Wide Bandwidth. Wide Spectrum 6ch Power Meter for Comprehensive Device Assessment

Hioki benchtop power meters and power analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy. The 3193-10 is a 6-channel power meter for testing any type of circuit ranging from single-phase lines to three-phase four-wire lines. Based on the voltage, current, and active power measurements, the power meter calculates and displays reactive power, apparent power, power factor, phase angle, and efficiency. It also provides a wide range of measurement functions including frequency measurement function, peak measurement function, current integration, active power integration, analog outputs, monitor outputs. Key Features • A rich assortment of measurement functions including voltage, current, power, waveform peak value and efficiency • High-precision with basic accuracy of ±0.1 %, high-speed response of 0.1 s • Measure up to six circuits simultaneously • Select from 3 types of input units

Model No. (Order Code)

3193-10 Main unit only, no FDD

Note: Main unit 3193-10 cannot operate alone - please purchase an input unit Model 9600 to 9605 for factory installation prior to shipment. All subsequent input unit replacements or expansions must be conducted at HIOKI for an additional service charge. Voltage input code is not included in the input unit of 9600 to 9602. Clip type lead etc. Please consult as necessary.

Guarantee3years
GPIB
RS232C
TrueRMS
CE

Key Features

• A rich assortment of measurement functions including voltage, current, power, waveform peak value and efficiency • High-precision with basic accuracy of ±0.2 %, high-speed response of 0.1 s • Measure up to six circuits simultaneously • Select from 3 types of input units


■ Basic specifications (Accuracy guaranteed for 6 months, Post-adjustment accuracy guaranteed for 6 months)

Measurement linesSingle-phase 2-wire, single-phase 3-wire, three-phase 3-wire, and three-phase 4-wire systems
Measurement items[Using the optional 9600, 9601, 9602]
Voltage, current, voltage/current peak, active power, reactive power, apparent power, power factor, phase angle, frequency, current integration, power integration, load rate, efficiency
[Using the optional 9603, added function]
Voltage, torque, rotation, frequency, motor output
[Using the optional 9605, added function]
Harmonic measurement, waveform, voltage fluctuation / flicker measurement function
Measurement range (using the 9600)[Voltage] 6/ 15/ 30/ 60/ 150/ 300/ 600/ 1000 V
[Current] 200/ 500 mA, 1/ 2/ 5/ 10/ 20/ 50 A
[Power] 1.2 W to 150 kW
(Depends on measurement mode and combination of voltage and current range)
[Frequency] 50/ 500/ 5 k/ 50 k/ 2 MHz
Basic accuracy (Active power)±0.1 % rdg. ±0.1 % f.s. (45 Hz to 66 Hz, using the 9600)
Display refresh rate8 times /s
Frequency characteristics[Using the 9600] DC, 0.5 Hz to 1 MHz
[Using the 9601] 5 Hz to 100 kHz
[Using the 9602] DC, 0.5 Hz to 200 kHz
FunctionsWaveform peak measurement, Efficiency measurement, D/A output, External control, Scaling, Averaging, Back up function, PM measurement at motor output (using the optional 9603), etc,.
InterfacesRS-232C, GP-IB standard
Power supply100/ 120/ 200/ 230 V AC, switched automatically, 50/60 Hz, 150 VA max.
Dimensions and mass430 mm (16.93 in) W × 150 mm (5.91 in) H × 370 mm (14.57 in) D, 15 kg (529.1 oz) (at options installed)
AccessoriesInstruction manual ×1, Power cord ×1, Connector ×1

Log into your myHioki account to access more technical documents and information where available.

Seminar Videos On Demand

No results were found.

Seminar Schedule

Registration Open

SPS IPC Drives - Nuremberg Messe

Nov 27, 2018 - Nov 29, 2017

Catalogs

Catalog: POWER HiTESTER 3193-10 Download PDF  [2MB] English

User Guides

No results were found.

Manuals

Instruction Manual English
Ver.15

Outline Drawings


Ver.00

Technical Notes

No results were found.

Declaration of Conformity


Ver.04

Drivers, Firmware

No results were found.

Others

No results were found.

Options

Factory-installed options

* Input modules are factory-installed options, must specify when ordering

* Use the same input unit for a particular measurement line.
* When selecting the 9602 Input Unit, be sure to also purchase the appropriate clamp sensor.

AC/DC DIRECT INPUT UNIT 9600

6 V to 1 kV, 200 mA to 50 A

AC DIRECT INPUT UNIT 9601

60 V to 1 kV, 200 mA to 50 A

AC/DC CLAMP INPUT UNIT 9602

6 V to 600 V, 500 mA to 500 A, * Depends on clamp on sensor in use

EXTERNAL SIGNAL INPUT UNIT 9603

For the 3193, 3193-10 only, Pulse, DC voltage input, 2 channels input

PRINTER UNIT 9604

Data print, screen copy, built-in unit type, not CE Marked

Up to 200 A (High precision)

* Model CT6863 is recognized as the UNIVERSAL CLAMP ON CT Model 9278 by Model 3193/ 3193-10/ 3194, but operability is supported.

* In order to use AC/DC CURRENT SENSOR Model CT6862 with Model 3193/ 3194, a firmware upgrade of Model 3193/ 3194 is required.

AC/DC CURRENT SENSOR CT6862

• DC to 1MHz (Phase: up to 300kHz) • Rated 50A AC/DC • φ 24 mm (0.94 in) core dia.

Learn more

AC/DC CURRENT SENSOR CT6863

• DC to 500kHz (Phase: up to 300kHz) • Rated 200A AC/DC • φ 24 mm (0.94 in) core dia.

Learn more

AC/DC CURRENT PROBE CT6841

• DC to 1MHz (Phase: up to 300kHz) • Rated 20A AC/DC • φ 20 mm (0.79 in) core dia.

Learn more

AC/DC CURRENT PROBE CT6843

• DC to 500kHz (Phase: up to 300kHz) • Rated 200A AC/DC • φ 20 mm (0.79 in) core dia.

Learn more

CLAMP ON SENSOR 9272-10

• 1Hz to 100kHz (Phase: 5Hz to 50kHz) • Rated 20A/200A AC/DC • φ 46 mm (1.81 in) core dia.

Learn more

Up to 500 A (High precision)

AC/DC CURRENT SENSOR 9709

• DC to 100kHz (Phase: up to 100kHz) • Rated 500A AC/DC • φ 36 mm (1.42 in) core dia.

Learn more

AC/DC CURRENT PROBE CT6844

• DC to 200kHz (Phase: up to 200kHz) • Rated 500A AC/DC • φ 20 mm (0.79 in) core dia.

Learn more

AC/DC CURRENT PROBE CT6845

• DC to 100kHz (Phase: up to 100kHz) • Rated 500A AC/DC • φ 50 mm (1.79 in) core dia.

Learn more

Up to 1000 A (High precision)

*When using the CT6865/CT6846, manual settings are required on the main device.

AC/DC CURRENT SENSOR CT6865

• DC to 20kHz (Phase: up to 1kHz) • Rated 1000A AC/DC • φ 36 mm (1.42 in) core dia.

Learn more

AC/DC CURRENT PROBE CT6846

• DC to 20kHz (Phase: up to 20kHz) • Rated 1000A AC/DC • φ 50 mm (1.79 in) core dia.

Learn more

ME15W (12 pin) - PL23 (10 pin) conversion

*When using ME15W terminal sensors with the “-05” suffix, the CT9901 is required as a connector adapter.

*When using ME15W terminal sensors CT6865-05 and CT6846-05, connection via the CT9901 and manual settings are required on the main device.

CONVERSION CABLE CT9901

ME15W (12 pin) to PL23 (10 pin) connector

Voltage measurement

MAGNETIC ADAPTER 9804

Attaches to the tip of voltage cord, φ11 mm (0.43 in), compatible M6 pan screws

VOLTAGE CORD L9438-50

1000 V specifications, Black/ Red, 3 m (9.84 ft) length, Alligator clip ×2

GRABBER CLIP 9243

Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V

MAGNETIC ADAPTER 9804-01

Attaches to the tip of cord, red ×1, φ11 mm (0.43 in)

MAGNETIC ADAPTER 9804-02

Attaches to the tip of cord, black ×1, φ11 mm (0.43 in)

PC communications

RS-232C CABLE 9637

For the PC, 9 pin - 9 pin, cross, 1.8 m (5.91 ft) length

GP-IB CONNECTOR CABLE 9151-02

2 m (6.56 ft) length

Printer option

RECORDING PAPER 9232

For the Printer option 9604, 74 mm (2.91 in) × 10 m (32.81 ft), 10 rolls/set

Applications

Gallery

No results were found.


  • Search


    Search Results Include Discontinued Products

    Login to myHIOKI

    Download

  • Ask

    • Ask Online

     

  • Quote

    • Request a Quote
    • Locate a Distributor

Related Products List