITEM<MR0>, <MR1>, <MR2>Setting and querying measurement parameters
:MEASure:ITEM?

Parameter Settings (# is a numerical value from 1 to 4)

:PARameter#<Z/ Y/ PHASE(phase angle)/ CS/ CP/ D/ LS/ LP/ Q/ RS/ G/ RP/ X/ B/ RDC/ S/ E/ OFF>Setting and querying the display parameters
:PARameter#?
:PARameter#:DIGit<Number of display digits>Setting and querying number of display digits
:PARameter#:DIGit?

Open / Short Compensation Range

:CORRection:LIMit:DC<ON/OFF>Open / Short compensation function on/off setting and querying during DC measurement
:CORRection:LIMit:DC?
:CORRection:LIMit:POINt<UNLimited/Compensation minimum frequency>, <UNLimited/Compensation maximum frequency>Open / Short compensation range setting and querying during AC measurement
:CORRection:LIMit:POINt?

Open-circuit Compensation Function

:CORRection:OPEN<OFF/ALL/SPOT/CANCel>Executing, cancelling, and querying the open compensation function
:CORRection:OPEN?
:CORRection:OPEN:ERRor?Querying open compensation failure flag
:CORRection:OPEN:FREQuency<Compensation No.>,<OFF/ DC/ Frequency>Setting and querying frequency for acquiring open compensation value
:CORRection:OPEN:FREQuency?<Compensation No.>
:CORRection:OPEN:RETurn<OFF/ALL/SPOT>Setting and querying the open compensation function
:CORRection:OPEN:RETurn?
:CORRection:OPEN:DATA:ALL?Open compensation value inquiry (all compensation)
:CORRection:OPEN:DATA:SPOT?<Compensation No.>Open compensation value inquiry (spot compensation)

Short Circuit Compensation Function

:CORRection:SHORt<OFF/ALL/SPOT/CANCel>Executing, cancelling, and querying the short compensation function
:CORRection:SHORt?
:CORRection:SHORt:ERRor?Querying short compensation failure flag
:CORRection:SHORt:FREQuency<Compensation No.>,<OFF/ DC/ Frequency>Setting and querying frequency for acquiring short compensation value
:CORRection:SHORt:FREQuency?<Compensation No.>
:CORRection:SHORt:RETurn<OFF/ALL/SPOT>Setting and querying the short compensation function
:CORRection:SHORt:RETurn?
:CORRection:SHORt:DATA:ALL?Short compensation value inquiry (all compensation)
:CORRection:SHORt:DATA:SPOT?<Compensation No.>Short compensation value inquiry (spot compensation)

Load Compensation Function

:CORRection:LOAD<OFF/ON>Executing and querying the load compensation function
:CORRection:LOAD?
:CORRection:LOAD:CONDition<Compensation No.>,<Frequency>,<Range No.>,<LOW Z>,<V/ CV /CC>,<Level value>,<DC bias>,<DC bias value>Setting and querying the load compensation conditions
:CORRection:LOAD:CONDition?<Compensation No.>
:CORRection:LOAD:DCResistance:CONDition<Compensation No.>,<Range No.>,<LOW Z>Setting and querying the load compensation conditions for when DC resistance measurement
:CORRection:LOAD:DCResistance:CONDition?<Compensation No.>
:CORRection:LOAD:DCResistance:REFerence<Compensation No.>,<Reference value>Setting and querying the reference value of load compensation for when DC resistance measurement
:CORRection:LOAD:DCResistance:REFerence?<Compensation No.>
:CORRection:LOAD:DATA?<Compensation No.>Load compensation value inquiry
:CORRection:LOAD:ERRor?Querying load compensation failure flag
:CORRection:LOAD:REFerence<Compensation No.>,<Mode No.>,<Reference value1>,<Reference value2>Setting and querying the reference values of load compensation
:CORRection:LOAD:REFerence?<Compensation No.>
:CORRection:LOAD:RESet<Compensation No.>Resetting the load compensation conditions
:CORRection:LOAD:RETurn<OFF/ON>Setting and querying the load compensation function
:CORRection:LOAD:RETurn?

Cable length compensation function

:CORRection:CABLe<Cable length>Setting and querying the cable length compensation function
:CORRection:CABLe?

Scaling Function

:CORRection:SCALe<OFF/ON>Setting and querying the scaling compensation function
:CORRection:SCALe?
:CORRection:SCALe:DATA<Scaling No.>,<Compensation value A>,<Compensation value B>Setting and querying the scaling compensation value
:CORRection:SCALe:DATA?<Scaling No.>

Continuous measurement settings

:CONTinuous:DRAW<REAL/AFTer>Setting and querying the screen display timing
:CONTinuous:DRAW?
:CONTinuous:EXECution<Panel No.>, <ON/OFF>Setting and querying the continuous measurement target
:CONTinuous:EXECution?<Panel No.>
:CONTinuous:COUNt?Panel count targeted for measurement in continuous measurement mode inquiry

Measurement Value Output

:MEASure?<No data/ ALL>Querying measurement data
:MEASure:CONTinuous:COMParator?Querying the overall judgment result when continuous measurement

Waveform Averaging Function

:WAVE<ON/OFF>Setting and querying the waveform averaging function
:WAVE?
:WAVE:NUM<Frequency No.>,<number of measurement waveforms>Setting and querying the number of measurement waveforms for the waveform averaging function
:WAVE:NUM?<Frequency No.>
:WAVE:RESet<FAST/MEDium/SLOW/SLOW2>Resets the number of measurement waveforms for the waveform averaging function to that of each measurement speed.

Contact Check Function

:CCHeck:VERify<OFF/BEFore/AFTer/BOTH>Setting and querying the contact check function
:CCHeck:VERify?
:CCHeck:SENSitivity<Settable range>Setting and querying the settable range for the contact check function
:CCHeck:SENSitivity?
:CCHeck:DELay<Delay time>Setting and querying the contact check delay time
:CCHeck:DELay?

HIGH- Z reject function

:HIZ<ON/OFF>Setting and querying the Hi Z reject function
:HIZ?
:HIZ:LIMit<Limit value>Setting and querying the limit value of the Hi Z reject function
:HIZ:LIMit?

Measurement Value Memory Function

:MEMory?<No data/ ALL>Querying measurement values saved to memory with the measurement value memory function
:MEMory:CLEarClearing memory of measurement value memory function
:MEMory:CONTrol<ON/IN/OFF>Setting and querying the measurement value memory function
:MEMory:CONTrol?
:MEMory:COUNt?Querying the number of measurement values saved to memory with the memory function
:MEMory:POINts<Memory size>Setting and querying the measurement value memory size
:MEMory:POINts?
:MEMory:SAVESaving of measured value memory

Display Function

:DISPlay<ON/OFF>Setting and querying LCD display
:DISPlay?

Zoom Function

:ZOOM<ON/OFF>Setting and querying the zoom function
:ZOOM?

BCD Output Function

:IO:BCD<OFF/ON>Setting and querying ON/ OFF of BCD output function
:IO:BCD?
:IO:BCD:DECimal<Parameter No.>, <Decimal point>Setting and querying decimal point of BCD output function
:IO:BCD:DECimal?<Parameter No.>

Key Lock

:KEYLockExecuting and querying the key lock
:KEYLock?
:KEYLock:PASScode<Passcode/ none>Setting the key lock passcode
:KEYLock:UNLock<Passcode/ none>Disabling the key lock

Beep Tone

:BEEPer:JUDGment<OFF/IN/NG>Setting and querying beep sound for the judgment results of measurement values
:BEEPer:JUDGment?
:BEEPer:KEY<ON/OFF>Setting and querying beep sound for key input
:BEEPer:KEY?
:BEEPer:TONE<A/B/C/D>Setting and querying the beep tone type
:BEEPer:TONE?

Calculation Setting of Conductivity/Permittivity

:CALCulate:PARameter<CS/ CP>Setting and querying the calculation parameters of conductivity/permittivity
:CALCulate:PARameter?
:CALCulate:LENGth<Length of conductor>Setting and querying the conductor length during calculation of conductivity/permittivity
:CALCulate:LENGth?
:CALCulate:AREA<Cross-sectional area of conductor>Setting and querying the cross-sectional area of the conductor during calculation of conductivity/permittivity
:CALCulate:AREA?

Calculation Setting of Conductivity

:SIGMa<Length of conductor>, <Cross-sectional area of conductor>Setting and querying the length and cross-sectional area of the conductor during calculation of conductivity
:SIGMa?

EXT I/O Output

:IO:EOM:MODE<HOLD/PULSe>INDEX and EMO output method setting and inquiry
:IO:EOM:MODE?
:IO:EOM:PULSe<Pulse width>Pulse width for which to keep EOM low (on) setting and inquiry
:IO:EOM:PULSe?
:IO:OUTPut:DELay<I/O delay time>Setting and querying the delay time between judgment result output and EOM output
:IO:OUTPut:DELay?
:IO:RESult:RESet<ON/OFF>Setting and querying output of the judgment result signal line
:IO:RESult:RESet?
:IO:TRIGger:EDGe<DOWN/UP>Setting and querying the trigger edge
:IO:TRIGger:EDGe?
:IO:TRIGger:ENABle<ON/OFF>Setting and querying permit/prohibit of trigger input during measurement
:IO:TRIGger:ENABle?

Panel Save Function

:SAVE<Panel No.>,<Panel name>Executing and querying the panel save function
:SAVE?<Panel name>
:SAVE:CLEar<ALL/ Panel No.>Clearing data saved for a panel
:SAVE:NAME?<Panel No.>Querying a panel name
:SAVE:REName<Panel No.>,<Panel name>Changing a panel name
:SAVE:TYPE<ALL/HARDware/ADJust>Setting and querying the save type
:SAVE:TYPE?
:SAVE:MODE?<Panel No.>Querying the save type

Panel Load Function

:LOAD<Panel No.>Executing panel load

Message Terminator

:TRANsmit:TERMinator<Terminator number>Setting and querying the terminator of the response message
:TRANsmit:TERMinator?

RS-232C Communication Handshake

:HANDshake<OFF/HARDware/X/BOTH>Setting and querying the RS-232C Communication Handshake
:HANDshake?

Data transfer format

:FORMat:DATA<ASCii/REAL>Setting and querying the data transfer format
:FORMat:DATA?
:FORMat:LONG<ON/OFF>Setting and querying long format for when data transfer
:FORMat:LONG?

Header

:HEADer<ON/OFF>Setting and querying existence of header in response message
:HEADer?

System Settings

:SYSTem:DATE<Year>,<Month>,<Day>Setting and querying the date
:SYSTem:DATE?
:SYSTem:MACAddress?Querying the MAC address
:SYSTem:SERIAlno?Querying the serial number
:SYSTem:TIME<Hour>,<Minute>,<Second>Setting and querying the time
:SYSTem:TIME?
:SYSTem:USBId?Returns the USB ID.

Initialize Device

:PRESetInitializing the instrument

File storage function

:FILE:DATE<ON/OFF>Setting and querying the date and time for when saving text
:FILE:DATE?
:FILE:DELIMiter<COMma/TAB/SEMIcolon/SPACE>Setting and querying the delimiter for when saving text
:FILE:DELIMiter?
:FILE:FOLDer<Folder name>Setting and querying the save folder
:FILE:FOLDer?
:FILE:INFOrmation?Querying USB flash drive information
:FILE:MODE<AUTO/MANUAL>Setting and querying the mode of the save folder
:FILE:MODE?
:FILE:PANel:SAVE<Panel name>Execution of panel save to USB memory
:FILE:PANel:LOAD<Panel name>Execution of panel load from USB memory
:FILE:PANel:ALLSave<Specified save folder name>Execution of all save to USB memory
:FILE:PANel:ALLLoad<Specified save folder name>Execution of all load from USB memory
:FILE:PARAmeter<ON/OFF>Setting and querying the measurement parameter setting for when saving text
:FILE:PARAmeter?
:FILE:QUOTe<OFF/DOUBle/SINGle>Setting and querying the quotation mark setting for when saving text
:FILE:QUOTe?
:FILE:SAVEExecuting file saving
:FILE:SET<ON/OFF>Setting and querying the measurement condition setting for when saving text
:FILE:SET?
:FILE:TYPE:TEXT<OFF/ON>Text save settings and inquiry
:FILE:TYPE:TEXT?
:FILE:TYPE:BMP<OFF/COLor/MONochrome>BMP save settings and inquiry
:FILE:TYPE:BMP?

Monitor Function

:MONItor?Querying the voltage/current monitor value

Screen storage function