LCR HiTESTER

3511-50

Compact, dual-band 120Hz/1kHz LCR Meter for Integration into Automated Production Lines

Hioki LCR Meters and Impedance Analyzers range from 1mHz to 3GHz devices to suit a wide range of applications in the testing of electronic components. The 3511-50 is a compact, general purpose LCR meter for on-board testing of capacitors and coils used in electrical equipment and devices such as automotive-related components. Key Features • High speed measurement: 5 ms (1 kHz) or 13 ms (120 Hz) • Built-in high-speed comparator • Measurement frequency: 1 kHz/120 Hz selectable • From minute measurement with a maximum resolution of 0.001 pF to high-capacity measurement up to 1 F (depending on measurement frequency)



Model No. (Order Code)

3511-50 Measurement frequencies: 120 Hz and 1 kHz

This product is not supplied with measurement probes or test fixtures. Please select and purchase the measurement probe or test fixture options appropriate for your application separately. For an RS-232C connection: A crossover cable for interconnection can be used. You can use the RS-232C CABLE 9637 without hardware flow control.

Guarantee3years
GPIB
RS232C
CE

Basic specifications (Accuracy guaranteed for 6 months, Post-adjustment accuracy guaranteed for 6 months)

Measurement parameters|Z|, θ, R, C, L, D (tanδ), Q
Measurement range|Z|, R: 10 mΩ to 200.00 MΩ θ: -90.00° to +90.00°
C (at 120 Hz): 9.40 pF to 999.99 mF, C (at 1 kHz): 0.940 pF to 99.999 mF
L (at 120 Hz): 14.00 µH to 200.00 kH, L (at 1 kHz): 1.600 µH to 20.000 kH
D: 0.0001 to 1.9900, Q: 0.85 to 999.99
Basic accuracy|Z| : ±0.08 % rdg. θ: ±0.05°
Measurement frequency120 Hz or 1 kHz
Measurement signal level50 mV, 500 mV, 1 V rms
Output impedance50 Ω
DisplayLED (5-digit display, full-scale count depends on range)
Measurement timeFast: 13 msec, Normal: 90 msec, Slow: 400 msec. (at 120 Hz)
Fast: 5 msec, Normal: 60 msec, Slow: 300 msec. (at 1 kHz)
DC biasDC voltage/DC current can be superimposed on the measurement signal.
(Requires optional unit and external constant voltage source/constant current source.)
FunctionsPanel save and load function, Comparator, External input/Output (EXT. I/O), GP-IB (option) or RS-232C interface
Power supplySelectable 100, 120, 220 or 240V AC ±10%, 50/60Hz, 20VA max.
Dimensions and mass210 mm (8.27 in) W × 100 mm (3.94 in) H × 168 mm (6.61 in) D, 2.5 kg (88.2 oz)
AccessoriesInstruction manual × 1, Power cord × 1, Spare fuse × 1

Log into your myHioki account to access more technical documents and information where available.

Seminar Videos On Demand

No results were found.

Seminar Schedule

Registration Open

ECCE 2019 - Baltimore, Maryland

Sep 29, 2019 - Oct 3, 2019

Catalogs

Catalog: LCR METER Series Download PDF  [4MB] English
Catalog: LCR HiTESTER 3511-50 Download PDF  [1MB] English
Catalog: SMD TEST FIXTURE IM9110 Download PDF  [1MB] English

User Guides

LCR Application Guide Download PDF  [4MB] English
Impedance Measurement Handbook Download PDF  [1MB] English

Manuals

If you can not download, log into your myHioki account to access more technical documents and information where available.


Instruction Manual English
Ver.13

Outline Drawings

If you can not download, log into your myHioki account to access more technical documents and information where available.



Ver.04

Technical Notes

No results were found.

Declaration of Conformity


Ver.11

Drivers, Firmware

No results were found.

Others

No results were found.

Options

Probe and Test fixtures

Note: The 9268-01 cannot use with the 3511-50, using with the 9268/9269, Not CE marked

SMD TEST FIXTURE IM9100

• High-precision four-terminal measurement • For direct connection meters • Test SMDs with electrodes on the bottom

Learn more

4-TERMINAL PROBE 9140

DC to 100 kHz, 1 m (3.28 ft) length, impedance characteristics of 75 Ω

CONNECTION CORD 9165

Cord has metallic BNC connectors at both ends, use at metallic terminal, 1.5 m (4.92 ft) length

CONNECTION CORD 9166

Metal BNC to clip, 1.5 m (4.92 ft) length

TEST FIXTURE 9261

DC to 8 MHz, 1 m (3.28 ft) length, impedance characteristics of 75 Ω

TEST FIXTURE 9262

Direct connection type, DC to 8 MHz, measurable conductor diameter: ø0.3 (0.01 in) to 2 mm (0.08 in)

SMD TEST FIXTURE 9263

Direct connection type, DC to 8 MHz, Test sample dimensions:1 mm (0.04 in) to 10 mm (0.39 in)

DC BIAS VOLTAGE UNIT 9268

42 Hz to 5 MHz, Max. allowable voltage: ± 40 V DC

DC BIAS CURRENT UNIT 9269

42 Hz to 100 kHz, Max. allowable current: ±2A DC

SMD TEST FIXTURE 9677

Direct connection type, For measuring SMDs with electrodes on the side; DC to 120 MHz, test sample dimensions: 3.5 mm ±0.5 mm (0.14 in ±0.02 in)

SMD TEST FIXTURE 9699

Direct connection type, For measuring SMDs with electrodes on the bottom; DC to 120 MHz, test sample dimensions: 1.0 mm (0.04 in) to 4.0 mm (0.16 in) wide, max. 1.5 mm (0.06 in) high

CONTACT TIPS IM9901

To replace the tip on the L2001, regular size, bundled with the L2001

CONTACT TIPS IM9902

To replace the tip on the L2001, small size

PINCHER PROBE L2001

• 2-terminal design • Tip electrode spacing: 0.3 (0.01 in) to 6 mm (0.24 in)

Learn more

SMD TEST FIXTURE IM9110

• High-precision two-terminal fixture • For direct connection two-terminal measurement meters • High reproducibility with advanced contact technology

Learn more

PC communication

GP-IB CONNECTOR CABLE 9151-02

2 m (6.56 ft) length

GP-IB INTERFACE 9518-01

Built into rear panel

Printer options

RECORDING PAPER 1196

For the Printer 9442, 112 mm (4.41 in) × 25 m (82.03 ft), 10 rolls/set

PRINTER 9442

For printing numerical values 112 mm (4.41 in) paper width, not CE marked

AC ADAPTER 9443-02

For the Printer 9442, EU type

CONNECTION CABLE 9444

9 pin - 9 pin straight, 1.5 m (4.92 ft) length

Gallery

No results were found.


  • Search


    Search Results Include Discontinued Products

    Login to myHIOKI

    Download

  • Ask

    • Ask Online

     

  • Quote

    • Request a Quote
    • Locate a Distributor

Related Products List


​​