TEMP UNIT

8967

Measure temperature waveform by 16 bit resolution, isolated input

Key Features • 16-bit A/D high resolution measurement • Isolated input, up to 300 V AC/DC from the earth

Model No. (Order Code)

8967 For MR6000, MR8847A, MR8827, and similar products

Note: This module must be used with the Memory HiCorder. Input cords are not included. Please purchase them separately.

Guarantee3years
CE

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

Measurement functionsNumber of channels: 2, for temperature measurement with thermocouple (voltage measurement not available)
Input connectorsThermocouple input: plug-in connector,
Recommended wire diameter: single-wire, 0.14 to 1.5 mm2, braided wire 0.14 to 1.0 mm2 (conductor wire diameter min. 0.18 mm), AWG 26 to 16
Input impedance: min. 5 MΩ (with line fault detection ON/OFF),
Max. rated voltage to earth: 300 V AC, DC
(with input isolated from the unit, the maximum voltage that can be applied between input channel and chassis and between input channels without damage)
Temperature measurement range Note: Upper and lower limit values depend on the thermocouple10 °C/div (-100 °C to 200 °C), 50 °C/div (-200 °C to 1000 °C), 100 °C/div (-200 °C to 2000 °C), 3 ranges, full scale: 20 div,
Measurement resolution: 1/1000 of measurement range (using 16-bit A/D conversion and when installed in the 8847)
Thermocouple range (JIS C 1602-1995) (ASTM E-988-96)K: -200 to 1350 °C, J: -200 to 1100 °C, E: -200 to 800 °C, T: -200 to 400 °C, N: -200 to 1300 °C, R: 0 to 1700 °C, S: 0 to 1700 °C,
B: 400 to 1800 °C, W (WRe5-26): 0 to 2000 °C,
Reference junction compensation: internal/ external (switchable),
Line fault detection ON/OFF possible
Data refresh rate3 methods, Fast: 1.2 ms (digital filter OFF), Normal: 100 ms (digital filter 50/60 Hz), Slow: 500 ms (digital filter 10Hz)
Measurement accuracyThermocouple K, J, E, T, N: ±0.1 % of full scale ±1 °C (±0.1 % of full scale ±2 °C at -200 °C to 0 °C),
Thermocouple R, S, W: ±0.1 % of full scale ±3.5 °C (at 0 °C to 400 °C or less), ±0.1 % of full scale ±3 °C (at 400 °C or more)
Thermocouple B: ±0.1 % of full scale ±3 °C (at 400 °C or more),
Reference junction compensation accuracy: ±1.5 °C (added to measurement accuracy with internal reference junction compensation)
Dimensions and mass106 mm (4.17 in) W × 19.8 mm (0.78 in) H × 204.5 mm (8.05 in) D, 240 g (8.5 oz)
AccessoriesFerrite clamp × 2

Log into your myHioki account to access more technical documents and information where available.

Seminar Videos On Demand

No results were found.

Seminar Schedule

Registration Open

IEEE IFEEC 2019 - Singapore

Nov 25, 2019 - Nov 28, 2019

Registration Open

SPS - Nuremburg, Germany

Nov 25, 2019 - Nov 28, 2019

Catalogs

No results were found.

User Guides

No results were found.

Manuals

If you can not download, log into your myHioki account to access more technical documents and information where available.


Instruction Manual Japanese
English
Ver.09

Outline Drawings

If you can not download, log into your myHioki account to access more technical documents and information where available.



Ver.00

Technical Notes

No results were found.

Declaration of Conformity

No results were found.

Drivers, Firmware

No results were found.

Others

No results were found.

Applications

Gallery

No results were found.


  • Search


    Search Results Include Discontinued Products

    Login to myHIOKI

    Download

  • Ask

    • Ask Online

     

  • Quote

    • Request a Quote
    • Locate a Distributor

Related Products List