CURRENT PROBE
CT6710
Capture Inrush, Micro and High-Speed Currents with a Single Probe
Hioki flat bandwidth current probes are best-in-class current sensors for use with Memory HiCorders and high performance oscilloscopes. The CT6710 is a 3-range, high-sensitivity current probe that offers a wide DC to 50 MHz bandwidth and 200 μA to 30 A input, letting your capture signals across an expansive current range, from steady state to transient currents, when developing switching power supplies, inverters, and motor controllers. Key Features • 3 ranges in a single probe - 30 A, 5 A, 0.5 A. Observe a wide current range from micro currents to 30 A. • Wide band: DC to 50 MHz (-3 dB) • High S/N ratio and 10 times output rate: Observe waveforms at 100 μA/div at oscilloscope maximum voltage sensitivity setting of 1 mV/div • Directly connect to an oscilloscope’s BNC input terminal *1 • Also available: CT6711 Current Probe with DC to 120 MHz bandwidth *1: Connecting the probe's metal BNC terminal to a Memory HiCorder’s plastic BNC terminal may distort or damage the plastic terminal. To avoid damage, please connect and disconnect the probe cable straight to the BNC terminal of the waveform monitoring equipment.
CT6710 | From 200μA, 50MHz bandwidth |
---|
Note: If power cannot be supplied from the Memory HiCorder, the optional Power Supply 3269 is required. Please pay attention to offset drift during continuous, long-term measurement.
Monitor current under a broad range of operating conditions from 0.5 to 30A. Simply press the RANGE key on the termination box to toggle between ranges, and analyze everything from sudden inrush to slow moving consumption current, down to micro currents of low energy devices, all with a single device.
When input exceeds the rated value, a warning indicator flashes to signal a warning. In addition, if you select the incorrect range and then input a current signal that is above the rated current for that range, this function protects the instrument from damage due to overheating. Caution: Input currents that exceed the frequency derating for the 30 A range may cause measurement circuit damage before the protection function kicks in.
Observe waveforms as they are without needing to rely on your oscilloscope’s filter settings and averaging function. The 10V/A output rate is 10 times the traditional 1V/A rate of legacy products, allowing you to improve the oscilloscope’s voltage sensitivity by a factor of 10, thereby enhancing the S/N ratio of the scope itself to deliver much clearer waveforms.
Frequency bandwidth | DC to 50 MHz (-3 dB) |
---|---|
Rise time | 7.0 ns or shorter |
Delay time (Typical) | 30 A range: 12 ns, 5 A range: 12 ns, 0.5 A range: 13 ns (Delay time relative to rising waveform of input signal 1 ns) |
Noise level | 75 μA rms max (at 0.5 A range, using 20 MHz band measuring instrument) |
Max. rated current | 30 A range: 30 A rms, 5 A range: 5 A rms, 0.5 A range: 0.5 A rms (DC, and sine wave, requires derating at frequency) |
Max. allowable peak current | 30 A range: ±50 A peak (within the input limit time 2 s) 5 A range: ± 7.5 A peak, 0.5 A range: ± 0.75 A peak (< 10 MHz), ±0.3 A peak (≥ 10 MHz) |
Amplitude accuracy | 30 A range: ±3.0% rdg. ±1 mV, (Typical) ±1.0% rdg. ±1 mV (≤ 10 Arms, DC, 45 to 66 Hz sine wave, within the maximum peak current of each range) 5 A range: ±3.0% rdg. ±1 mV, (Typical) ±1.0% rdg. ±1 mV (DC, 45 to 66 Hz sine wave, within the maximum peak current of each range) 0.5 A range: ±3.0% rdg. ±10 mV, (Typical) ±1.0% rdg. ±10 mV (DC, 45 to 66 Hz sine wave, within the maximum peak current of each range) |
Output rate | 30 A range: 0.1 V/A, 5 A range: 1 V/A, 0.5 A range: 10 V/A, (The output of this probe is internally terminated, so connect to voltage input equipment with high input impedance such as 1MΩ) |
Measurable conductors | φ 5 mm (0.20 in), Insulated conductor |
Power supply | Supplied from Power Supply 3269, Probe Power Unit Z5021 |
Cable length | Sensor cable (between relay box and sensor): 1.5 m (4.92 ft) Power cable: 1.0 m (3.28 ft) (Power plug: FFA.0S.304.CLAC37Y / LEMO inc.) |
Dimensions and mass | Sensor: 155 mm (6.10 in)W × 18 mm (0.71 in)H × 26 mm (1.02 in)D, Relay box section: 45 mm (1.77 in)W × 120 mm (4.72 in)H × 25 mm (0.98 in)D Terminator section: 29 mm (1.14 in)W × 83 mm (3.27 in)H × 40 mm (1.57 in)D mm, 370 g (13.1 oz) |
Accessories | Instruction manual ×1, Carrying case ×1 |
Log into your myHioki account to access more technical documents and information where available.
No results were found. |
No results were found. |
Catalog: HIGH ACCURACY / WIDEBAND CURRENT SENSOR Series CT686x, CT687x, CT684x | Download PDF [6MB] |
English |
Catalog: CURRENT PROBE CT6710, CT6711 | Download PDF [2MB] |
English |
No results were found. |
If you can not download, log into your myHioki account to access more technical documents and information where available.
CURRENT PROBE CT6710,CT6711 [4MB] |
Instruction Manual |
English |
Ver.01 |
If you can not download, log into your myHioki account to access more technical documents and information where available.
CURRENT PROBE CT6710 [95KB] |
Ver.00 |
CURRENT PROBE CT6710,CT6711 [119KB] |
Ver.01 |
No results were found. |
No results were found. |
POWER SUPPLY 3269
• 2 channels for CT6710 series or 4 channels for CT6700 and 3270 series • ±12 V output
PROBE POWER UNIT Z5021
Specified upon order of the MR6000, power max. 4 × CT6710 series, or max. 8 × other probes
No results were found.