SW1001 Application Software

SW1001 Application Software

V1.02  Mar 19, 2020

The copyright to the executable program file and associated documents is owned by HIOKI E.E. CORPORATION.
This utility may not be bundled with software or other publications which are sold for profit without the express written permission of the copyright owner.
Further, this product may not be modified without the express written permission of the copyright owner.


HIOKI disclaims any and all responsibility for any consequences arising out of use of this software.


  • application(setup_SW1001Appli_V1.02.0.0.exe)

    DOWNLOAD

Version upgrade should be conducted by a qualified technician familiar with the functions and operations.
If you are uncertain as to how to proceed, please contact your local HIOKI distributor for assistance.

Summary

Easily conduct multi-channel battery measurements without additional PC programming using this free application.

Operating Environment

OS: Windows 7(32bit / 64bit), Windows 8(32bit / 64bit), Windows 8.1(32bit / 64bit), Windows 10(32bit / 64bit)
Display resolution: 1024 x 768 pixel (XGA) or more
HDD: 1GB or more free space (for storing recorded data)

Specifications

・Measurement function:
OCV Measurement function, Logging function, Cole-Cole plot measurement function




・Supported measurement instruments:
Via SW9001 (2wire / 4wire)
Battery Tester BT3562, BT3563, 3561
Precision DC Voltmeter DM7275, DM7276
Resistance Meter RM3544, RM3545
DMM 3237, 3238


Via SW9002 (4-terminal pair / etc.)

Battery Impedance Meter BT4560
Chemical Impedance Analyzer IM3590
LCR Meter IM3536, IM3570, IM3523, IM3533
Resistance Meter RM3542, RM3542A, RM3543


・Other functions


Save measurement data in CSV file format.
Create save files for each channel.
RS-232C/USB/LAN supported (matching the communication function of the connected device).
Support communication command forwarding function.

Installation procedure

1. Click [Download] and download the file.
2. Double click the downloaded file and follow the instructions appearing on the screen.

Version Update History

V1.02.0.0 (March 2020)

・Add compatible instruments (RM3544, RM3542, RM3542A, RM3543, 3237, 3238)
・Logging start by EXT. TRIG(SW1001 EXT. I/O SCAN signal)
・Delay function
・Support communication command forwarding function
・Cole-Cole plot 72CH
・Cole-Cole plot voltage measurement
・Cole-Cole plot logging measurement
・IM3590 battery mode off supported



 
V1.01.0.0 (September 2018)
 First Release