POWER QUALITY ANALYZER
PQ3100
3-Phase 4-Wire Power Quality Analyzer Compliant to IEC61000-4-30 Class S Standards and On-screen Guide to Deliver Easy Setup and Testing
Hioki portable power meters and analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy. The PQ3100 is a comprehensive but easy-to-use power quality analyzer for monitoring and recording power supply anomalies, allowing their causes to be quickly investigated, and also for assessing power supply problems such as voltage drops, flicker, harmonics, and other electrical issues. Key Features • Record data including voltage, current, power, harmonics, and flicker simultaneously along a single time axis • Measure up to 6000 A AC • Capture all power anomalies, including instantaneous outages, voltage drops, and frequency fluctuations, while simultaneously recording trend data • Quick Set: Easy-to-understand on-screen guide for measurement procedures • Bundled PQ ONE application software makes it easy to create reports • Record waveforms for up to 1 second before and 10 seconds after an anomaly occurs • Accurately measure DC currents over extended periods of time (with an AC/DC auto-zero current sensor) • Directly supply power to connected current sensors • Send measured values to HIOKI data loggers using a Bluetooth® wireless technology compatible adapter (LR8410 Link-compatible products), Ver. 2.0 and later Have questions? Need a Quote? Contact us.
PQ3100 | Main unit, current sensor is sold separately |
---|---|
PQ3100-91 | Kit includes 600 A sensor × 2 and other options |
PQ3100-92 | Kit includes 600 A sensor × 4 and other options |
PQ3100-94 | Kit includes 6000 A sensor × 4 and other options |
FREQUENTLY ASKED QUESTIONS Note: An optional current sensor is necessary to measure current or power parameters. Select from Value Kits for added savings.
The Hioki PQ3100 Power Quality Analyzer measures all power parameters including voltage, current, power, harmonics, and flicker simultaneously along the same time axis, giving it the ability to capture all power anomalies such as intermittent power interruptions, voltage drops and frequency fluctuations while recording the power trend.
The Hioki PQ3100 Power Quality Analyzer provides an intuitive QUICK SET navigation system to simplify the wiring and configuration procedures for measuring a 3-phase system. Connection mistakes such as reversing the direction of the clamp sensor or phase order are automatically detected along with suggestions on how to correct the setup.
The free PQ ONE application software for the PQ3100 Power Quality Analyzer lets you analyze captured data in fine detail and create regular power quality management reports with ease and flexibility. Investigate the cause of power anomalies in the comfort of your office using your PC.
Capture data on the PC while testing remotely
Measurement line type | Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra input channel CH4 for voltage/current, (all channels AC/DC measurement) |
---|---|
Voltage ranges | Voltage measurement: 1000.0 V rms or DC, Transient measurement 2.200 kV peak |
Current ranges | 50.000 mA AC to 5.0000 kA AC, 10.000 A DC to 2.0000 kA DC (depends on current sensor in use) |
Power ranges | 50.000 W to 6.0000 MW (determined automatically based on current range in use) |
Basic accuracy | Voltage: ±0.2% of nominal voltage, Current: ±0.1 % rdg. ±0.1 % f.s. + current sensor accuracy, Active power: DC ±0.5 % rdg. ±0.5 % f.s. + current sensor accuracy, AC ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy |
Measurement items | 1. Transient over voltage : 200 kHz sampling 2. Frequency cycle : Calculated as one cycle 3. Voltage (1/2) RMS, Current (1/2) RMS: one cycle calculation refreshed every half cycle 4. Voltage swell, Voltage dips, Voltage interruption, RVC (Ver.2.0 or later) : Voltage (1/2) RMS calculation 5. Inrush current : half-cycle calculation: Calculated as the current RMS value for current waveform data sampled every half-cycle. 6. Frequency 200 ms: Calculated as 10 or 12 cycles 7. 10-sec frequency: Calculated as the whole-cycle time during the specified 10 s period 8. Voltage waveform peak, Current waveform peak 9. Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Apparent energy, Reactive energy, Energy cost, Power factor, Displacement power factor, Voltage unbalance factor, Current unbalance factor 10. Voltage crest factor, Current crest factor 11. Harmonic/ Harmonic phase angle (voltage/ current), Harmonic power: 0 th to 50 th orders 12. Harmonic voltage-current phase angle: 1 th to 50 th orders 13. Total harmonic distortion factor (voltage/ current) 14. Inter harmonic (voltage/ current): 0.5 th to 49.5 th orders 15. K Factor (multiplication factor) 16. IEC Flicker, Δ V10 Flicker |
Record | Maximum recording interval: 1 year, Maximum number of recordable events: 9999 × 365 days |
Interfaces | SD/SDHC memory card, RS-232C (for communication/ LR8410 link), LAN (HTTP server/ FTP/ Send e-mail), USB 2.0 (for communication) |
Logger connectivity | Sends measured values wirelessly to logger by using a Bluetooth® wireless technology serial conversion adapter. (Supported devices: Hioki LR8410 Link-compatible loggers), Ver. 2.0 and later |
Display | 6.5-inch TFT color LCD (640 × 480 dots) |
Power supply | AC adapter Z1002 (100 V to 240 V AC, 50/60 Hz, rated current 1.7 A), Battery pack Z1003 (Continuous use: 8 hr, Charging time: Max. 5 hr 30 m with AC adapter) |
Dimensions and mass | 300 mm (11.81 in)W × 211 mm (8.31 in)H × 68 mm (2.68 in)D, 2.5 kg (88.2 oz) (including battery pack) |
Accessories | Instruction manual ×1, Measurement guide ×1, Voltage cord L1000-05 ×1 set (Red/Yellow/Blue/Gray/Black, Alligator clip ×5, Spiral tube ×5), Color clip (for identifying clamp sensor color) ×1 set, Spiral tube ×5, AC adapter Z1002 ×1, Strap ×1, USB cable (1 m 3.28 ft length) ×1, Battery pack Z1003 ×1, PQ ONE (software, CD) ×1 |
Log into your myHioki account to access more technical documents and information where available.
No results were found. |
No results were found. |
Flyer Catalog: LR8410 Link | Download PDF [1MB] |
English |
Catalog: ANALIZADOR DE CALIDAD DE LA ENERGÍA PQ3100 | Download PDF [4MB] |
Spanish |
Catalog: GENNECT ONE SF4000 | Download PDF [4MB] |
English |
Catalog: POWER QUALITY ANALYZER PQ3198, PQ3100 | Download PDF [6MB] |
English |
Guidebook for Power Quality Measurement | Download PDF [4MB] |
English |
Voltage, Current, and Power Measurement for Cycle-controlled Loads, Phase-controlled Loads, and Inverters | Download PDF [558KB] |
English |
If you can not download, log into your myHioki account to access more technical documents and information where available.
Measurement Guide |
Simplified Chinese |
Ver.01 | |
Measurement Guide |
Korean |
Ver.01 | |
Measurement Guide |
English |
Ver.01 | |
Measurement Guide |
Spanish |
Ver.00 | |
Measurement Guide |
Indonesian |
Ver.00 | |
POWER QUALITY ANALYZER PQ3100 [8MB] |
Instruction Manual |
English |
Ver.03 |
POWER QUALITY ANALYZER PQ3100 [8MB] |
Instruction Manual |
Korean |
Ver.01 |
POWER QUALITY ANALYZER PQ3100 [7MB] |
Instruction Manual |
Spanish |
Ver.01 |
POWER QUALITY ANALYZER PQ3100 [20MB] |
Instruction Manual |
Simplified Chinese |
Ver.01 |
If you can not download, log into your myHioki account to access more technical documents and information where available.
POWER QUALITY ANALYZER PQ3100 [167KB] |
Ver.00 |
POWER QUALITY ANALYZER PQ3100 [161KB] |
Ver.01 |
POWER QUALITY ANALYZER PQ3100 | Firmware | V2.30 |
PQ ONE | Freeware | V8.00 |
GENNECT One | Freeware | V4.11 |
Flyer: Usable temperature range Max.65°C Max.-25°C | Download PDF [1MB] |
English |
For power or load current measurement (1 sensor necessary for single-phase measurements, and 2 or 3 sensors required for 3-phase measurements)
AC CURRENT SENSOR CT7126
60 A AC, φ 15 mm (0.59 in), 2.5 m (8.20 ft) cord length
AC CURRENT SENSOR CT7131
100 A AC, φ 15 mm (0.59 in), 2.5 m (8.20 ft) cord length
AC FLEXIBLE CURRENT SENSOR CT7040 series
• 10 Hz to 50 kHz, ±1.5% accuracy • 600A or 6000A AC rated
AC CURRENT SENSOR CT7136
600 A AC, φ 46 mm (1.81 in), 2.5 m (8.20 ft) cord length
*For leak current measurement (not capable of power measurement)
AC LEAKAGE CURRENT SENSOR CT7116
6 A AC, φ 40 mm (1.57 in), 2.5 m (8.20 ft) cord length
EXTENSION CABLE L0220-01
2 m (6.56 ft) length
EXTENSION CABLE L0220-02
5 m (16.41 ft) length
EXTENSION CABLE L0220-03
10 m (32.81 ft) length
SD Card Precaution
Use only the SD Card Z4001 sold by HIOKI. Compatibility and performance are not guaranteed for SD cards made by other manufacturers. You may be unable to read from or save data to such cards.
SD MEMORY CARD 2GB Z4001
2 GB capacity
SD MEMORY CARD Z4003
8 GB capacity
The L1000-05 is bundled with PQ3100
*Please inquire about voltage cord extension
VOLTAGE CORD L1000-05
Red/ Yellow/ Blue/ Gray/ Black each 1, 3 m (9.84 ft) length, Alligator clip ×5
Shared options for the PQ3198 / PQ3100
PATCH CORD L1021-01
Banana branch-banana, Red: 1, 0.5 m (1.64 ft) length, for branching from the L9438s or L1000s, CAT IV 600 V, CAT III 1000 V
PATCH CORD L1021-02
Banana branch-banana, Black: 1, 0.5 m (1.64 ft) length, for branching from the L9438s or L1000s, CAT IV 600 V, CAT III 1000 V
GRABBER CLIP 9243
Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length
MAGNETIC ADAPTER 9804-01
Attaches to the tip of cord, red ×1, φ11 mm (0.43 in)
MAGNETIC ADAPTER 9804-02
Attaches to the tip of cord, black ×1, φ11 mm (0.43 in)
GRABBER CLIP L9243
Attaches to the tip of the banana plug cable, Red/Black: 1 each, 185 mm (7.28 in.) length
*The Z4001 is bundled to PQ3198 only
SD Card Precaution
Use only the SD Card sold by HIOKI. Compatibility and performance are not guaranteed for SD cards made by other manufacturers. You may be unable to read from or save data to such cards.
SD MEMORY CARD 2GB Z4001
2 GB capacity
SD MEMORY CARD Z4003
8 GB capacity
*The Z1002, Z1003 are bundled
AC ADAPTER Z1002
For main unit, 100 to 240 V AC
BATTERY PACK Z1003
NiMH, Charges while installed in the main unit
Shared options for the PQ3100 / PQ3198
GENNECT ONE SF4000
• Automatically pair with LAN-connected measuring instruments • Display acquired data graphically in real-time • Windows compatible
CONVERSION CABLE L9910
Used to connect the current sensors with BNC terminal to PL14 terminal (example the PQ3100)
RS-232C CABLE 9637
9 pin - 9 pin, cross, 1.8 m (5.91 ft) length
LAN CABLE 9642
Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m (16.41 ft) length
When using with PQ3100 / PQ3198, suspend the main body on the metal surface using two Z5020 powerful type.
Z5004 hang the cords on the metal surface.
MAGNETIC STRAP Z5020
Extra strength
MAGNETIC STRAP Z5004
Waterproof Box
For outdoor installation; IP65 compliant, Contact Hioki for a quotation.
CARRYING CASE C1001
Soft type, Includes compartment for options
CARRYING CASE C1002
Hard trunk type, Includes compartment for options
CARRYING CASE C1009
Bag type, Includes compartment for options
Verify the Energy Savings Created By Photovoltaic (PV) Systems
Measure the Transient Voltage in Glowing Fluorescent Lights
Measure Lightning-induced Voltage Dips in a Low-Voltage Circuit
Measure Voltage Drop Caused by Wiring Impedance
Measure Transient Voltage Waveforms
Measure Periodical Instantaneous Voltage Drops
Inspect the Stress on Factory UPS Caused by Voltage Dips
Verify Fault Ride-Through (FRT) Capabilities in Equipment and PV Systems
No results were found.