NEW

SWITCH MAINFRAME

SW1002

Packed with Features to Ensure Accuracy in Battery Measurements

Key Features • Switch between voltmeter and battery tester while testing • 264 channels max. (2-wire) to 72 channels max. (4-terminal pair) • Circuit design friendly for impedance measurements that minimize errors between channels (Effect: 0.01% f.s.*) * For BT4560 100 mΩ range, R measurements, and a measurement frequency of 1 kHz • For OCV measurement, internal resistance measurement, and external potential measurement of battery cells • Measure battery modules up to 60 V DC

Model No. (Order Code)

SW1002

Note: Multiplexer Modules not included with the switch mainframe SW1001 / SW1002. Modules must be purchased separately.

Guarantee3years
LAN
RS232C
USB2
CE

Multi-channel Battery Testing.Packed with Features to Ensure Accuracy

Combine the SW1002 with a battery testing instrument to measure a battery cell's OCV (open circuit voltage), internal resistance, reaction resistance at low frequency, Cole-Cole plot, and external potential on multiple channels.


Connect Up to Two Measuring Instruments with Different Functions

Switch between two types of measuring instruments to perform a variety of measurements.


Battery Measurement Supported by Exclusive PC Application

Use the free, downloadable PC application to perform various measurements easily.


Circuit Design for Impedance Measurements

The effect on the detection signal is reduced by canceling the magnetic flux of the AC measurement current and separating the source from the sense.


Choose from Two Types of Multiplexer Modules

MULTIPLEXER MODULE SW9001:This module supports 2-wire/4-wire configurations. Channel switching can be performed in 11 ms (excluding communication, command processing time, and contact bounce). MULTIPLEXER MODULE SW9002: This module supports 4-terminal pair configuration for use in combination with BT4560 and IM3590. 2-wire measurement is also possible (Sense only). Channel switching can be performed in 11 ms (excluding communication, command processing time, and contact bounce).


Communication Command Transmission Function Reduces the Number of PC Ports Needed

Normally, PC control requires two ports: one communication port for switching and one for the measuring instrument. By using the communication command transmission function on the SW1002 the switch mainframe can transfer control commands from the PC to the measuring instrument (and responses can be received from the device). This allows you to reduce the number of communication ports used on the measuring instrument


Scan Function

This function switches between channels in order based on the scan list registered in advance. The switch mainframe and the EXT. I/O of the measuring instrument are connected. With the scan function, channel switching and trigger measurement can be synced for continuous scanning.


Basic specifications

Slots12 slots
Supported modulesMULTIPLEXER MODULE SW9001 (2-wire/4-wire)
MULTIPLEXER MODULE SW9002 (4-terminal pair)
Connectible instrumentsMax. 2 units
2-wire × 1 + 4-wire × 1, or 2-wire × 1 + 4-terminal pair × 1
Maximum input voltage60 V DC (Cannot connect to battery packs in excess of 60 V DC), 30 V AC rms, 42.4 V peak, Maximum rated voltage to ground: 60 V DC
Communication I/FLAN, USB, RS-232C (for host, for measurement instruments)
FunctionsChannel switching, wiring method, scan function, communication command transmission, channel delay, shield switching
Power supply100 to 240 V AC / 30 VA (50/60 Hz)
Dimensions and mass430 mm (16.93 in) W × 132 mm (5.20 in) H × 420 mm (16.54 in) D, 6.0 kg (211.6 oz)
AccessoriesPower cord ×1, instruction manual ×1, usage precautions ×1, USB driver CD ×1

Basic specifications for MULTIPLEXER MODULE

SW9001SW9002
Wiring method2-wire or 4-wire4-terminal pair (6-wire) or 2-wire
No. of channels22 channels (2-wire) / 11 channels (4-wire)6 channels (4-terminal pair) / 6 channels (2-wire)
Contact methodArmature relays
Channel switching time11 ms (excluding measurement time)
Max. allowable voltage60 V DC, 30 V AC rms, 42.4 V peak
Max. allowable current1 A DC, 1 A AC rms1 A DC, 1 A AC rms (Sense), 2 A DC, 2 A AC rms (Source, Return)
Max. allowable power30 W (resistive load)
Maximum rated voltage to ground60 V DC
Dimensions and mass25.5 mm (1.00 in) W × 110 mm (4.33 in) H × 257 mm (10.12 in) D, 210 g (7.4 oz)25.5 mm (1.00 in) W × 110 mm (4.33 in) H × 257 mm (10.12 in) D, 196 g (6.9 oz)
AccessoriesInstruction manual ×1

Log into your myHioki account to access more technical documents and information where available.

Seminar Videos On Demand

No results were found.

Seminar Schedule

Registration Open

EPE'18 ECCE Europe - Latvia

Sep 17, 2018 - Sep 21, 2018

Registration Open

IEEE Industrial Expo - Acapulco, Mexico

Jul 15, 2018 - Jul 20, 2018

Catalogs

Catalog: SWITCH MAINFRAME SW1001, SW1002 Download PDF  [3MB] English

User Guides

No results were found.

Manuals

Instruction Manual English
Ver.00
License Information Japanese
English
Ver.00

Outline Drawings


Ver.00

Technical Notes

No results were found.

Declaration of Conformity


Ver.00

Drivers, Firmware

No results were found.

Others

No results were found.

Options

Modules

MULTIPLEXER MODULE SW9001

2-wire/4-wire

MULTIPLEXER MODULE SW9002

4-terminal pair

Connection Cables

CONNECTION CABLE SET L4930

1.2 m (3.94 ft) length

CONNECTION CABLE L2108

4-Terminal banana, 0.84 m (2.76 ft) length

CONNECTION CABLE L2004

BNC, 0.91 m (2.99 ft) length

Interface Cables

RS-232C CABLE 9637

For the PC, 9 pin - 9 pin, cross, 1.8 m (5.91 ft) length

LAN CABLE 9642

Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m (16.41 ft) length