AC LEAKAGE CLAMP METER
CM4002
Prevent unexpected downtime! Identify potential problems and avoid large problems
Key Features • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary) • Detect minuscule leakage currents with a newly designed sensor. (Core jaw diameter up to φ 40 mm) • Broad measurement range extending from leakage currents to load currents • Complies with the performance standard set forth in IEC/EN 61557-13, an international standard on leak clamp meters • Solve GFCI and RCD problems quickly • Speed up pass/fail judgments with the built-in comparator function CAT IV 300 V CAT III 600 V
CM4002 | Wireless Adapter Z3210 not included |
---|---|
CM4002-90 | Bundled with the Wireless Adapter Z3210 |
Connect the Wireless Adapter Z3210 (optional) for wireless communications. You can transfer the readings to your phone or tablet and check the location and time of leakage easily and efficiently.
GENNECT Cross, a free app designed specifically for use with Hioki measuring instruments, lets you check and manage measurement results and create reports. The software provides a range of functionality that helps manage data in the field, including photographing measurement sites, placing measurement results on photographs, and saving hand written memos. Optional Wireless Adapter Z3210 is necessary.
The core and shielding are constructed from high-permeability magnetic materials. The CT sensor features a uniform coil. The CM4002/CM4003 complies with the performance standard set forth in IEC/EN 61557-13, an international standard on leak clamp meters.
1. Uniform measurement sensitivity inside jaws: When affixed around a wire, sensitivity is uniform regardless of the position of the conductor inside the jaws. 2. Resistance to the effects of external magnetic fields: Shielding made of high-permeability magnetic material blocks magnetic fields from the surrounding environment. 3. Elimination of the effects of highfrequency currents: A low-pass filter eliminates high-frequency capacitive leakage currents from inverters and other equipment.
AC Current range | 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, True RMS Basic accuracy 45 Hz - 400 Hz: ±1.0% rdg ±5 dgt (6.000 mA to 6.000 A), ±1.5% rdg ±5 dgt (60.00 A, 200.0 A) Basic accuracy 15 Hz - 45 Hz, 400 Hz - 2 kHz: ±2.0% rdg ±5 dgt Defined accuracy range: 0.060 mA to 200.0 A |
---|---|
AC Voltage range | N/A |
Frequency range | 15.0 Hz to 2000 Hz |
Crest factor | 3 (other than 200.0 A range), 1.5 (200.0 A range) |
Filter function | Cut off frequency: 180 Hz ±30 Hz at filter ON (-3 dB) |
Output function | N/A |
Other functions | Max/ Min/ AVG/ PEAK MAX/ PEAK MIN value display, Display value hold and auto hold; Backlight, Auto power save, Buzzer sound, Event count display, Comparator, Simple event recording, Rush current measurement |
Display | Display refresh rate: 5 times/s |
Power supply | AA-size alkaline battery (LR6) × 2; Continuous operating time: 48 hr. (without Z3210 installed), 30 hr. (with Z3210 installed and using wireless communications) |
Core jaw diameter | φ 40 mm (1.57 in.) |
Dimensions and mass | 64 mm (2.52 in) W × 233 mm (9.17 in) H × 37 mm (1.46 in) D, 400 g (14.1 oz.) |
Accessories | Carrying case C0203 × 1, Instruction manual × 1, Operating Precautions × 1, AA-size alkaline battery (LR6) × 2 |
Log into your myHioki account to access more technical documents and information where available.
No results were found. |
No results were found. |
Catalog: CLAMP METER Series | Download PDF [6MB] |
English |
Catalog: WIRELESS ADAPTER Z3210 | Download PDF [1MB] |
English |
Catalog: AC LEAKAGE CLAMP METER CM4002, CM4003 | Download PDF [2MB] |
English |
No results were found. |
If you can not download, log into your myHioki account to access more technical documents and information where available.
Instruction Manual |
Korean |
Ver.00 | |
Instruction Manual |
English |
Ver.00 | |
Instruction Manual |
Simplified Chinese |
Ver.00 | |
Instruction Manual |
Spanish |
Ver.00 | |
Instruction Manual |
German |
Ver.00 | |
Instruction Manual |
French |
Ver.00 | |
Instruction Manual |
Italian |
Ver.00 |
If you can not download, log into your myHioki account to access more technical documents and information where available.
AC LEAKAGE CLAMP METER CM4002 [135KB] |
Ver.00 |
No results were found. |
AC LEAKAGE CLAMP METER CM4002,CM4003 [118KB] |
Ver.00 |
DemoSheet-HIOKI | Freeware |
No results were found. |
WIRELESS ADAPTER Z3210
• Increase your work efficiency, by eliminating human errors from manual reporting • Transfer readings on instruments to easy-to-read graphical reports to prove integrity • Compliance with wireless regulations in more than 50 countries and regions
CARRYING CASE C0203
GENNECT CROSS SF4071, SF4072
• Mobile app for iOS, Android • Improve efficiency of operations that repeat measurement and recording • Analyze correlated data during issues and generate quick reports
No results were found.