DC SIGNAL SOURCE

SS7012

DC Voltage and Current Signal Generator and Tester for Routine Maintenance of Standard Devices

The Hioki SS7012 is a compact DC signal source and calibrator that is used to perform maintenance or loop tests of instrumentation systems and can be operated from a computer via a USB cable. It can also be used to calibrate thermometers and measure DC voltage and DC current. Key Features • Improve stability and reduce calibration costs compared with the previous HIOKI model • For instrumentation systems (4 - 20 mA) and loop testing • Check temperature control equipment and electric distribution • 8 types of thermocouples to test thermoelectric power generation • Ideal for electrical device evaluating and routine maintenance of production equipment such as calibrators • Use the max. 25 mA DC sink as an electric load



Model No. (Order Code)

SS7012

Use of the AC Adapter and /or rechargeable batteries and dedicated charger is recommended

Guarantee3years
USB1
Communication only
CE

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)[Generation functions]

Circuit methodBipolar sink and source
Constant voltage2.5 V: 0 to ±2.5000 V (±0.03 % of setting ±300 μV, 100 μV resolution)
25 V: 0 to ±25.000 V (±0.03 % of setting ±3 mV, 1 mV resolution)
Constant current25 mA: 0 to ±25.000 mA (±0.03 % of setting ±3 μA, 1 μA resolution)
Thermoelectric power generationK: at TC: 0 ˚C, -174.0 to 1372.0 ˚C (±0.05 % of setting ±0.5 ˚C, 0.1 ˚C resolution), Other types: E, J, T, R, S, B, N selectable
Thermoelectric power generationK: at TC: RJ, -174.0 to 1372.0 ˚C (±0.05 % of setting ±1.0 ˚C, 0.1 ˚C resolution), Other types: E, J, T, R, S, B, N selectable
Standard resistance (Rs)100 Ω (±0.2 Ω)
Automatic generationNumber of memory steps: 20, Interval time: 1 to 99 sec (at CV, CC, TC mode)

[Measurement functions]

Voltage2.5 V: 0 to ±2.8000 V (±0.03 % rdg. ±300 μV, 100 μV resolution, 1 MΩ input resistance)
25 V: 0 to ±28.000 V (±0.03 % rdg. ±3 mV, 1 mV resolution, 1 MΩ input resistance)
Current25 mA: 0 to ±28.000 mA (±0.03 % rdg. ±3 μA, 1 μA resolution, smaller than 30 Ω input resistance)
Temperature-25.0 to 80.0 ˚C (±0.5 ˚C at 23 ±5 ˚C, 0.1 ˚C resolution, use with the RJ sensor 9184)
Sampling rateApprox. 1.67 times/sec

[General functions]

Additional functionsZero adjustment, Overflow display, USB communication, Monitor
Power supplyAC adapter 9445-02/-03 (100 to 240 V AC 50/60 Hz, 9 VA),
Ni-MH battery HR6 × 4, 6 VA, (fully charged 2500 mAh Ni-MH batteries: 170 minutes continuous use), or LR6 (AA) alkaline battery × 4, 6 VA
Dimensions and mass104 mm (4.09 in) W × 180 mm (7.09 in) H × 58 mm (2.28 in) D, 660 g (23.3 oz) (including LR6 × 4 batteries)
AccessoriesInput cord 9168 ×1, Test lead L9170-10 ×1, Fuse ×1, LR6 (AA) alkaline battery ×4, Instruction manual ×1

Log into your myHioki account to access more technical documents and information where available.

Seminar Videos On Demand

No results were found.

Seminar Schedule

No results were found.

Catalogs

Catalog: DC SIGNAL SOURCE SS7012 Download PDF  [1MB] English

User Guides

No results were found.

Manuals

If you can not download, log into your myHioki account to access more technical documents and information where available.


Remote Operation Manual English
Ver.01
Remote Operation Manual Simplified Chinese
Ver.00
Instruction Manual Simplified Chinese
Ver.06
Instruction Manual English
Ver.09

Outline Drawings

If you can not download, log into your myHioki account to access more technical documents and information where available.



Ver.03

Technical Notes

No results were found.

Declaration of Conformity


Ver.08

Drivers, Firmware

DC SIGNAL SOURCE SS7012 Sample Software  Freeware version 1.02 

Others

No results were found.

Options

Cables

*Bundled accessories

TEST LEAD L9170-10

70 cm (2.30 ft) length

INPUT CORD 9168

70 cm (2.30 ft) length

Options

Commercially available rechargeable batteries (AA Ni-MH batteries ×4) may also be used to power the SS7012. Using locally purchased rechargeable batteries and dedicated battery chargers is recommended; however, HIOKI will not be able to guarantee operatin

TEMPERATURE PROBE 9184

For reference contact compensation

CARRYING CASE 9380

For storing the main body only, soft type

AC ADAPTER 9445-02

For USA, 100 to 240 V AC, 9 V/ 1 A

AC ADAPTER 9445-03

For EU, 100 to 240 V AC, 9 V/ 1 A

CARRYING CASE 9782

Includes compartment for options, resin-coated

COMMUNICATION PACKAGE SS9000

USB cable, USB driver software included

Gallery

No results were found.


  • Search


    Search Results Include Discontinued Products

    Login to myHIOKI

    Download

  • Ask

    • Ask Online

     

  • Quote

    • Request a Quote
    • Locate a Distributor

Related Products List


​​