1ms Sampling Portable Logger Expandable to 330 Channels with Your Choice of Plug-in or Wireless Input Modules
Hioki Memory HiLoggers are high-speed data loggers for recording multiple channels of voltage, temperature, resistance or humidity signals, some models providing complete isolation between channels and strong noise resistance. The LR8450-01 offers 1ms sampling across up to 330 channels, and can be paired with 10 different types of plug-in or wireless input units. Collect data from wireless modules installed in remote or confined locations via a LAN connection. New input modules measure strain and distortion, ideal for automotive applications involving the evaluation of vehicle components as well as robotic equipment. Key Features • Wireless LAN model expandable to 330 ch with wireless and plug-in units • Record voltage output from pressure and other sensors with 1ms sampling speed • Directly connect strain gauge and measure signals in as fast as 1ms intervals • Significantly reduced effects from noise let you safely measure in high voltage and high frequency areas such as around inverter motors • Avoid wiring issues by minimizing cable length using wireless units • Monitor data captured remotely on PC with wireless LAN technology
LR8450-01 | Wireless LAN equipped model, main unit only |
---|
・Memory HiLogger LR8450 and LR8450-01 cannot perform measurement on their own. One or more plug-in modules or wireless modules are required (sold separately). ・Memory HiLogger LR8450-01 and wireless modules emit radio waves. Use of radio waves is subject to licensing requirements in certain countries. Using it in a country or region other than those indicated may violate the law and may result in legal penalties. ・For the latest information about countries and regions where wireless operation is currently supported, please see the "Specifications."
Memory HiLogger LR8450-01 is a data logger equipped with wireless LAN. It is ideal for collecting data in dispersed locations and locations where wiring is difficult. You can add up to 7 wireless units and measure up to 330 channels. Will introduce to you two easy steps, to register the wireless units onto the main module.
The LR8450 reduces the effects of noise to deliver stable logging, even at high voltages and frequencies. Legacy data loggers could not log temperature accurately in noisy environments due to the effects of high frequencies, which caused values to shift or fluctuate significantly. The new Hioki Memory HiLogger LR8450 uses a revamped design to dramatically reduce the effects of high-frequency noise, and is ideal for temperature logging of inverters and batteries.
The Memory HiLogger LR8450 is a data logger that can measure stress via directly connected strain gages. Capable of recording at frequencies on the order of dozens of hertz thanks to sampling at up to 1 ms, the LR8450 is ideal for measuring stress and load on moving parts and strain on components such as brakes and pipes. And because it can accommodate a mix of various measurement units, the LR8450 can simultaneously measure strain, temperature, and voltage as necessary.
Work time can be reduced by using the LR8450-01 and wireless units, since only minimal wiring is required. If the measurement target is located in a lab, this approach eliminates the need to string wire and drill holes in the walls of the monitoring room where data is checked.
Max. number of connectable modules | 4 plug-in input modules + 7 wireless input modules |
---|---|
Connectable modules (Plug-in modules) | U8550, U8551, U8552, U8553, U8554 |
Connectable modules (Wireless modules) | LR8530, LR8531, LR8532, LR8533, LR8534 Supported V1.20 or later |
No. of measurement channels | Up to 120 ch with plug-in input modules, up to 330 ch with plug-in input modules and wireless input modules |
Pulse/logic input | [Number of ch] 8 ch (common GND, non-isolated, exclusive setting for pulse/logic input for individual channels) [Adaptive input format] Non-voltage contact, open collector, or voltage input [Count] 0 to 1000 M pulse, 1 pulse resolution [Rotational speed] 0 to 5000/n (r/s), 1/n (r/s) resolution, 0 to 300,000/n (r/min.), 1/n (r/min.) resolution, n: Number of pulses per rotation (1 to 1000) [Logic input] Records 1 or 0 for each recording interval |
Recording intervals | 1 ms*, 2 ms*, 5 ms* (*: Can be set only when using 1 ms/S modules), 10 ms to 1 hour, 22 selections (Data refresh interval can be set for each unit |
Data storage | SD Memory Card/USB Drive (user-selectable) (Only storage media sold by HIOKI are guaranteed for operation) |
LAN interface | 100BASE-TX / 1000BASE-T, DHCP, DNS support, Functions: Data acquisition, condition settings used with the Logger Utility software, configuring settings and controlling recording using communications commands, FTP server / FTP client, HTTP server, Email transmission, NTP client |
Wireless LAN interface | IEEE 802.11b/g/n Communications range: 30 m, line of sight Encryption function: WPA-PSK/WPA2-PSK, TKIP/AES Usable channels: 1 to 11 Supported modes: Wireless unit connectivity, access point, station Functions: Configuring settings and controlling recording using communications commands, FTP server / client, HTTP server, Email transmission, NTP client |
USB interface | Series A receptacle × 2: USB 2.0 compliant (USB drive, keyboard, or hub)) Series mini-B receptacle × 1: Data acquisition, condition settings used with the Logger Utility, configuring settings and controlling recording using communications commands, transferring data from a connected SD Memory Card to a computer |
SD card slot | SD standard-compliant slot × 1 (with SD memory card/SDHC memory card support), Guaranteed-operation options: Z4001, Z4003 |
Display | 7 inch TFT color liquid crystal display (WVGA 800 × 480 pixel) |
Functions | Save waveform data in real time to the SD memory card or USB drive, numerical value calculations, waveform calculations, 8ch alarm output, voltage output ×2 (5 V /12 V /24 V selectable) |
Power supply | [AC adapter] Using the Z1014 (100 to 240 V AC, 50/60 Hz), 95 VA Max. (including AC adapter), 28 VA Max. (exclusive of AC adapter) [Battery Pack] Using the Z1007 (accommodates 2 batteries), continuous use 4 hr (reference value for 2 pieces), 20 VA Max. [External power] 10 to 30 V DC, 28 VA Max. (Please contact your HIOKI distributor for connection cord) |
Dimensions and mass | Without any modules: 272 mm (10.71 in) W × 145 mm (5.71 in) H × 43 mm (1.69 in) D (excluding protrusions), 1108 g (39.1 oz) (excluding battery pack) With 2 modules: 272 mm (10.71 in) W × 198 mm (7.80 in) H × 63 mm (2.48 in) D (excluding protrusions) With 4 modules: 272 mm (10.71 in) W × 252 mm (9.92 in) H × 63 mm (2.48 in) D (excluding protrusions) |
Accessories | Quick Start Manual ×1, LOGGER Application Disc (Quick Start Manual, Instruction Manual, Logger Utility, Logger Utility Instruction Manual, Communication Instruction Manual) ×1, USB Cable ×1, AC Adapter Z1014 ×1, Precautions Concerning Use of Equipment that Emits Radio Waves ×1 |
Countries and regions where wireless operation is currently supported | Austria, Belgium, Bulgaria, Canada, Chile, China, Colombia, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Georgia, Germany, Greece, Hong Kong, Hungary, Iceland, Ireland, Italy, Japan, Kenya, Korea, Latvia, Liechtenstein, Lithuania, Luxembourg, Macao, Malaysia, Malta, Myanmar, Netherlands, Norway, Poland, Portugal, Romania, Singapore, Slovakia, Slovenia, Spain, Sweden, Switzerland, Taiwan, Thailand, Turkey, United Kingdom, United States |
---|---|
Note | Use of devices that emit radio radiation requires approval in the country of use. Thus, use of the instrument in a country or region where they have not been approved may be subject to penalty as a violation of law. |
Log into your myHioki account to access more technical documents and information where available.
No results were found. |
No results were found. |
Catalog: GENNECT ONE SF4000 | Download PDF [4MB] |
English |
Catalog: MEMORY HiLOGGER LR8450 | Download PDF [4MB] |
English |
Catalog: Motor Measurement Applications | Download PDF [4MB] |
English |
No results were found. |
If you can not download, log into your myHioki account to access more technical documents and information where available.
Instruction Manual |
Japanese English |
Ver.01 | |
VOLTAGE/TEMP UNIT U8550, UNIVERSAL UNIT U8551,VOLTAGE/TEMP UNIT U8552, HIGH SPEED VOLTAGE UNIT U8553, STRAIN UNIT U8554 [2MB] |
Instruction Manual |
Japanese English |
Ver.01 |
WIRELESS VOLTAGE/TEMP UNIT LR8530,LR8532 WIRELESS UNIVERSAL UNIT LR8531 WIRELESS HIGH SPEED VOLTAGE UNIT LR8533 WIRELESS STRAIN UNIT LR8534 [2MB] |
Instruction Manual |
Japanese English |
Ver.00 |
MEMORY HiLOGGER LR8450-01 [878KB] |
Precautions Concerning Use of Equipment that Emits Radio Waves |
Japanese English |
Ver.02 |
WIRELESS LAN ADAPTER Z3230 [2MB] |
Instruction Manual |
Japanese English |
Ver.02 |
LOGGER UTILITY SF1000 [24MB] |
Instruction Manual |
English |
Ver.12 |
MEMORY HiLOGGER LR8450,LR8450-01 [6MB] |
Quick Start Manual |
English |
Ver.02 |
MEMORY HiLOGGER LR8450,LR8450-01 [6MB] |
Quick Start Manual |
Korean |
Ver.01 |
MEMORY HiLOGGER LR8450,LR8450-01 [16MB] |
Instruction Manual |
English |
Ver.02 |
MEMORY HiLOGGER LR8450,LR8450-01 [16MB] |
Instruction Manual |
Korean |
Ver.01 |
MEMORY HiLOGGER LR8450,LR8450-01 [8MB] |
Quick Start Manual |
Simplified Chinese |
Ver.01 |
MEMORY HiLOGGER LR8450,LR8450-01 [15MB] |
Instruction Manual |
Simplified Chinese |
Ver.01 |
If you can not download, log into your myHioki account to access more technical documents and information where available.
MEMORY HiLOGGER LR8450,LR8450-01 [134KB] |
Ver.01 |
MEMORY HiLOGGER LR8450,LR8450-01 [237KB] |
Ver.01 |
MEMORY HiLOGGER LR8450,LR8450-01 [313KB] |
Ver.01 |
No results were found. |
MEMORY HiLOGGER LR8450,LR8450-01 [30KB] |
Ver.00 |
WIRELESS LOGGING STATION LR8410 MEMORY HiLOGGER LR8400 LR8401 LR8402 8423 LabVIEW 2011 driver and Communication command manual | Freeware | Version 1.01 |
Communication commands manual and LabVIEW 2019 driver for LR8450, LR8416, LR8410, LR8400, LR8401, LR8402 and 8423 | Freeware | V1.02 |
Logger Utility/Wireless Logger Collector for Models 8423,8430-20,LR8400-20,LR8400-23,LR8401-20,LR8402-20,LR8410-20,LR8431-20,LR8512,LR8513,LR8514,LR8515,LR8520,LR8400-92,LR8400-93,LR8450 and LR8450-01 | Freeware | V1.94 (Logger Utility)/V1.07 (Wireless Logger Collector) |
MEMORY HiLOGGER LR8450, LR8450-01 | Firmware | Main Unit V1.50 / Wireless Input Unit V1.01 |
GENNECT One | Freeware | V4.11 |
No results were found. |
STRAIN UNIT U8554
Strain, voltage, strain gage-type converter, 5 ch, 1 ms sampling Strain, voltage, strain gauge transducer, 5 ch, 1 ms sampling
VOLTAGE/TEMP UNIT U8552
Voltage, thermocouple, humidity measurement, 30 ch, 20 ms sampling, 10 ms when the number of channels used is 15 or less
UNIVERSAL UNIT U8551
Voltage, Thermocouple, Humidity, Pt100/1000, JPt100, Resistance measurement, 15 ch, 10 ms sampling
VOLTAGE/TEMP UNIT U8550
Voltage/thermocouple/humidity measurements, 15 ch, 10 ms sampling
Connected only to the LR8450-01
WIRELESS STRAIN UNIT LR8534
Strain, voltage, strain gauge transducer, 5 ch, 1 ms sampling
WIRELESS VOLTAGE/TEMP UNIT LR8532
Voltage and thermocouple measurement, 30 ch, 20 ms sampling, 10 ms sampling when the number of channels used is 15 or less
WIRELESS UNIVERSAL UNIT LR8531
Voltage, Thermocouple, Humidity, Pt100/1000, JPt100, Resistance measurement, 15 ch, 10 ms sampling
WIRELESS VOLTAGE/TEMP UNIT LR8530
Voltage and thermocouple measurement, 15 ch, 10 ms sampling
Thermocouple
*For reference only. Please purchase locally.
HUMIDITY SENSOR Z2000
(Analog output), 3 m (9.84 ft) length
Precaution on purchasing memory device
Use only the memory device sold by HIOKI. Compatibility and performance are not guaranteed for memory device made by other manufacturers. You may be unable to read from or save data to such devices.
SD MEMORY CARD 2GB Z4001
2 GB capacity
SD MEMORY CARD Z4003
8 GB capacity
USB DRIVE Z4006
16 GB, Long-life, High-reliability SLC Flash Memory
*AC adapter is bundled with the LR8450, LR8450-01
BATTERY PACK Z1007
Li-ion, charges while installed
AC ADAPTER Z1014
100 to 240 V AC
CARRYING CASE C1012
Includes space for options
FIXED STAND Z5040
For installing logger on wall
LOGGER UTILITY is a bundled software, Real-time data collection will be supported by version upgrade
LOGGER UTILITY SF1000
• For the HIOKI Memory HiLoggers • The control of the measurement of loggers, real-time data collection • Wavefrorm display, data conversion, calculation, search, print
LAN CABLE 9642
Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m (16.41 ft) length
GENNECT ONE SF4000
• Automatically pair with LAN-connected measuring instruments • Display acquired data graphically in real-time • Windows compatible
MEMORY HiLOGGER LR8450
• Compatible with plug-in modules only • 5 to 120 ch of isolated input • DC V, temperature, resistance, distortion, etc. • Fastest recording interval: 1 ms