Exclusive Academic Offer >

WIRELESS UNIVERSAL UNIT

LR8511

Logging Multi-point Data Has Never Been So Easy with a Wireless Data Logger

Hioki Memory HiLoggers are high-speed data loggers for recording multiple channels of voltage, temperature, resistance or humidity signals, some models providing complete isolation between channels and strong noise resistance. The Hioki LR8511 is a wireless, 15-channel universal input module for measuring voltage, temperature, humidity or resistance, utilizing Bluetooth® wireless technology to send measured data to the Hioki LR8410 Wireless Logging Station. Key Features • This is a input module to capture logging data using Bluetooth® wireless technology. Install logging modules in hard-to-reach locations (over line-of-sight distances of up to 30 meters *1 ) (*1) The presence of obstructions may shorten this range • Choose an input module based on the parameters you wish to measure (15-channel type) • Easily add up to 7 input modules wirelessly to keep your environment free of tangled wires (for a total of up to 7 modules for the LR8410 main unit, max. 105 channels when using 15-channel modules) • 100 msec simultaneous sampling across all channels using rapid scanning method

Model No. (Order Code)

LR8511 For the LR8410

The LR8511 alone is not capable of making measurements. Wireless logging station Model LR8410-20 is necessary to measure. The main unit and input modules are not bundled with the Battery Pack Z1007. Thermocouples are not provided by HIOKI, and must be purchased from a separate vendor. *Models LR8512 to LR8515 may only be used in countries in which they have been certified. These products emit radio waves. Use of radio waves is subject to licensing requirements in certain countries. Use in countries or regions other than those listed above may constitute a violation of law, exposing the operator to legal penalties. For the latest information about countries and regions where wireless operation is currently supported, please visit the Hioki website.

Guarantee3years
Bluetooth
CE

Basic specifications

Supported modelModel LR8410-20
Control and communicationsBetween instrument and unit: Bluetooth® 2.1 + EDR, Communications range: 30 m (98.43 ft), Security: SSP
Measurement parameters[No. of channels] 15 analog channels; isolated scanning method input (4 terminals: push-button type)
[Voltage] ±10 mV to ±100 V, 1-5 V f.s., max. 500 nV resolution
[Temperature: Thermocouples] -200 ˚C to 2000 ˚C (depends on sensor), Thermocouples (K, J, T, or other), max. 0.01 ˚C resolution
[Temperature: Pt 100, JPt 100 sensor] -200 ˚C to 800 ˚C, max. 0.01 ˚C resolution (not isolated between channels)
[Resistance] 0 Ω to 200 Ω f.s., max. 0.5 mΩ resolution (not isolated between channels)
[Humidity] 5.0 to 95.0 % rh (use with optional sensor), 0.1 % rh resolution (not isolated between channels)
[Max. rated voltage between isolated input channels] 300 V DC
[Max. allowable input] ±100 V DC
[Max. rated voltage from isolated terminals to ground] 300 V AC, DC
Operating temperature-20 °C to +60 °C (-4 °F to 140 °F)
Power supply[AC adapter] Using the AC adapter Z1008 (100 to 240 V AC, 50/60 Hz), 23 VA Max. (including AC adapter), 7 VA Max. (exclusive of AC adapter)
[Internal battery] Using the Battery Pack Z1007 (optional accessory), 24 hours of continuous use (at 100 ms recording interval, 23 ˚C reference data), 120 hours of continuous use (at 1 minute recording interval, 23 ˚C reference data), 0.6 VA Max.
[External power] 10 to 28 V DC, 7 VA Max.
Dimensions and mass150 mm (5.91 in) W × 90 mm (3.54 in) H × 56 mm (2.20 in) D, 320 g (11.3 oz)
AccessoriesInstruction manual ×1, AC adapter Z1008 (with supplied power cord) ×1, Bracket ×1, M3×4 mm screw ×2

Countries and regions where wireless operation is currently supported (LR8511)Last update: Mar. 29, 2019

Wireless certificationJapan, United States, Canada, Austria, Belgium, Bosnia and Herzegovina, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey, United Kingdom, Thailand, Singapore, China, Taiwan, Indonesia, Australia, New Zealand, UAE, Chile, and Mexico
Exempt from the wireless regulationsViet Nam, Hong Kong, Macao, India, Russian Federation, Colombia, Pakistan, and Georgia

Log into your myHioki account to access more technical documents and information where available.

Seminar Videos On Demand

No results were found.

Seminar Schedule

Registration Open

Automotive Testing Expo - Stuttgart, Germany

May 21, 2019 - May 23, 2019

Catalogs

Catalog: WIRELESS LOGGING STATION LR8410 Download PDF  [5MB] English

User Guides

No results were found.

Manuals

If you can not download, log into your myHioki account to access more technical documents and information where available.


Instruction Manual Japanese
English
Ver.03
Precautions Concerning Use of Equipment that Emits Radio Waves Japanese
English
Ver.16

Outline Drawings

If you can not download, log into your myHioki account to access more technical documents and information where available.



Ver.04

Technical Notes

No results were found.

Declaration of Conformity

No results were found.

Drivers, Firmware

No results were found.

Others

No results were found.

Options

Optional sensors

HUMIDITY SENSOR Z2000

3 m (9.84 ft) length

Power supply

*AC adapter is bundled with the LR8410-20, LR8510/8511

BATTERY PACK Z1007

Li-ion, Charges while installed

AC ADAPTER Z1008

100 to 240V AC

Gallery

No results were found.


  • Search


    Search Results Include Discontinued Products

    Login to myHIOKI

    Download

  • Ask

    • Ask Online

     

  • Quote

    • Request a Quote
    • Locate a Distributor

Related Products List