CLAMP ON PROBE
3275
Wideband Current Probe for Oscilloscopes
Hioki flat bandwidth current probes are best-in-class current sensors for use with Memory HiCorders and high performance oscilloscopes. The 3275 supports wide DC to 2 MHz bandwidth signals and 500A of continuous high input. The probe is designed with an electrostatic shield to reduce the effects of electric fields, making it ideal for measuring in environments in which the probe will be subjected to the effects of nearby magnetic fields, such as locations with high-voltage switching control equipment such as an inverter or motor. Key Features • Waveform observation across a wide band from DC to MHz • Connects directly to oscilloscope or Memory HiCorder BNC input terminal *1 *1: Connecting the probe's metal BNC terminal to a Memory HiCorder’s plastic BNC terminal may distort or damage the plastic terminal. To avoid damage, please connect and disconnect the probe cable straight to the BNC terminal of the waveform monitoring equipment.
3275 | DC to 2 MHz, 500 Arms |
---|
Note: Use the Power Supply 3269/3272 for general measurements or when power is not available from the Memory Hicorder. When performing continuous measurements, be aware of offset voltage drift.
Wideband current sensors use the "zero flux method (Hall element detection type)" to measure. High-frequency currents are detected with the winding (CT method), and low frequency currents including DC are detected with the "Hall element." ● Hall element detection Hall element detection is characterized by a simple structure and a sensor section that can easily be downsized. Hioki combines our own proprietary thin-film Hall elements with the zero flux method to deliver sensors that can conduct measurements over a wide range of frequencies, from DC to MHz bands Ideal for waveform observations using a MEMORY HiCORDER or oscilloscope, Hall element detection achieves a high S/N ratio in the wideband range, making them particularly well-suited for design verification of electronic circuitry such as high-speed signal circuits. ● Zero flux method The zero flux method is a measurement method used in both high-accuracy and wideband sensors. As the principles the sensor is based on give it both low operating magnetic flux level and low insertion impedance, it is characterized by its lack of influence on the measured object and low instrument loss.
Frequency bandwidth | DC to 2 MHz (-3 dB) |
---|---|
Rise time | 175 ns or shorter |
Noise level | 25 mA rms max. (bandwidth limited to 20 MHz) |
Continuous allowable input | 500 A rms (requires derating at frequency) |
Max. allowable peak input | 700 A peak (non continuous) |
Amplitude accuracy (30 min. after power-on, after degaussing and zero-adjustment) | ±1.0 % rdg. ±5 mV f.s. (DC, 45 to 66 Hz, 0 to 500 A rms) ±2.0 % rdg. (DC, 45 to 66 Hz, 500 A to 700 A peak) |
Output rate | 0.01 V/A (The output of this probe is internally terminated, so connect to voltage input equipment with high input impedance such as 1MΩ) |
Measurable conductors | Insulated conductor |
Core diameter | φ 20 mm (0.79 in) |
Power supply | ±12 V ±0.5 V, 7.2 VA max. |
Dimensions and mass | 176 mm (6.93 in)W × 69 mm (2.72 in)H × 27 mm (1.06 in)D, 520 g (18.3 oz) Sensor cable BNC terminal: 2 m (6.56 ft), Power cable: 1 m (3.28 ft) |
Accessories | Instruction manual ×1, Carrying case × 1 |
Log into your myHioki account to access more technical documents and information where available.
No results were found. |
No results were found. |
Catalog: HIGH ACCURACY / WIDEBAND CURRENT SENSOR Series CT686x, CT687x, CT684x | Download PDF [6MB] |
English |
Catalog: CURRENT PROBE series CT6700, CT6701, 3273-50, 3274, 3275, 3276 | Download PDF [4MB] |
English |
No results were found. |
If you can not download, log into your myHioki account to access more technical documents and information where available.
CLAMP ON PROBE 3274,3275 [3MB] |
Instruction Manual |
English |
Ver.05 |
If you can not download, log into your myHioki account to access more technical documents and information where available.
CLAMP ON PROBE 3275 [101KB] |
Ver.03 |
Developing a Thin-film Low-noise Hall Element for Use in Current Probes [611KB] |
High-precision, Wideband, Highly Stable Current Sensing Technology [6MB] |
|
Ver.09 |
No results were found. |
No results were found. |
POWER SUPPLY 3269
• 2 channels for CT6710 series or 4 channels for CT6700 and 3270 series • ±12 V output