MEMORY HiCORDER

MR6000

Highest Measurement Capabilities and Fastest Transfer Rate in History

The MR6000 overcomes all barriers to reach new ground and meet challenges that are yet to be seen. World class specifications, operability and design - Hioki’s newest memory recorder has been re-engineered from top to bottom, delivering unprecedented performance that will change how you look at waveform recording. Key Features • Work efficiently and intuitively using the MR6000’s large touch panel • Capture momentary phenomena by performing isolation measurement at up to 200 MS/s (when using the High Speed Analog Unit U8976) • Enjoy a stress-free user experience thanks to dramatically faster saving of data • Save data in real time while measurement continues. • Take advantage of new functionality added by the latest firmware update (April 2020)

Model No. (Order Code)

MR6000 Main unit only, input modules up to 8 units
MR6000-01 Built-in real-time waveform calculation and other functionality

FREQUENTLY ASKED QUESTIONS Note: Main unit MR6000/MR6000-01 cannot operate alone. You must install one or more optional input modules in the unit.

GOOD DESIGN
Guarantee3years
LAN
SD
CE
USB3.0
SDHC

Firmware updates deliver enhanced ease of use in a broad range of applications

• The April 2020 update added new functionality. NEW:CAN/CAN FD measurement function NEW:Dual sampling function NEW:XY composite waveform function NEW:Waveform calculation function (period) • The February 2019 update added support for new units. NEW:3CH CURRENT UNIT U8977 NEW:4CH ANALOG UNIT U8978 NEW:CHARGE UNIT U8979 For more information, please check the MR6000 catalog.


Catalog: MEMORY HiCORDER MR6000

Hioki MR6000 Memory HiCorder - Change the Way You Measure, Record and Analyze

The MR6000’s 12.1-inch capacitive touch panel facilitates smooth, intuitive operation by allowing you to select settings simply by tapping them and to zoom in on waveforms with standard finger gestures. Moreover, the Waveform Search function makes it easy to search large volumes of measurement data for the waveforms you wish to view. The instrument can also automatically search all measured data for anomalous waveforms.


High-speed isolated measurement at 200 MS/s

The High Speed Analog Unit U8976 boasts the highest sampling rate in its entire series, an order of magnitude faster than conventional models, enabling the unit to perform isolated measurement at 200 MS/s. Thanks to its overwhelmingly fast sampling speeds, the unit can accurately acquire changes in high-speed signals so that you can capture momentary phenomena.


Frequency band and isolated performance that let you accurately capture high switching frequencies

The MR6000 provides isolated channels that can accept 400 V DC direct input while maintaining high-speed sampling at 200 MS/s, allowing it to accurately capture switching waveforms in evaluation testing of inverter and power supply designs that are required to deliver high levels of efficiency. Smooth operation lets you read trace values simply by flicking the flicking the cursor to the side.


Completely isolated input

Connections between analog input channels, and between the input channel and the main unit, are fully isolated. This means that, unlike an oscilloscope, measurements can be made without concern with negative effects from potential differences. << Optical isolation devices (HIGH SPEED ANALOG UNIT U8976) 


Save Time Reduced to 1/30th

Transferring very large amounts of data measured over a long period of time used to be very time-consuming. The MR6000 features a brand new interface and faster internal processing, reducing the time required to save measurement data to media. For example, a save operation that took 1 minute on the previous model now completes in 2 seconds. This saves you the trouble of waiting for data to be saved and improves work efficiency.


Long-term recording and high-speed sampling in multiple channels

The real-time save function controls the available measurement duration without relying on the capacity of the internal memory. For long-term recording, we recommend a high-capacity SSD or HD unit. You can also use a more convenient USB memory stick or SD memory card. All phenomena can be recorded at a high sampling rate over a long period of time. 《Saving data directly to your PC》 Transfer measurement data directly to your PC by using the FTP sending function together with the real-time save function. This makes it easier to observe data after the measuring process.


An Extensive Line of Units for Detecting a Wide Range of Phenomena

Combine multiple units to record a range of phenomena. Use multiple logic units to measure relay ON/OFF signals or PLC (programmable logic controller) signals across up to 128 channels simultaneously. You can also measure temperature by attaching a thermocouple to a temperature unit. 《Unit selection guide》 HIGH SPEED ANALOG UNIT U8976 ANALOG UNIT 8966 4CH ANALOG UNIT U8975 4CH ANALOG UNIT U8978 HIGH RESOLUTION UNIT 8968 DC/RMS UNIT 8972 HIGH VOLTAGE UNIT U8974 DIGITAL VOLTMETER UNIT MR8990 3CH CURRENT UNIT U8977 CURRENT UNIT 8971 TEMP UNIT 8967 STRAIN UNIT U8969 FREQ UNIT 8970 CHARGE UNIT U8979 LOGIC UNIT 8973 See the “Options” tab of the MR6000 webpage for more information about units.


High-sensitivity, high-precision, broadband current probes and sensors

《Current probe》 Analyze minuscule current waveforms from low-power consumption devices in 100 μA resolution. Record device current consumption waveforms in high resolution over extended periods of time. Additionally, the optional Probe Power Unit Z5021 can supply power to current probes from the MR6000. 《Current sensor》 Clamp-type high-accuracy sensors deliver excellent temperature characteristics, allowing highly accurate measurements to be made even in the confined space of a vehicle’s engine compartment. The 3ch Current Unit U8977 lets you connect current sensors directly, allowing the MR6000 to power them and scale readings automatically.


[Since Ver. 3] CAN/CAN FD Measurement

CAN buses carry not only control information, but also sensor information required by the ECU for control purposes. Analog values for sensor input signal quantities such as voltage, strain, temperature, flow rate, RPM, torque, vehicle speed, and vibration can be measured at the same time as these signals. 《Capture all data on the CAN bus during measurement》 The MR6000 captures all frame data on the CAN or CAN FD bus during the set recording time. After measurement, you can specify the signals you wish to check and display them on the screen.


Calculate measurement data during measurement (Real-time waveform processing) *MR6000-01 feature

The MR6000-01 further features powerful technology designed for robust real-time waveform processing. This function performs the four arithmetic operations (addition, subtraction, multiplication, and division), differentiation calculations, or integration calculations during the measuring process, letting you use check the calculated results via waveforms while measuring or apply triggers during monitoring. Results can be further processed after measurement and saved.


Observe clear waveforms without noise (Digital filter calculations) *MR6000-01 feature

Remove harmonic noise or specific frequency noise from measurement data. Use it to eliminate the noise that cannot be resolved with the standard filter installed in the unit.


Triggers that detect targeted events

Set triggers on any channel to record data whenever an event occurs. Triggers can be set for all channels. Level trigger : Compares to one voltage value. Window trigger : Compares to two voltage values. Voltage drop trigger : Detects voltage drops in commercial power lines. Period trigger : Monitors periods. Glitch trigger : Detects anomalies in pulses. Pattern trigger : Compares when the logic signal is ON/OFF.


Observe fluctuations for extended periods of time without reducing the sampling rate (Envelope function)

The system uses the envelope measurement method to record maximum and minimum values at set intervals while performing oversampling at 100 MS/s. The internal memory has a capacity of 1 G-words, which ensures that the measuring process can continue for a long time without any data loss. Save data in real time while measuring.


[Since Ver. 3] Measure anomalies during extended testing with high-speed sampling (Dual sampling function)

In vibration testing, it's necessary to record comprehensive test data for several hours. At the same time, it’s necessary to capture areas of the waveform where anomalies occur with high-speed sampling for analysis once measurement is complete. The dual sampling function is useful in such situations. (1) Record the entire trend waveform Use the envelope function to record comprehensive test data for several hours. (2) Check details with the instantaneous waveform Anomalies occurring during the test will be captured with high-speed sampling based on triggers that have been set up in advance. By tapping on a trigger mark’s number, you can display the instantaneous waveform for the anomaly that occurred at that waveform area.


Display Functions

《Scroll function》 You can use the scroll function to check the waveform as if viewing it on paper. 《Zoom function》 The zoom function allows you to display all measurement waveforms on a single screen, in the manner of an oscilloscope, and to view desired locations in greater detail. 《Sheet function (display group)》 Switch among 16 sheets to analyze the waveform from various perspectives.


Easily search for waveforms in huge volumes of measurement data

The Memory HiCorder Concierge function automatically calculates the characteristics of a reference waveform set by the customer and then searches all measured data while identifying waveforms that do not resemble the reference waveform as anomalous waveforms. This drastically reduces the amount of time required to search for anomalies by eliminating the need to scroll through measured waveforms and checking them visually. Additionally, this function is ideal for situations where it is difficult to set the right triggers before measuring because the nature of potential anomalies cannot be predicted.


Numerical calculation function

By performing numerical calculations on measured waveforms, you can perform analyses using numerical parameters. Not only analog channels and logic channels, but also results of the real-time waveform calculation function can be used in this calculations. 《Calculating switching times measured using logic channels (t1, t2, t3, T) 》 You can calculate time differences by applying numerical calculations to signals measured using logic channels. 《Calculating the time that elapses until a reading falls from the maximum value to a defined level (50 V) after a capacitor is charged during capacitor charge/discharge testing》 You can calculate the desired value by calculating the time at which the maximum value occurs and the time at which the specified level occurs using numerical calculations and then performing your desired arithmetic operations. 《Calculating the motor inrush starting current time (t1) 》 You can derive the desired time by calculating the burst width using numerical calculations.


[Since Ver. 3] Applications

《Power Fluctuation Measurement》 Please check the MR6000 catalog. 《Motor Torque and Vibration Measurement》 Please check the MR6000 catalog. 《Measurement of Dynamic Motor Characteristics》 Please check the MR6000 catalog. 《Calculate a Resolver’s Angle of Rotation》 https://www.hioki.com/en/products/introduction/detail/?dbid=113479


PC Software 《MR6000 Viewer》

Load data measured with the MR6000/MR6000-01 onto a PC to display waveforms and perform calculations. Utilize functionality similar to that provided by the MR6000 on a PC, including numerical calculations, waveform processing, and FFT calculations. (Some restrictions apply.)


> Download the MR6000 Viewer

Design

Our search for a touch screen with the best operability and visibility angle led us to develop retractable feet that maximize those two important attributes. Tilting the MR6000 with the feet reduces the strain on your wrists when you use the device on a desk, and keeps your line of sight at a natural level. The beveled corners of the Memory HiCorder’s body gives the device a compact and sleek look. This simple and refined appearance is sure to be a strong addition to the creative environment of any R&D workspace.


Design accolades

《2018 iF Design Award》 The MR6000 received an iF Design Award from Industrie Forum Design Hannover, an international organization that promotes design. 《2018 Japan Manual Contest》 The MR6000 and MR6000-01 Memory HiCorder’s Quick Start Manual received an Excellence Award in the industry category of the Japan Manual Contest. 《2018 Good Design Award》 One judge observed, “The MR6000’s design has been tweaked so that the product, which was originally designed for use in maintenance settings, can also be used in the development of inverter and power conditioner technologies to improve the energy efficiency of these continually evolving devices. Refined to detect the effects of minuscule changes, the product is praiseworthy for balancing research-oriented functionality and user friendliness while significantly boosting measurement precision. Its features include isolated channels, a readily portable design, accommodation of extended measurement time as evident in design touches like the ergonomic angle of its monitor and use of a touch panel, and an interface that allows users to view multiple phenomena at once. Through all of these, one can see the designer’s thoughtfulness towards both the maintenance and R&D engineer.


> Learn more about iF Design Awards (external link)

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

MR6000MR6000-01
Additional functionN/AReal-time waveform calculation, Digital Filter calculation
Number of input unitsMax. 8 units
Number of channelsMax. 32 analog channels (when using the U8975), or 128 logic channels (when using the 8973)
Measurement ranges (20 div full-scale)10 mV to 400 V f.s., 12 ranges (when using the U8976), Resolution : 1/1600 of range
4 V to 200 V f.s., 6 ranges (when using the U8975), Resolution : 1/32000 of range
Max. allowable input400 V DC (when using the U8976), 200 V DC (when using the U8975)
Frequency characteristicsDC to 30 MHz (when using the U8976), DC to 2 MHz (when using the U8975)
Max. sampling rate200 MS/s, all channnels simultaneously (when using the U8976)
External sampling: 10 MS/s
Recording methodsNormal: Normal waveform recording
Envelope: Record maximum and minimum values every fixed period
Storage memory capacity1 G-words
Removable storageSD memory card ×1, USB memory ×7, SSD/HDD (built in the main unit) ×1
FTP transmission (to LAN-connected computer) *Use only Storage Media sold by HIOKI.
Display12.1 inch XGA-TFT color LCD (1024 × 768 dots)
External interfacesLAN, USB, SD, SATA, Monitor output
Power supply100 to 240 V AC (50/60 Hz) (300 VA max.)
Dimensions and mass353 mm (13.9 in)W × 235 mm (9.25 in)H × 154.8 mm (6.09 in)D, 6.5 kg (229.3 oz) (main unit only)
AccessoriesPower cord ×1, Quick start manual ×1, Precautions conserning use ×1, Application disk (CD-R) ×1, Instruction manual (CD-R, detail and calculation) ×1 , Blank panel (for blank slots only)

Log into your myHioki account to access more technical documents and information where available.

Seminar Videos On Demand

No results were found.

Seminar Schedule

No results were found.

Catalogs

Catalog: HIGH ACCURACY / WIDEBAND CURRENT SENSOR Series CT686x, CT687x, CT684x Download PDF  [8MB] English
Catalog: MEMORY HiCORDER MR6000 Download PDF  [6MB] English
Catalog: GENNECT ONE SF4000 Download PDF  [1MB] English
Preview Catalog: MR6000 Viewer Download PDF  [945KB] English
Catalog: Motor Measurement Applications Download PDF  [4MB] English

User Guides

No results were found.

Manuals

If you can not download, log into your myHioki account to access more technical documents and information where available.


MR6000-01 Dedicated Functions English
Ver.01
MR6000-01 Dedicated Functions Simplified Chinese
Ver.00
Quick Start Manual English
Ver.02
Instruction Manual English
Ver.02
Quick Start Manual Simplified Chinese
Ver.01
Instruction Manual Simplified Chinese
Ver.01

Outline Drawings

If you can not download, log into your myHioki account to access more technical documents and information where available.



Ver.02

Ver.02

Ver.02

Ver.02

Declaration of Conformity


Ver.01

Others

No results were found.

Options

Factory-installed option A

*Must specify when ordering

*Power can be supplied to up to 8 current sensors, including the current sensors connected to the CURRENT UNIT 8971.

PROBE POWER UNIT Z5021

Specified upon order of the MR6000, power max. 4 × CT6710 series, or max. 8 × other probes

Factory-installed option B

*Must specify when ordering

SSD UNIT U8332

Specified upon order, built-in type, 256 GB

Factory-installed option C

*Must specify when ordering

HD UNIT U8333

Specified upon order, built-in type, 320 GB

Storage media

*Precaution

*Use only the storage media sold by HIOKI. Compatibility and performance are not guaranteed for storage media made by other manufacturers. You may be unable to read from or save data to such media.

SD MEMORY CARD 2GB Z4001

2 GB capacity

SD MEMORY CARD Z4003

8 GB capacity

USB DRIVE Z4006

16 GB, Long-life, High-reliability SLC Flash Memory

Input modules

*Input cords not included. Please purchase separately.

*When using 9709 with CURRENT UNIT 8971, a total of 7 current probes can be used.

HIGH SPEED ANALOG UNIT U8976

・ 2 ch ・ DC to 30 MHz bandwidth

Learn more

4CH ANALOG UNIT U8975

・ 4 ch ・ DC to 2 MHz bandwidth

Learn more

HIGH VOLTAGE UNIT U8974

・ 2 ch, High-voltage input ・ Max. 1000 VDC, 700 VAC rms ・ DC to 100 kHz bandwidth

Learn more

ANALOG UNIT 8966

• 2 ch, instantly waveforms • DC to 5 MHz bandwidth

Learn more

HIGH RESOLUTION UNIT 8968

• 2 ch, high resolution measurement • DC to 100 kHz bandwidth

Learn more

DC/RMS UNIT 8972

• 2 ch, instantly waveform/RMS • DC to 400 kHz bandwidth • RMS: DC and 30 to 100 kHz

Learn more

CURRENT UNIT 8971

• 2 ch, measuring current • DC to 100 kHz bandwidth • Directly connectable with current sensors

Learn more

DIGITAL VOLTMETER UNIT MR8990

・ For minute voltage measurement ・ Max. 0.1 μV resolution ・ 500 times/s sampling

Learn more

TEMP UNIT 8967

• 2 ch, Temperature • Thermocouple input

Learn more

STRAIN UNIT U8969

• 2 ch, acceleration, load, pressure or strain • Strain gauge converter amp

Learn more

FREQ UNIT 8970

• 2 ch, Rotation, Frequency • DC to 100 kHz

Learn more

LOGIC UNIT 8973

• 16 ch, logic signal • up to four logic probes

Learn more

3CH CURRENT UNIT U8977

・ 3 ch, current measurement ・ DC to 2 MHz bandwidth

Learn more

4CH ANALOG UNIT U8978

・ 4 ch instantaneous waveforms ・ DC to 2 MHz bandwidth

Learn more

CHARGE UNIT U8979

・ Measure acceleration waveforms across 2 channels ・ Charge output type acceleration pickup ・ Preamplifier built-in acceleration pickup

Learn more

External sampling measurement

CONNECTION CABLE L9795-01

Max. rated voltage to earth: 33 Vrms AC or 70 V DC, SMB to alligator clip, 1.5 m (4.92 ft) length

CONNECTION CABLE L9795-02

Max. rated voltage to earth: 33 Vrms AC or 70 V DC, SMB to BNC terminal, 1.5 m (4.92 ft) length

INPUT CORD (A)

*Voltage is limited to the specifications of the input modules in use.

CONNECTION CORD L9790

• Flexible φ 4.1 mm (0.16 in) thin dia. • Cable allowing for up to 600 V input • 1.8 m (5.91 ft) length

ALLIGATOR CLIP L9790-01

Red/black set attaches to the ends of the Connection Cord L9790

GRABBER CLIP 9790-02

Red/black set attaches to the ends of the Connection Cord L9790

CONTACT PIN 9790-03

Red/black set attaches to the ends of the Connection Cord L9790

INPUT CORD (B)

*Voltage is limited to the specifications of the input modules in use.

CONNECTION CORD L9198

•φ 5.0 mm (0.20 in) dia. •Cable allows for up to 300 V input •1.7 m (5.58 ft) length •Small alligator clip

CONNECTION CORD L9197

•φ 5.0 mm (0.20 in) dia •Cable allows for up to 600 V input •1.8 m (5.91 ft) length •Includes detachable large alligator clips

GRABBER CLIP 9243

Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V

INPUT CORD (C)

*Voltage is limited to the specifications of the input modules in use.

10:1PROBE 9665

・1 kV rms Max. (500 kHz or less) ・Max. rated voltage to earth depends on input unit.

Learn more

100:1PROBE 9666

・5 kV peak Max. (1 MHz or less) ・Max. rated voltage to earth depends on input unit.

Learn more

INPUT CORD (D)

*Voltage to ground is within this product's specifications. *Separate power source is also required.

DIFFERENTIAL PROBE P9000

• Waveform only for exclusive use with Memory HiCorders (P9000-01) or waveform/RMS value switchable (P9000-02) • For use with input of up to 1 kV AC/DC • Requires separate power supply

Learn more

AC ADAPTER Z1008

100 to 240V AC

Custom cable For P9000. Inquire with your local Hioki distributor.

(1) Bus powered USB cable
(2) USB(A)- Micro B cable
(3) 3-prong cable

INPUT CORD (E)

*Voltage to ground is within this product's specifications. *Separate power source is also required.

DIFFERENTIAL PROBE 9322

• For up to 2 kV DC or 1 kV AC • Frequency bandwidth up to 10MHz

Learn more

AC ADAPTER 9418-15

100 to 240V AC

INPUT CORD (F)

*Voltage input via banana terminals limited by the voltage specifications of the respective input unit.

CONNECTION CABLE SET L4940

Banana plug - banana plug, 1.5 m (4.92 ft) length, red/black each 1

EXTENSION CABLE SET L4931

Expands the length of L4930/4940, 1.5 m (4.92 ft) length

ALLIGATOR CLIP SET L4935

Attaches to the tip of the L4930/4940, CAT IV 600 V, CAT III 1000 V

BUS BAR CLIP SET L4936

Attaches to the tip of the L4930/4940, CAT III 600 V

MAGNETIC ADAPTER SET L4937

Attaches to the tip of the L4930/4940, CAT III 1000 V

GRABBER CLIP 9243

Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V

INPUT CORD (G)

*For the MR8990 *Voltage is limited to the specifications of the input modules in use.

TEST LEAD L2200

70 cm (2.30ft) length, detachable large alligator clips or needle tips are bundled, CAT IV 600V, CAT III 1000V

Non-contact voltage measuring

NON-CONTACT AC VOLTAGE PROBE SP3000

• Supports φ1mm to 2.5mm covered wires • 10Hz to 100kHz frequency bandwidth • 5Vrms 14Vp-p rated measurement voltage

Learn more

Other options for input

CONNECTION CORD L9217

Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length

CONVERSION ADAPTER 9199

Receiving side banana (female), output BNC (male)

CONNECTION CORD 9166

Metal BNC to clip, 1.5 m (4.92 ft) length

Temperature sensor

THERMOCOUPLE
*For reference only. Please purchase locally.

Logic signal measurement

LOGIC PROBE 9327

• 4 channels for contact voltage signals • High-speed 100ns response

Learn more

LOGIC PROBE MR9321-01

• 4 isolated channels • ON/OFF detection of AC/DC voltage • Large terminal type

Learn more

LOGIC PROBE 9320-01

• 4 channels for contact voltage signals • 500ns response • Miniature terminal type

Learn more

Up to 200 A (High precision)

*A separate power supply (CT955x) is required in order to use a high-precision current sensor.

*Only sensors with ME15W (12-pin) terminals (-05 type) can be connected to the CT955x.
*The separately available CONVERSION CABLE CT9900 is required in order to use a sensor with a PL23 (10-pin) terminal.

AC/DC CURRENT SENSOR CT6862-05

• DC to 1MHz, ±0.05% accuracy • Rated 50A AC/DC

Learn more

AC/DC CURRENT SENSOR CT6863-05

• DC to 500kHz, ±0.05% accuracy • Rated 200A AC/DC

Learn more

AC/DC CURRENT PROBE CT6841-05

• DC to 1MHz, ±0.3% accuracy • Rated 20A AC/DC

Learn more

AC/DC CURRENT PROBE CT6843-05

• DC to 500kHz, ±0.3% accuracy • Rated 200A AC/DC

Learn more

CLAMP ON SENSOR 9272-05

• 1Hz to 100kHz, ±0.3% accuracy • Rated 20A/200A AC/DC

Learn more

Up to 1000 A (High precision)

*A separate power supply (CT955x) is required in order to use a high-precision current sensor.

*Only sensors with ME15W (12-pin) terminals (-05 type) can be connected to the CT955x.
*The separately available CONVERSION CABLE CT9900 is required in order to use a sensor with a PL23 (10-pin) terminal.

AC/DC CURRENT PROBE CT6844-05

• DC to 200kHz, ±0.3% accuracy • Rated 500A AC/DC

Learn more

AC/DC CURRENT PROBE CT6845-05

• DC to 100kHz, ±0.3% accuracy • Rated 500 A AC/DC

Learn more

AC/DC CURRENT PROBE CT6846-05

• DC to 20kHz, ±0.3% accuracy • Rated 1000A AC/DC

Learn more

AC/DC CURRENT SENSOR CT6875

• DC to 2MHz, ±0.04% accuracy • Rated 500A AC/DC

Learn more

AC/DC CURRENT SENSOR CT6876

• DC to 1.5MHz, ±0.04% accuracy • Rated 1000A AC/DC

Learn more

PL23 (10-pin) - ME15W (12-pin) conversion

CONVERSION CABLE CT9900

Convert PL23 (10-pin) terminal to ME15W (12-pin) terminal

POWER SUPPLY for Current Sensors

*A separate power supply (CT955x) is required in order to use a high-precision current sensor.

*Only sensors with ME15W (12-pin) terminals (-05 type) can be connected to the CT955x
*The separately available CONVERSION CABLE CT9900 is required in order to use a sensor with a PL23 (10-pin) terminal.

SENSOR UNIT CT9555

• 1 channel • Waveform output

Learn more

SENSOR UNIT CT9556

• 1 channel, ±0.2% DC accuracy • Waveform and RMS output

Learn more

SENSOR UNIT CT9557

• 4 channels, ±0.06% DC accuracy • Waveform, total waveform, and total RMS output

Learn more

CONNECTION CORD L9217

Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length

Directly connectable with the Current Sensor

*Up to 4 CURRENT UNITS 8971 can be connected to the MEMORY HiCORDER main unit, and up to 8 current sensors can be used, including those connected to the PROBE POWER UNIT Z5021.

*The separately available CONVERSION CABLE CT9901 is required in order to use a high-precision current sensor equipped with a ME15W (12-pin) terminal (-05 type) with the CURRENT UNIT 8971.
*While the CT955x is not required in order to use a sensor equipped with a PL23 (10-pin) terminal with the 8971, the CONVERSION CABLE 9318 (which comes with the 8971) is required for that setup.

CURRENT UNIT 8971

• 2 ch, measuring current • DC to 100 kHz bandwidth • Directly connectable with current sensors

Learn more

CONVERSION CABLE 9318

To connect the CT6841-6846, CT6865/63/62, 9709, 9272-10 to the 8971/40/51, 38 cm (14.96 in) length

CONVERSION CABLE CT9901

ME15W (12 pin) to PL23 (10 pin) connector

Precautions for connecting high-precision current sensors

- High-precision current sensor (ME15W) + CT9901 +
9318 → CURRENT UNIT 8971
- High-precision current sensor (ME15W) + CT955x + BNC cable → except CURRENT UNIT 8971
- High-precision current sensor (PL23) + 9318 → CURRENT UNIT 8971
- High-precision current sensor (PL23) + CT9900 + CT955x + BNC cable → except CURRENT UNIT 8971
*The 9318 comes with the CURRENT UNIT 8971.

10 mA class to 500 A (High speed)

CLAMP ON PROBE 3273-50

• DC to 50MHz (−3dB), ±1.0% accuracy • Maximum 30 A rms • ±50 A peak (non-continuous)

Learn more

CLAMP ON PROBE 3274

• DC to 10MHz (−3dB), ±1.0% accuracy • Maximum 150 A rms • ±300 A peak (non-continuous)

Learn more

CLAMP ON PROBE 3275

• DC to 2MHz (−3dB), ±1.0% accuracy • Maximum 500 A rms • ±700 A peak (non-continuous)

Learn more

CLAMP ON PROBE 3276

• DC to 100 MHz (−3dB), ±1.0% accuracy • Maximum 30 A rms • ±50 A peak (non-continuous)

Learn more

Power supply

* Necessary for use the 3270 seies current probes

POWER SUPPLY 3272

• 1 or 2 channels for CT6700 and 3270 series • ±12 V output

Learn more

POWER SUPPLY 3269

• 2 channels for CT6710 series or 4 channels for CT6700 and 3270 series • ±12 V output

Learn more

Leak Current

*For commercial power lines, 50/60 Hz

CLAMP ON LEAK HiTESTER 3283

• 10 mA to 200 A AC for leak to load current testing • 10 mA leak current range with 10 µA resolution

Learn more

OUTPUT CORD L9094

φ 3.5 mm (0.14 in) dia. mini plug to banana, 1.5 m (4.92 ft) length

OUTPUT CORD L9095

Connect to BNC terminal, 1.5 m (4.92 ft) length

OUTPUT CORD L9096

Connect to terminal block, 1.5 m (4.92 ft) length

CONVERSION ADAPTER 9199

Receiving side banana (female), output BNC (male)

AC ADAPTER 9445-02

For USA, 100 to 240 V AC, 9 V/ 1 A

AC ADAPTER 9445-03

For EU, 100 to 240 V AC, 9 V/ 1 A

PC Software

FlexPro

• Third party software • For detailed analysis of Memory HiCorder data

Learn more

WAVE PROCESSOR 9335

• For the Memory HiCorder • Convert data, print and display waveforms

Learn more

LAN CABLE 9642

Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m (16.41 ft) length

GENNECT ONE SF4000

• Automatically pair with LAN-connected measuring instruments • Display acquired data graphically in real-time • Windows compatible

Learn more

Case

CARRYING CASE C1010

For the MR6000, hard trunk type, for storing options

Gallery

No results were found.


  • Search


    Search Results Include Discontinued Products

    Login to myHIOKI

    Download

  • Ask

    • Ask Online

     

  • Quote

    • Request a Quote
    • Locate a Distributor

Related Products List