MEMORY HiCORDER
MR6000
Highest Measurement Capabilities and Fastest Transfer Rate in History
The MR6000 overcomes all barriers to reach new ground and meet challenges that are yet to be seen. World class specifications, operability and design - Hioki’s newest memory recorder has been re-engineered from top to bottom, delivering unprecedented performance that will change how you look at waveform recording. Key Features • High-speed 200 MS/s isolated testing (with High Speed Analog Unit U8976Ax8) • Simultaneously measure up to 32 analog channels (with 4ch Analog Unit U8975x8) • Real-time saving of data of all 32 ch at 1 MS/s (with SSD Unit U8332) • Highly-responsive touchscreen • Memory Concierge: Easily search for the waveform you want to see with the waveform search function • Faster save times (1/10th the time required by legacy models) • Real-time digital filter calculation
MR6000 | Main unit only, input modules up to 8 units |
---|---|
MR6000-01 | Built-in real-time waveform calculation and other functionality |
FREQUENTLY ASKED QUESTIONS Note: Main unit MR6000/MR6000-01 cannot operate alone. You must install one or more optional input modules in the unit.
Combine the CURRENT UNIT 8971 and a current probe or current sensor designed and manufactured by Hioki to use the system within a wide temperature range or measure large currents with a high level of precision at solar power plants or development sites for EVs/HEVs. The convenient, built-in sensor identification function lets you simply connect the sensor to easily configure the scaling settings through automatic recognition. Combine the HIGH SPEED ANALOG UNIT U8976 and a Hioki current probe or clamp-on probe for high-precision wideband observation of current waveforms.
The new flagship memory recorder MR6000 from HIOKI delivers 200MS/s sampling, touchscreen operability, and advances functions to help you find the waveform you need quickly out of overwhelming amounts of data. Measure inverter and switching power supply signals with direct high voltage input.
Connections between analog input channels, and between the input channel and the main unit, are fully isolated. This means that, unlike an oscilloscope,measurements can be made without concern with negative effects from potential differences. << optical isolation devices (HIGH SPEED ANALOG UNIT U8976)
The new Hioki MR6000 Memory HiCorder is engineered with a brand new interface that delivers a data transfer speed to external media that is as fast as 32 times the previous model. With this capability, the time it takes to save measured waveforms to external media is dramatically reduced, boosting test efficiency. In addition, while legacy recorders only allowed users to transfer 1 channel of data measured at 1MS/s, the MR6000 can transfer 32 channels of data all at the same time. (Data transfer speeds may differ depending on actual measurement conditions.)
Combine multiple units to record a range of phenomena. Choose the HIGH-VOLTAGE UNIT U8974 with a direct input of 1000 V DC to measuring global power lines, including uninterruptible power supplies (UPS) and commercial power supplies. Use multiple logic units to measure relay ON/OFF signals or PLC (programmable logic controller) signals across up to 128 channels simultaneously.
Avoid the need to wait to transfer very large amounts of data measured over a long period of time. The MR6000 features a brand new interface and faster internal processing, reducing the time required to save measurement data to media. This saves you the trouble of waiting for data to be saved and improves work efficiency.
The capacitive touch screen delivers intuitive operability. Select a setting item directly by tapping the screen, and use your fingers to enlarge the part you want to see. The new user interface makes setting measurement items for multiple channels easier compared to the more complicated conventional models where you had to press the keys several times to configure a setting.
Our search for a touch screen with the best operability and visibility angle led us to develop retractable feet that maximize those two important attributes. Tilting the MR6000 with the feet reduces the strain on your wrists when you use the device on a desk, and keeps your line of sight at a natural level. The rear side also features the same retractable feet, making is easy to use the device on the floor.
We have achieved a design that is compact while still delivering blazing fast processing speeds by using thermal liquid analysis to optimally position the air inlets, heating components, and cooling fans. The smaller form factor requires less space for installation, making the device just right for tight workspaces. * When compared to the legacy Hioki Model 8861-50.
The rubber handle boasts excellent grip and makes it easy to carry the device with either one or both hands. The grips on either side of the device can also be used to lift it with both hands. Simple protectors on the top and bottom right side of the device protect the interface and unit input terminals from sudden physical shocks.
The sensing technology that serves as the inlet for measurement data is essential for detecting various phenomena in multiple channels. The MR6000 is a high-spec model that fully utilizes the capacity of Hioki's high-precision sensors. Furthermore, install the optional PROBE POWER UNIT Z5021 to drive these probes from the MR6000 main unit.
The system uses the envelope measurement method to record maximum and minimum values at set intervals while performing oversampling at 100 MS/s. The internal memory has a capacity of 1 G-words, which ensures that the measuring process continues for a long time without any data losses. Save data in real time while measuring.
The MR6000-01 features powerful optional equipment for real-time waveform processing. This function performs the four arithmetic operations (addition, subtraction, multiplication, and division), differentiation calculations, or integration calculations during the measuring process. This lets you use waveforms to check the calculation results while measuring. The equipment also saves and computes the calculation results numerically after the measuring process.
MR6000 | MR6000-01 | |
Additional function | N/A | Real-time waveform calculation, Digital Filter calculation |
Number of input units | Max. 8 units | |
Number of channels | Max. 32 analog channels (when using the U8975), or 128 logic channels (when using the 8973) | |
Measurement ranges (20 div full-scale) | 10 mV to 400 V f.s., 12 ranges (when using the U8976), Resolution : 1/1600 of range 4 V to 200 V f.s., 6 ranges (when using the U8975), Resolution : 1/32000 of range | |
Max. allowable input | 400 V DC (when using the U8976), 200 V DC (when using the U8975) | |
Frequency characteristics | DC to 30 MHz (when using the U8976), DC to 2 MHz (when using the U8975) | |
Max. sampling rate | 200 MS/s, all channnels simultaneously (when using the U8976) External sampling: 10 MS/s | |
Recording methods | Normal: Normal waveform recording Envelope: Record maximum and minimum values every fixed period | |
Storage memory capacity | 1 G-words | |
Removable storage | SD memory card ×1, USB memory ×7, SSD/HDD (built in the main unit) ×1 FTP transmission (to LAN-connected computer) *Use only Storage Media sold by HIOKI. | |
Display | 12.1 inch XGA-TFT color LCD (1024 × 768 dots) | |
External interfaces | LAN, USB, SD, SATA, Monitor output | |
Power supply | 100 to 240 V AC (50/60 Hz) (300 VA max.) | |
Dimensions and mass | 353 mm (13.9 in)W × 235 mm (9.25 in)H × 154.8 mm (6.09 in)D, 6.5 kg (229.3 oz) (main unit only) | |
Accessories | Power cord ×1, Quick start manual ×1, Precautions conserning use ×1, Application disk (CD-R) ×1, Instruction manual (CD-R, detail and calculation) ×1 , Blank panel (for blank slots only) |
Log into your myHioki account to access more technical documents and information where available.
No results were found. |
![]() |
Nov 25, 2019 - Nov 28, 2019 | |
![]() |
Nov 25, 2019 - Nov 28, 2019 |
Catalog: MEMORY HiCORDER MR6000 | Download PDF [9MB] |
English |
Catalog: GENNECT ONE SF4000 | Download PDF [1MB] |
English |
Preview Catalog: MR6000 Viewer | Download PDF [945KB] |
English |
No results were found. |
If you can not download, log into your myHioki account to access more technical documents and information where available.
MEMORY HiCORDER MR6000,MR6000-01 [11MB] |
Quick Start Manual |
English |
Ver.01 |
MEMORY HiCORDER MR6000,MR6000-01 [13MB] |
Instruction Manual |
English |
Ver.01 |
MEMORY HiCORDER MR6000-01 [3MB] |
MR6000-01 Dedicated Functions |
English |
Ver.01 |
MEMORY HiCORDER MR6000, MR6000-01 [7MB] |
Quick Start Manual |
Simplified Chinese |
Ver.00 |
MEMORY HiCORDER MR6000, MR6000-01 [9MB] |
Instruction Manual |
Simplified Chinese |
Ver.00 |
MEMORY HiCORDER MR6000-01 [2MB] |
MR6000-01 Dedicated Functions |
Simplified Chinese |
Ver.00 |
If you can not download, log into your myHioki account to access more technical documents and information where available.
MEMORY HiCORDER MR6000 [461KB] |
Ver.02 |
MEMORY HiCORDER MR6000 (With Probe Power Unit Z5021) [185KB] |
Ver.02 |
MEMORY HiCORDER MR6000-01 [178KB] |
Ver.02 |
MEMORY HiCORDER MR6000-01 (With PROBE POWER UNIT Z5021) [183KB] |
Ver.02 |
Memory HiCorder MR6000/MR6000-01, 4ch Analog Unit U8975, High Speed Analog Unit U8976 [671KB] |
MEMORY HiCORDER MR6000,MR6000-01 [108KB] |
Ver.00 |
MATLABscript for MEMORY HiCORDERs (8860-50(51) 8861-50(51) MR8827 MR8847(A) MR8875 MR8740 MR8741 MR6000 MR8740T) | Freeware | V2.10 |
GENNECT One | Freeware | V3.01 |
MEMORY HiCORDER Model MR6000 MR6000-01 LabVIEW 2017 driver | Freeware | V1.00 |
Wave Viewer (Wv) | Freeware | Version 1.42 |
FAMOS Import Filter | Freeware | V1.01 |
MR6000 Viewer | Freeware | V2.11 |
MEMORY HiCORDER & MEMORY HiLOGGER Application Disk | Freeware | Rev 42 |
MEMORY HiCORDER MR6000 MR6000-01 | Firmware | V2.13 |
No results were found. |
*Must specify when ordering
*Power can be supplied to up to 8 current sensors, including the current sensors connected to the CURRENT UNIT 8971.
PROBE POWER UNIT Z5021
Specified upon order of the MR6000, power max. 4 × CT6710 series, or max. 8 × other probes
*Must specify when ordering
SSD UNIT U8332
Specified upon order, built-in type, 256 GB
*Must specify when ordering
HD UNIT U8333
Specified upon order, built-in type, 320 GB
*Precaution
*Use only the storage media sold by HIOKI. Compatibility and performance are not guaranteed for storage media made by other manufacturers. You may be unable to read from or save data to such media.
SD MEMORY CARD 2GB Z4001
2 GB capacity
SD MEMORY CARD Z4003
8 GB capacity
USB DRIVE Z4006
16 GB, Long-life, High-reliability SLC Flash Memory
*Input cords not included. Please purchase separately.
*When using 9709 with CURRENT UNIT 8971, a total of 7 current probes can be used.
HIGH VOLTAGE UNIT U8974
・ 2 ch, High-voltage input ・ Max. 1000 VDC, 700 VAC rms ・ DC to 100 kHz bandwidth
DC/RMS UNIT 8972
• 2 ch, instantly waveform/RMS • DC to 400 kHz bandwidth • RMS: DC and 30 to 100 kHz
CURRENT UNIT 8971
• 2 ch, measuring current • DC to 400 kHz bandwidth • Direct connectable with current sensors
DIGITAL VOLTMETER UNIT MR8990
・ For minute voltage measurement ・ Max. 0.1 μV resolution ・ 500 times/s sampling
STRAIN UNIT U8969
• 2 ch, acceleration, load, pressure or strain • Strain gauge converter amp
CHARGE UNIT U8979
・ Measure acceleration waveforms across 2 channels ・ Charge output type acceleration pickup ・ Preamplifier built-in acceleration pickup
CONNECTION CABLE L9795-01
Max. rated voltage to earth: 33 Vrms AC or 70 V DC, SMB to alligator clip, 1.5 m (4.92 ft) length
CONNECTION CABLE L9795-02
Max. rated voltage to earth: 33 Vrms AC or 70 V DC, SMB to BNC terminal, 1.5 m (4.92 ft) length
*Voltage is limited to the specifications of the input modules in use.
CONNECTION CORD L9790
• Flexible φ 4.1 mm (0.16 in) thin dia. • Cable allowing for up to 600 V input • 1.8 m (5.91 ft) length
ALLIGATOR CLIP L9790-01
Red/black set attaches to the ends of the Connection Cord L9790
GRABBER CLIP 9790-02
Red/black set attaches to the ends of the Connection Cord L9790
CONTACT PIN 9790-03
Red/black set attaches to the ends of the Connection Cord L9790
*Voltage is limited to the specifications of the input modules in use.
CONNECTION CORD L9198
•φ 5.0 mm (0.20 in) dia. •Cable allows for up to 300 V input •1.7 m (5.58 ft) length •Small alligator clip
CONNECTION CORD L9197
•φ 5.0 mm (0.20 in) dia •Cable allows for up to 600 V input •1.8 m (5.91 ft) length •Includes detachable large alligator clips
GRABBER CLIP 9243
Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V
*Voltage is limited to the specifications of the input modules in use.
10:1PROBE 9665
・1 kV rms Max. (500 kHz or less) ・Max. rated voltage to earth depends on input unit.
100:1PROBE 9666
・5 kV peak Max. (1 MHz or less) ・Max. rated voltage to earth depends on input unit.
*Voltage to ground is within this product's specifications. *Separate power source is also required.
DIFFERENTIAL PROBE P9000
• Waveform only for exclusive use with Memory HiCorders (P9000-01) or waveform/RMS value switchable (P9000-02) • For use with input of up to 1 kV AC/DC • Requires separate power supply
AC ADAPTER Z1008
100 to 240V AC
(1) Bus powered USB cable
(2) USB(A)- Micro B cable
(3) 3-prong cable
*Voltage to ground is within this product's specifications. *Separate power source is also required.
DIFFERENTIAL PROBE 9322
• For up to 2 kV DC or 1 kV AC • Frequency band width up to 10MHz
AC ADAPTER 9418-15
100 to 240V AC
*Voltage input via banana terminals limited by the voltage specifications of the respective input unit.
CONNECTION CABLE SET L4940
Banana plug - banana plug, 1.5 m (4.92 ft) length, red/black each 1
EXTENSION CABLE SET L4931
Expands the length of L4930/4940, 1.5 m (4.92 ft) length
ALLIGATOR CLIP SET L4935
Attaches to the tip of the L4930/4940, CAT IV 600V, CAT III 1000V
BUS BAR CLIP SET L4936
Attaches to the tip of the L4930/4940, CAT III 600V
MAGNETIC ADAPTER SET L4937
Attaches to the tip of the L4930/4940, CAT III 1000V
GRABBER CLIP 9243
Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V
*For the MR8990 *Voltage is limited to the specifications of the input modules in use.
TEST LEAD L2200
70 cm (2.30ft) length, detachable large alligator clips or needle tips are bundled, CAT IV 600V, CAT III 1000V
NON-CONTACT AC VOLTAGE PROBE SP3000
• Supports φ1mm to 2.5mm covered wires • 10Hz to 100kHz frequency bandwidth • 5Vrms 14Vp-p rated measurement voltage
CONNECTION CORD L9217
Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length
CONVERSION ADAPTER 9199
Receiving side banana (female), output BNC (male)
CONNECTION CORD 9166
Metal BNC to clip, 1.5 m (4.92 ft) length
THERMOCOUPLE
*For reference only. Please purchase locally.
LOGIC PROBE MR9321-01
• 4 isolated channels • ON/OFF detection of AC/DC voltage • Large terminal type
LOGIC PROBE 9320-01
• 4 channels for contact voltage signals • 500ns response • Miniature terminal type
*A separate power supply (CT955x) is required in order to use a high-precision current sensor.
*Only sensors with ME15W (12-pin) terminals (-05 type) can be connected to the CT955x.
*The separately available CONVERSION CABLE CT9900 is required in order to use a sensor with a PL23 (10-pin) terminal.
AC/DC CURRENT SENSOR CT6862-05
• Wideband, high-precision pass-through sensor with wide temperature range • Evaluate solar power generation and fuel cells to measure battery charge and discharge and the secondary side of inverters
AC/DC CURRENT SENSOR CT6863-05
• Wideband, high-precision pass-through sensor with wide temperature range • Evaluate solar power generation and fuel cells to measure battery charge and discharge and the secondary side of inverters
AC/DC CURRENT PROBE CT6841-05
• Wideband, high-precision current probe for power efficiency testing • Evaluate EV/HEV battery charge and discharge efficiency • Measure inverter and power conditioner conversion efficiency
AC/DC CURRENT PROBE CT6843-05
• Wideband, high-precision current clamp sensor for power efficiency testing • Measuring the charge and discharge efficiency of EV/HEV batteries • Evaluate inverter and power conditioner efficiency
CLAMP ON SENSOR 9272-05
• Measuring AC current with low frequencies such as inverter control devices • Wide bandwidth ideal for harmonic analysis, FFT analysis and waveform monitoring
*A separate power supply (CT955x) is required in order to use a high-precision current sensor.
*Only sensors with ME15W (12-pin) terminals (-05 type) can be connected to the CT955x.
*The separately available CONVERSION CABLE CT9900 is required in order to use a sensor with a PL23 (10-pin) terminal.
AC/DC CURRENT PROBE CT6844-05
• Wideband and high-precision current probe for power efficiency testing • Evaluate EV/HEV battery charge and discharge efficiency • Measure inverter and power conditioner conversion efficiency
AC/DC CURRENT PROBE CT6845-05
• Wideband and high-precision current probe for power efficiency testing • Evaluate EV/HEV battery charge and discharge efficiency • Measure inverter and power conditioner conversion
AC/DC CURRENT PROBE CT6846-05
• High accuracy clamp sensor for evaluating against WLTC and automotive new fuel economy standards • EV/HEV battery charge and discharge efficiency testing • Inverter and power conditioner conversion efficiency evaluations
AC/DC CURRENT SENSOR CT6865-05
• Wideband, high-precision, high-accuracy pass-through current sensor • Capture current signals from switching power supplies, inverters, and power conditioners • Evaluate solar power generation and fuel cells
AC/DC CURRENT SENSOR CT6875
• High-accuracy sensor using the zero flux method and flux gate detection • Test inverter efficiency, inverter output power, reactor or transformer loss • Ideal for long-term DC measurements
AC/DC CURRENT SENSOR CT6876
• High-accuracy sensor using the zero flux method and flux gate detection • Test inverter efficiency, inverter output power, reactor or transformer loss • Ideal for long-term DC measurements
CONVERSION CABLE CT9900
Convert PL23 (10-pin) terminal to ME15W (12-pin) terminal
*A separate power supply (CT955x) is required in order to use a high-precision current sensor.
*Only sensors with ME15W (12-pin) terminals (-05 type) can be connected to the CT955x
*The separately available CONVERSION CABLE CT9900 is required in order to use a sensor with a PL23 (10-pin) terminal.
SENSOR UNIT CT9555
• Power supply for current sensor when used as standalone sensor • Use with high precision sensors to measure equipment such as high-capacity solar power conditioners and inverters
SENSOR UNIT CT9556
• Power supply for current sensors when used as standalone sensors • Use with high precision sensors to measure equipment such as high-capacity solar power conditioners and inverters
SENSOR UNIT CT9557
• Power supply for current sensors when used as standalone sensors • Output individual or single waveform from an aggregate of input waveforms • Use with high precision sensors to measure equipment such as high-capacity solar power conditioners and inverters
CONNECTION CORD L9217
Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length
*Up to 4 CURRENT UNITS 8971 can be connected to the MEMORY HiCORDER main unit, and up to 8 current sensors can be used, including those connected to the PROBE POWER UNIT Z5021.
*The separately available CONVERSION CABLE CT9901 is required in order to use a high-precision current sensor equipped with a ME15W (12-pin) terminal (-05 type) with the CURRENT UNIT 8971.
*While the CT955x is not required in order to use a sensor equipped with a PL23 (10-pin) terminal with the 8971, the CONVERSION CABLE 9318 (which comes with the 8971) is required for that setup.
CURRENT UNIT 8971
• 2 ch, measuring current • DC to 400 kHz bandwidth • Direct connectable with current sensors
CONVERSION CABLE 9318
To connect the CT6841-6846, CT6865/63/62, 9709, 9272-10 to the 8971/40/51, 38 cm (14.96 in) length
CONVERSION CABLE CT9901
ME15W (12 pin) to PL23 (10 pin) connector
- High-precision current sensor (ME15W) + CT9901 +
9318 → CURRENT UNIT 8971
- High-precision current sensor (ME15W) + CT955x + BNC cable → except CURRENT UNIT 8971
- High-precision current sensor (PL23) + 9318 → CURRENT UNIT 8971
- High-precision current sensor (PL23) + CT9900 + CT955x + BNC cable → except CURRENT UNIT 8971
*The 9318 comes with the CURRENT UNIT 8971.
CLAMP ON PROBE 3273-50
• Observe currents down to 10 mA • High S/N ratio • Ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers
CLAMP ON PROBE 3274
• High S/N ratio • Directly connect to high impedance BNC input of oscilloscope or recorder • Ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers
CLAMP ON PROBE 3275
• High S/N ratio • Directly connect to high impedance BNC input of oscilloscope or recorder • Ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers
CLAMP ON PROBE 3276
• Observe currents down to 10 mA • Ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers • High S/N ratio, high frequency
* Necessary for use the 3270 seies current probes
POWER SUPPLY 3272
• Power supply for wideband current probes for output to Memory HiCorders or oscilloscopes
POWER SUPPLY 3269
• Power supply for wideband current probes for output to Memory HiCorders or oscilloscopes
*For commercial power lines, 50/60 Hz
CLAMP ON LEAK HiTESTER 3283
• AC leak current and load current testing • 10 mA leak current range with 10 µA resolution
OUTPUT CORD L9094
φ 3.5 mm (0.14 in) dia. mini plug to banana, 1.5 m (4.92 ft) length
OUTPUT CORD L9095
Connect to BNC terminal, 1.5 m (4.92 ft) length
OUTPUT CORD L9096
Connect to terminal block, 1.5 m (4.92 ft) length
CONVERSION ADAPTER 9199
Receiving side banana (female), output BNC (male)
AC ADAPTER 9445-02
For USA, 100 to 240 V AC, 9 V/ 1 A
AC ADAPTER 9445-03
For EU, 100 to 240 V AC, 9 V/ 1 A
WAVE PROCESSOR 9335
• For the Memory HiCorder • Convert data, print and display waveforms
LAN CABLE 9642
Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m (16.41 ft) length
GENNECT ONE SF4000
• Automatically pair with LAN-connected measuring instruments • Display acquired data graphically in real-time • Windows compatible
CARRYING CASE C1010
For the MR6000, hard trunk type, for storing options
No results were found.