NEW

BATTERY HiTESTER

BT3563A

Fully Automated Production Line Testing of Large Packs for xEVs or Large Packs of up to 300 V

Key Features • Simultaneous measurement of internal resistance and open circuit voltage. • Fully automated production line testing of large packs for xEVs or large packs of up to 300 V. • Resistance measurement ranges: 3 mΩ/30 mΩ/300 mΩ/3 Ω/30 Ω/300 Ω/3 kΩ • Voltage measurement ranges: 6 V/60 V/300 V • Equipped with LAN

Model No. (Order Code)

BT3563A

Note: Measurement leads are not included. Purchase the appropriate lead option for your application separately. The male (system side) of the EXT I/O connector is also available. Please contact your authorized Hioki distributor or reseller.

Guarantee3years
LAN
RS232C
CE

Measuring battery performance and safety using internal resistance (AC-IR) and open-circuit voltage (OCV)

Inspect the quality of completed cells, modules, and packs on production lines. Measure internal resistance (AC-IR) and open-circuit voltage (OCV) to check battery quality. Cells produced at the cell production factory are shipped to the module production factory after undergoing a shipping inspection. Since factors such as vibrations during shipment and even the passage of time can cause defects, batteries undergo an acceptance inspection before being assembled into modules and packs. BT3561A Small cells for power motors, Small packs of up to 60 V Voltage measurement ranges: 6 V/60 V Resistance measurement ranges: 30 mΩ/300 mΩ/3 Ω/30 Ω/300 Ω/3 kΩ BT3562A Large cells for xEVs, Mid-sized packs of up to 100 V Voltage measurement ranges: 6 V/60 V/100 V Resistance measurement ranges: 3 mΩ/30 mΩ/300 mΩ/3 Ω/30 Ω/300 Ω/3 kΩ BT3563A Large packs for xEVs, Large packs of up to 300 V Voltage measurement ranges: 6 V/60 V/300 V Resistance measurement ranges: 3 mΩ/30 mΩ/300 mΩ/3 Ω/30 Ω/300 Ω/3 kΩ


Reducing test system development cost and management man-hours

The new BT356xA has dramatically improved tolerances for line resistance compared to previous models. This improvement makes it easy to build test systems with large numbers of channels using relays. Additionally, a longer maintenance cycle for systems in use means fewer maintenance man-hours. Finally, its capability to handle thinner cables than with previous models* makes it easier to route cables. *AWG 29 (0.064 mm2) wire equivalent to 2.2 Ω over an 8 m round trip can be used with the 3 mΩ or 30 mΩ range.


Improve Productivity by Increasing the Number of Inspection Channels

You can use the Switch Mainframe SW1001/SW1002 to increase the number of measurement channels. Additionally, you can perform scan measurement by controlling two instruments at once, for example a BT356xA series instrument and a DM7276, or a BT4560 and a DM7276.


Preventing instrument malfunctions caused by static electricity

Batteries can become charged on production lines, for example, when being transported on a conveyor belt. When probes are placed in contact with such batteries, the resulting application of static electricity can then damage the instrument. The BT356xA series is designed to withstand contact with ±30 kV of static electricity*, preventing static-caused malfunctions and reducing testing line downtime. * ±30 kV IEC 61000-4-2 contact discharge


LAN interface as standard

The BT356xA series is equipped with a LAN interface as standard equipment, making it easy for the instrument to interoperate with a PLC*-based control system. The ability to use readily accessible LAN cables helps lower costs during system development and maintenance. Furthermore, a design with strong noise and static electricity resistance helps avoid system problems. *Programmable Logic Controller, a device that automatically controls one or more machines


The De Facto Standard of Battery Testers

The HIOKI BT356xA series These highly advanced battery testers are best suited for shipping and acceptance inspections of cells and battery packs. They simultaneously measure internal resistance and the battery’s open-circuit voltage (OCV). Since the AC-IR measurement method is used, the measurement time is shortened. In addition, highly repeatable results are attained with this method. These testers have a highly accurate 3 mΩ range, allowing for a resistance measurement of battery tab welding and bus bars. All of this combines for the best choice in battery testers. High input voltage applications The input high voltage (1,000 V) model, BT3564, can measure the total resistance of the battery whole pack at once. *Watch with the video subtitles on, to see detailed descriptions.


Basic specifications (Accuracy guaranteed for 1 year, Accuracy guarantee period after adjustment made by Hioki: 1 year)

Resistance measurement ranges3 mΩ(Max. display: 3.1000 mΩ, resolution: 0.1 μΩ, measurement current: 100 mA)
30 mΩ(Max. display: 31.000 mΩ, resolution: 1 μΩ, measurement current: 100 mA)
300 mΩ(Max. display: 310.00 mΩ, resolution: 10 μΩ, measurement current: 10 mA)
3 Ω(Max. display: 3.1000 Ω, resolution: 100 μΩ, measurement current: 1 mA)
30 Ω(Max. display: 31.000 Ω, resolution: 1 mΩ, measurement current: 100 μA)
300 Ω(Max. display: 310.00 Ω, resolution: 10 mΩ, measurement current: 10 μA)
3 kΩ(Max. display: 3.1000 kΩ, resolution: 100 mΩ, measurement current: 10 μA)

Basic accuracy: ±0.5% rdg ±10 dgt(3 mΩ range), ±0.5% rdg ±5 dgt(30 mΩ range or more)
Measurement frequency: 1 kHz ±0.2 Hz
Measurement method: AC four-terminal method
Voltage measurement ranges6 V(Max. display: 6.00000 V, resolution: 10 μV)
60 V(Max. display: 60.0000 V, resolution: 100 μV)
300 V(Max. display: 300.000 V, resolution: 1 mV)

Basic accuracy: ±0.01% rdg. ±3 dgt.
Response time10 ms
Sampling periodΩ or V (60 Hz): 4 ms (EX.FAST), 12 ms (FAST), 35 ms (MEDIUM), 150 ms (SLOW)
ΩV (60 Hz): 8 ms (EX.FAST), 24 ms (FAST), 70 ms (MEDIUM), 253 ms (SLOW)

Ω or V (50 Hz): 4 ms (EX.FAST), 12 ms (FAST), 42 ms (MEDIUM), 157 ms (SLOW)
ΩV (50 Hz): 8 ms (EX.FAST), 24 ms (FAST), 84 ms (MEDIUM), 259 ms (SLOW)
FunctionsContact check, Zero adjustment (±1000 counts), Pulse measurement, Comparator (Hi/ IN/ Lo), Statistical calculations (Max. 30,000), Delay, Average, Panel saving/loading, Memory storage, LabVIEW® driver
InterfacesLAN (TCP/IP, 10BASE-T/100BASE-TX)
RS-232C (Max. 38.4 kbps, Available as printer I/F)
EXT I/O (37-pin Handler interface)
Analog output (DC 0 V to 3.1 V)
Power supply100 to 240 V AC, 50 Hz/60 Hz, 35 VA max.
Dimensions and mass215 mm (8.46 in) W × 80 mm (3.15 in) H × 295 mm (11.61 in) D, 2.4 kg (84.7 oz)

Log into your myHioki account to access more technical documents and information where available.

Seminar Videos On Demand

No results were found.

Seminar Schedule

No results were found.

Catalogs

Preview: BATTERY HiTESTER BT3561A, BT3562A, BT3563A Download PDF  [1MB] English
Catalog: BATTERY TESTER Series Download PDF  [8MB] English

User Guides

Electrical Measurements of Lithium-Ion Batteries Download PDF  [4MB] English
Lead-acid Battery Handbook Download PDF  [1MB] English

Manuals

If you can not download, log into your myHioki account to access more technical documents and information where available.


Instruction Manual Simplified Chinese
Ver.06
Instruction Manual Korean
Ver.04
Instruction Manual English
Ver.09
Instruction Manual French
Ver.04
Instruction Manual German
Ver.04

Outline Drawings

If you can not download, log into your myHioki account to access more technical documents and information where available.



Ver.00

Technical Notes

No results were found.

Declaration of Conformity


Ver.00

Others

No results were found.

Options

Measurement leads (for measuring high voltage batteries)

TIP PIN 9772-90

To replace the tip on the Pin type lead 9772, L2100/L2110, (one piece)

PIN TYPE LEAD L2100

A: 300 mm (11.81 in.), B: 172 mm (6.77 in.), L: 1400 mm (4.59 ft.), for high voltage battery measurements, 1000 V DC max.

PIN TYPE LEAD L2110

A: 750 mm (29.53 in.), B: 215 mm (8.46 in.), L: 1880 mm (6.17 ft.), for high voltage battery measurements, 1000 V DC max.

Measurement Leads (for measuring batteries up to 60 V with small electrodes)

1.8 mm dia. single-axis type

PIN TYPE LEAD 9770

A: 260 mm (10.24 in.), B: 140 mm (5.51 in.), L: 850 mm (2.79 ft.), 60 V DC

Measurement Leads (for measuring batteries up to 60 V at thru holes and sub-millimeter objects)

0.2 mm parallel pyramid-type pins

PIN TYPE LEAD 9771

A: 260 mm (10.24 in.), B: 138 mm (5.43 in.), L: 850 mm (2.79 ft.), 60 V DC

Measurement Leads (for measuring batteries up to 60 V, others)

LARGE CLIP TYPE LEAD 9467

A: 300 mm (11.81 in.), B: 116 mm (4.57 in.), L: 1360 mm (53.54 in.), tip φ 29 mm (1.14 in.), 50 V DC

CLIP TYPE LEAD L2107

A: 130 mm (5.12 in.), B:84 mm (3.31 in.), L:1.1 m (3.61 ft.), 60 V DC

FOUR TERMINAL LEAD 9453

A: 280 mm (11.02 in.), B: 118 mm (4.65 in.), L: 1360 mm (4.46 ft.), 60 V DC

Zero adjustment board

Can not be used for Pin Type Lead 9770 and Pin Type Lead 9771

0 ADJ BOARD Z5038

For L2100, L2110, L2020, 9465-10, 9772

PC communication

RS-232C CABLE 9637

9 pin - 9 pin, cross, 1.8 m (5.91 ft) length

Applications

Gallery

No results were found.


  • Search


    Search Results Include Discontinued Products

    Login to myHIOKI

    Download

  • Ask

    • Ask Online

     

  • Quote

    • Request a Quote
    • Locate a Distributor

Related Products List